69-0153—3
2
TS86A POWERPILE
®
THERMOSTAT
Mounting Wallplate on Outlet Box
Use cover ring, TS86A Wallplate Assembly and screws as
shown in Fig. 3.
1. Place the cover ring on the outlet box with the cable
entrance holes toward the bottom.
2. Pull the thermostat cable through the bottom hole.
3. Align the diamonds vertically on the cover ring and
secure with the screws provided.
NOTE:
The side reading Made in U.S.A. must be
against the wall.
4. Position the wallplate assembly and pull the
thermostat cable through the cable entrance hole.
5. Mount wallplate with the screws provided. Tighten
screws after the wallplate is leveled. See Fig. 1 for
leveling instructions.
SPIRIT
LEVEL
DIAMOND
GUIDES (2)
LEVELING
POSTS (2)
MOUNTING
SLOTS
M3831
VERTICAL
PLUMB LINE
OPENING FOR
THERMOSTAT
WIRING
R
W
Y
1
CONNECT WIRING TO R AND W TERMINALS FOR
750 mV SYSTEMS. CONNECT TO R AND Y FOR
250 OR 500 mV SYSTEMS.
1
WALL
1
USE WALLPLATE FOR HEAT APPLICATIONS.
127293 COVER
RING (OPTIONAL)
THERMOSTAT CABLE
ENTRANCE HOLE
NO. 4 X 1 INCH SHEET
METAL SCREWS (2)
WALLPLATE
M3829A
MOLDED
LEVELING
POST
Fig. 2. Mounting wallplate to wall.
Fig. 3. Mounting wallplate to outlet box.
OUTLET BOX
127293
COVER RING
1
CAPTIVE
SCREWS (3)
THERMOSTAT CABLE
ENTRANCE HOLE
TS86A
(COVER RING
REMOVED)
IF OUTLET BOX IS HORIZONTAL, MOUNT COVER RING IN POSITION
SHOWN, BUT FASTEN WITH SCREWS THROUGH "A".
M3826
Wiring
IMPORTANT
1. Never use any source of power other than a self-
powered millivoltage pilot generator system.
Refer to Fig. 4. Connect a 750 millivolt system to
R and W terminals at wallplate. Connect a 250
or 500 millivolt system to R and Y terminals
at wallplate.
2. This thermostat has a fixed anticipation heater
properly sized for use with self-generating
Powerpile systems. It should not be changed.
3. Use the T87, not the TS86, in systems where the
millivoltage gas valve is controlled through a
switching relay.
All wiring must comply with local codes and ordinances for
wire size and voltage. See Fig. 4 for typical millivolt
hookup.
Fig. 1. Leveling wallplate with spirit level or plumb line.