TechnIcAL DATA

Power supply 

Phc system (Phc bus)

Nom. 24 V DC

21-28 V  DC (ripple voltage 5 %)

own consumption

approx. 15-110 mA (after input switching)

Line lengths of the 

external inputs

maximum 25 m at 24V (

I

0–

I

3)

maximum 5 m at 5V (

I

4–

I

7)

connection 

possibilities

4 inputs (

I

0–

I

3) for buttons without LED 

4 inputs (

I

4–

I

7) for buttons with LED

1 input for switch (I0)

1 input for 24 V motion detector (

I

3)

coding

DIP switch, 5-pin (Module address)

connecTIon exAMPLes

0V

1 2 3 4 5

I

0

I

1

I

2

I

3

0V

I

6

I

7

I

5

I

4

+24V

+ A

-B

0 V

U

S

P

H

C

-B

ON

DIP

940/24 EM RÜ o.T.

LED

a) In-wall module 

  with eight 

  external buttons

Button 550

LeD/Phc

Phc bus

941 UP o.A.

+24V

+A

-B

0V

TOP

I0

0V

I2

I3

I1

1 2 3 4 5

0V

I

7

I

6

I

5

I

4

1 2 3 4 5

I

0

I

1

I

2

I

3

0V

I

6

I

7

I

5

I

4

+24V

+ A

-B

0 V

U

S

P

H

C

-B

ON

DIP

940/24 EM RÜ o.T.

LED

b) In-wall module with additional in-wall button module

Quadruple button

941 uP o.A.

Phc bus

WArrAnTy conDITIons

These operating instructions are an integral part of both the device and our terms of 

warranty. They must be handed over to the user. The technical design of the appliance 

is  subject  to  change  without  prior  notification. 

PEHA

 products are manufactured 

and quality-checked with the latest technology according to applicable national and 

international regulations. Nevertheless, if a product should exhibit a defect, 

PEHA

 

warrants to make remedy as follows (regardless of any claims against the dealer to 

which the end user may be entitled as a result of the sales transaction):

In the event of a justified and properly established claim, 

PEHA

 shall exercise its 

prerogative to either repair or replace the defective device. Further claims or liability 

for consequential damage are explicitly excluded. A justifiable deficiency is deemed to 

exist if the device exhibits a structural, manufacturing, or material defect that makes it 

unusable or substantially impairs its utility at the time it is turned over to the end user. 

The warranty does not apply to natural wear, improper usage, incorrect connection, 

device tampering or the effects of external influences. The warranty period is 24 months 

from the date of purchase by the end user from a dealer and ends not later than 36 

months after the device’s date of manufacture. German law shall be applicable for the 

settlement of warranty claims.

DIsPosAL oF The DeVIce

Do not dispose of old devices in the household waste! The device must be 

disposed of in compliance with the laws and standards of the country in which it 

is operated! The device contains electrical components that must be disposed 

of as electronics waste. The enclosure is made from recyclable plastic.

DescrIPTIon

The in-wall input module is designed for the decentralised application of the PHC 

system. The PHC bus is extended for that from the distributor to the installation site 

of the in-wall module.

The in-wall module without frame features eight external inputs (

I

0-

I

7

). PHC in-wall 

button modules (941 UP o.A.) can be connected for feedback at all inputs and PEHA 

buttons (550 LED/PHC) can be connected at the (

I

4-

I

7

) inputs. The LEDs of these 

buttons can be switched ON and OFF by the PHC system without additional wiring. 

The maximum allowed line length between buttons and the in-wall module is 25 

metres for the 24 Volt inputs and 5 meters for the 5 Volt inputs of the in-wall module. 

No more than one switch may be connected to the 

I

0 input. It is also possible to connect 

one switch to the 

I

0 input and a motion detector at the 

I

3 input. Otherwise only buttons 

are permitted! A feedback with switches is not possible.

connecTIon DIAgrAM

1 2 3 4 5

I

0

I

1

I

2

I

3

0V

I

6

I

7

I

5

I

4

+24V

+ A

-B

0 V

U

S

P

H

C

-B

ON

DIP

940/24 EM RÜ o.T.

LED

Phc bus

coding switch

connection of the external 

24 V inputs

connection of the external 

5 V inputs (LeD)

MounTIng

The installation of the PHC modules may be carried out by authorised technicians 

only. During installation the system‘s electricity has to be switched off. The PHC in-wall 

module without frame is designed for installation in a 60 mm in-wall box. If installing 

the in-wall module into a deep 60 mm in-wall box it is even possible to install the 

in-wall module behind a button.

Attention!!

 The PHC modules may 

not

 be employed in connection with devices that 

may endanger people, animals or property when operated.

The following points must be observed:

-  the valid laws, standards and regulations

-  the technical state of the art during installation

-  the PHC manual and the operating instructions of the PHC modules.

-  Operating instructions can only cite general stipulations. 

  These are to be viewed in the context of a specific system.

The following systems may not be switched by Phc output modules:

-  safety switches such as EMERGENCY OFF

-  emergency power supplies

-  fire alarm systems

-  emergency lighting systems

DATA connecTIon

The PHC in-wall module without frame requires the PHC BUS that serves as data 

connection and as voltage supply. The connection from the in-wall module to the 

control unit and to other modules is usually made by a JY(ST)Y line of 2x 2x 0.8 mm 

Ø and may have a length of no more than 1000 metres. When connecting the BUS 

line be sure that the lines A and B are not crossed. 

The PHC module can be positioned anywhere in the data line. Power needs to be 

switched off before disconnecting the bus line.

coDIng sWITch

The input module‘s address is set by the coding switch built into the PHC control 

module. The setting of the coding switch is presented in the PHC software under 

the menu item „

Components 

g

 Edit Modules

“. Make sure that no identical module 

addresses are given for PHC input modules. The setting of the coding switch may 

be carried out by technicians only. For this the PHC module needs to be switched off 

and it must be ensured that there can be no electrical discharge.

currenT consuMPTIon

The current consumption of the input module depends on the type and number of the 

connected command devices:

Own consumption: ............................................................................................15 mA

Input 

(

I

0-

I

2)

: .....................................................................................10 mA  per input

Input 

(

I

3-

I

7)

: .....................................................................................25 mA  per input

InsTALLATIon AnD oPerATIng InsTrucTIons
Phc in-wall input module without frame

for 24V Dc inputs and 5V Dc inputs with feedback

940/24 eM rÜ o.T.