ER150 AND ER200 Perfect Window™ FRESH AIR VENTILATION SYSTEMS

7

69-1563-1

WARNING

Carbon Monoxide Hazard.

Can cause personal injury or equipment damage.

Hood blockage can cause a change of pressure in building which can lead to 
possible spillage from combustible appliances.

AIR FILTERS

Air filters should be cleaned twice a year. The standard filters supplied with your 
ventilator are removable and washable.

1.

Open access door and slide out core. Refer to Core Maintenance section for 
cleaning instructions.

2.

Remove filter clip.

3.

Remove filters from the core and rinse with water or a combination of soap and 
water. Do not clean in a dishwasher.

4.

After cleaning, place filters (wet or dry) back in their position and reattach the 

retaining clip.

CORE 

IMPORTANT

Do not wash the core with water or other fluids.

Clean the core twice each year using only a vacuum cleaner.

1.

Open the access door and carefully grip the ends of the core and pull evenly out-
ward. The core can be snug, but it will slide out of the cabinet.

NOTE: Do not handle the fins because damage can occur.

CORE GUIDE CHANNEL

FILTER

FILTER CLIP

M11899

Содержание PERFECT WINDOW ER150C

Страница 1: ... U S Registered Trademark Copyright 2002 Honeywell All Rights Reserved 69 1563 1 ER150C and ER200C Perfect Window Fresh Air Ventilation Systems OWNER S MANUAL M11706 ...

Страница 2: ...eling right at home 3 The Perfect Window Fresh Air Ventilation System consists of 3 Operating your Fresh Air Ventilation System 4 Getting the most from your Fresh Air Ventilation System 6 Maintenance Instructions for your Fresh Air Ventilation System 6 Perfect Climate Control 9 Troubleshooting 10 Warranty 11 ...

Страница 3: ...coming critical to feeling right at home The Honeywell Perfect Window Fresh Air Ventilation System removes stale unhealthy air and replaces it with a stream of fresh air Its powerful centrifugal blowers bring fresh air into your home and at the same time exhaust stale air in an equal amount Both incoming and outgoing airstreams pass through a energy transfer core where both the heat and the moistu...

Страница 4: ... core removes easily for cleaning 4 Controls Speed Control Easy operation simply rotate the Perfect Window ventilator fan speed control to your desired setting Operating your Fresh Air Ventilation System Changing Fan Speed The control fan speed is conveniently located on the ventilator The rotary fan speed control knob can be manually set from the off standby position through speeds 1 to 4 Note th...

Страница 5: ...he Ventilate key See the Perfect Climate Comfort Center Owner s Guide form 69 0891 for complete instructions TIMER For your convenience Honeywell provides an optional timer control that can fit a wide variety of needs for example exhaust humid air from the bathroom or kitchen see the timer instructions for selection and part numbers WALL SWITCH A wall switch can also be used to switch your ventila...

Страница 6: ...TO HIGH SPEED BY 1 selecting the highest speed on the ventilator or 2 if the system includes an optional remote control switch it to the ON position Maintenance Instructions for your Fresh Air Ventilation System WARNING Electrical Shock Hazard Can cause personal injury or equipment damage Disconnect power supply before performing maintenance The Perfect Window Fresh Air Ventilation System must be ...

Страница 7: ... Core Maintenance section for cleaning instructions 2 Remove filter clip 3 Remove filters from the core and rinse with water or a combination of soap and water Do not clean in a dishwasher 4 After cleaning place filters wet or dry back in their position and reattach the retaining clip CORE IMPORTANT Do not wash the core with water or other fluids Clean the core twice each year using only a vacuum ...

Страница 8: ...r corners in place and the core straight and even push on the core center until the core slides to the back of the cabinet NOTE The core is designed to appear to protrude from the cabinet approximately 1 8 in 3mm so the access door fits tightly against the core GENERAL MAINTENANCE Twice a year wipe the inside of the cabinet with a damp cloth to remove dirt bugs and debris that can be present FANS ...

Страница 9: ...uct technology have substantially increased efficiency of equipment Improved performance often pays back much of the cost of installation within a few short years Honeywell Perfect Window Fresh Air Ventilation System Honeywell Perfect Climate Comfort Center control or Chronotherm IV programmable thermostat Honeywell F35 media air cleaner or F50 electronic air cleaner Honeywell humidistat and humid...

Страница 10: ...dehumidistat is set to OFF or the humidity setting is higher than room humidity door Is not closed properly the safety interlock switch will keep the ventilator off Check that the access door is firmly closed and latched refer to operating instructions call your installation contractor for service Lack of Speed Control let the remote device continue its time setting or manually adjust it to gain s...

Страница 11: ...he product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states d...

Страница 12: ...tomation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Отзывы: