background image

ER150 AND ER200 Perfect Window™ FRESH AIR VENTILATION SYSTEMS

9

69-1563-1

Perfect Climate® Control

Describing Perfection

The most convenient, most energy efficient, cleanest, healthiest and most comfortable 

indoor environment, possible today! Perfect climate is achieved when the six core 
components of your homes climate system work together:

• optimal efficiency of heating and cooling equipment
• precise, programmable temperature control

• effective indoor air quality control

• controlled humidity
• proper ventilation and air distribution

• zone control for personalized room-to-room temperature control.

Products for a Perfect Climate® Home

HEATING AND COOLING SYSTEM

This is the workhorse of your indoor climate system. Have your local heating/cooling 

contractor tune up your system annually for comfort, safety and most economical 

operation. If your heating equipment is old, think about replacing it with a modern and 
improved unit. Recent advances in product technology have substantially increased 

efficiency of equipment. Improved performance often pays back much of the cost of 

installation within a few short years.

• Honeywell Perfect Window™ Fresh Air Ventilation System

• Honeywell Perfect Climate Comfort Center™ control or Chronotherm® IV 

programmable thermostat.

• Honeywell F35 media air cleaner or 

F50 electronic air cleaner.

• Honeywell humidistat and 

humidifier.

• Honeywell digital fan timer.

CONDITIONED 

AIR

CONDITIONED 

AIR

RETURN AIR

REGISTER

SUPPLY AIR

REGISTER

STALE AIR

EXHAUST

FRESH AIR 

INTAKE

PERFICT

WINDOW™
FRESH AIR

VENTILATION

SYSTEM

HONEYWELL 
ELECTRONIC AIR CLEANER

OPTIMAL

EFFICIENCY

FORCED AIR

FURNACE

FRESH 
AIR TO

HOME

HUMIDIFIER

OPTIMAL

EFFICIENCY AIR

CONDITIONER

OR HEAT PUMP

THE

HONEYWELL

PERFECT WINDOW™

FRESH AIR VENTILATION SYSTEM 

IS ONE PART OF A PERFECT CLIMATE

®

   

INDOOR ENVIRONMENT THAT PROVIDES TOTAL 

INDOOR COMFORT.  IT MAKES YOU FEEL BETTER, AND 

ALLOWS YOU TO LIVE AND WORK IN A MORE 

COMFORTABLE ENVIRONMENT. 

COLD AIR

RETURN

STALE

 AIR FROM

BATHS

®

M11703

How it works...

HONEYWELL
HUMIDISTAT

DIGITAL

ELECTRONIC

TIMER

HONEYWELL

CHRONOTHERM®   lV

PROGRAMMABLE

THERMOSTAT

FAN TIMER

20

40

60

Содержание PERFECT WINDOW ER150C

Страница 1: ... U S Registered Trademark Copyright 2002 Honeywell All Rights Reserved 69 1563 1 ER150C and ER200C Perfect Window Fresh Air Ventilation Systems OWNER S MANUAL M11706 ...

Страница 2: ...eling right at home 3 The Perfect Window Fresh Air Ventilation System consists of 3 Operating your Fresh Air Ventilation System 4 Getting the most from your Fresh Air Ventilation System 6 Maintenance Instructions for your Fresh Air Ventilation System 6 Perfect Climate Control 9 Troubleshooting 10 Warranty 11 ...

Страница 3: ...coming critical to feeling right at home The Honeywell Perfect Window Fresh Air Ventilation System removes stale unhealthy air and replaces it with a stream of fresh air Its powerful centrifugal blowers bring fresh air into your home and at the same time exhaust stale air in an equal amount Both incoming and outgoing airstreams pass through a energy transfer core where both the heat and the moistu...

Страница 4: ... core removes easily for cleaning 4 Controls Speed Control Easy operation simply rotate the Perfect Window ventilator fan speed control to your desired setting Operating your Fresh Air Ventilation System Changing Fan Speed The control fan speed is conveniently located on the ventilator The rotary fan speed control knob can be manually set from the off standby position through speeds 1 to 4 Note th...

Страница 5: ...he Ventilate key See the Perfect Climate Comfort Center Owner s Guide form 69 0891 for complete instructions TIMER For your convenience Honeywell provides an optional timer control that can fit a wide variety of needs for example exhaust humid air from the bathroom or kitchen see the timer instructions for selection and part numbers WALL SWITCH A wall switch can also be used to switch your ventila...

Страница 6: ...TO HIGH SPEED BY 1 selecting the highest speed on the ventilator or 2 if the system includes an optional remote control switch it to the ON position Maintenance Instructions for your Fresh Air Ventilation System WARNING Electrical Shock Hazard Can cause personal injury or equipment damage Disconnect power supply before performing maintenance The Perfect Window Fresh Air Ventilation System must be ...

Страница 7: ... Core Maintenance section for cleaning instructions 2 Remove filter clip 3 Remove filters from the core and rinse with water or a combination of soap and water Do not clean in a dishwasher 4 After cleaning place filters wet or dry back in their position and reattach the retaining clip CORE IMPORTANT Do not wash the core with water or other fluids Clean the core twice each year using only a vacuum ...

Страница 8: ...r corners in place and the core straight and even push on the core center until the core slides to the back of the cabinet NOTE The core is designed to appear to protrude from the cabinet approximately 1 8 in 3mm so the access door fits tightly against the core GENERAL MAINTENANCE Twice a year wipe the inside of the cabinet with a damp cloth to remove dirt bugs and debris that can be present FANS ...

Страница 9: ...uct technology have substantially increased efficiency of equipment Improved performance often pays back much of the cost of installation within a few short years Honeywell Perfect Window Fresh Air Ventilation System Honeywell Perfect Climate Comfort Center control or Chronotherm IV programmable thermostat Honeywell F35 media air cleaner or F50 electronic air cleaner Honeywell humidistat and humid...

Страница 10: ...dehumidistat is set to OFF or the humidity setting is higher than room humidity door Is not closed properly the safety interlock switch will keep the ventilator off Check that the access door is firmly closed and latched refer to operating instructions call your installation contractor for service Lack of Speed Control let the remote device continue its time setting or manually adjust it to gain s...

Страница 11: ...he product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states d...

Страница 12: ...tomation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...