Rev. 1
OWA 100 Adapter User Manual
39
September 2010
Hazardous Location
Certifications
CSA IS – ENTITY
- Cl I, Div. 1, Gp ABCDEFG; T4 (–40°C
≤
Ta
≤
+85°C); DIP Cl II, Div.
1, Gp EFG, CL III, Div. 1; T4 (–40°C
≤
Ta
≤
+85°C); Type 4X; IS – ENTITY - Cl I, Zone 0;
Ex ia IIC, T4 (–40°C
≤
Ta
≤
+85°C); IP66
CSA NI
- Cl I, Div. 2, Gp ABCD; T4 (–40°C
≤
Ta
≤
+85°C); DIP A22, Cl II, Div. 2, Gp FG;
CL III, Div. 2; T4 (–40°C
≤
Ta
≤
+85°C); Type 4X; NI - Cl I, Zone 2; Ex nA IIC, T4 (–40°C
≤
Ta
≤
+85°C); Type 4X
FM Approvals IS – ENTITY
- Cl I, Div. 1, Gp ABCDEFG; T4 (–40°C
≤
Ta
≤
+85°C); DIP
Cl II, Div. 1, Gp EFG, CL III, Div. 1; T4 (–40°C
≤
Ta
≤
+85°C); Type 4X; IS – ENTITY - Cl
I, Zone 0/1; AEx ia IIC; T4 (–40°C
≤
Ta
≤
+85°C); Zone 20/21; Ex ta IIIC T90°C T500
95°C , IP66
FM Approvals NI
- Cl I, Div. 2, Gp ABCD; T4 (–40°C
≤
Ta
≤
+85°C); DIP Cl II, Div. 2, Gp
FG; CL III, Div. 2; T4 (–40°C
≤
Ta
≤
+85°C); Type 4X; NI - Zone 2; AEx nA IIC, T4 (–40°C
≤
Ta
≤
+85°C); Zone 22, AEx tc IIIC T90°C , IP66
FM-IECEx IS – ENTITY
- Zone 0; Ex ia IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gb; Zone 20; Ex ta
IIIC T90°C T
500
95°C, Da, IP66;
FM-IECEx NS
- Zone 2; Ex nA IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gc; Zone 22, Ex tc IIIC
T90°C, Dc, IP66
FM-ATEX IS – ENTITY
- Zone 0;
Ex ia IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gb; Zone
20; Ex ta IIIC T90°C T
500
95°C, Da, IP66
FM-ATEX NS
- Zone 2;
Ex nA IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gc; Zone 22, Ex tc
IIIC T90°C, Dc, IP66
SAEx IS – ENTITY
- Zone 0; Ex ia IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gb; Zone 20; Ex ta IIIC
T90°C T
500
95°C, Da, IP66
SAEx NS
- Zone 2; Ex nA IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gc; Zone 22, Ex tc IIIC T90°C,
Dc, IP66
INMETRO IS – ENTITY
- Zone 0; BR-Ex ia IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gb; Zone 20;
BR-Ex ta IIIC T90°C T
500
95°C, Da, IP66
INMETRO NS
- Zone 2; BR-Ex nA IIC, T4 (–40°C
≤
Ta
≤
+70°C), Gc; Zone 22, BR-Ex tc
IIIC T90°C, Dc, IP66
* Actual range can vary depending on site topography.
Physical Specifications
Parameter
Description
Mounting
½” NPT or M20 Stainless Steel fitting that allows the adapter to be attached directly to the
conduit entry of any 2 or 4-wire HART device (standard options). Mounting should result
in the antenna being vertically oriented. An optional Remote Mounting Kit is available.
Housing
Molded Lexan Polycarbonate
V0 Rating and UV Stable.
Meets NEMA 4X (hosedown and corrosion resistant), IP 66 (dust/tight/hosedown).
Dimensions
See
Error! Reference source not found.
Net Weight
Approximately 1.0lb/(0.45Kg)
Содержание OWA 100 OneWireless
Страница 1: ...OneWireless OWA 100 OneWireless Adapter User Manual 34 XY 25 40 Revision 1 September 2010 ...
Страница 29: ...3 Configuration 3 4 Configuration 18 OWA 100 Adapter User Manual Rev 1 September 2010 ...
Страница 44: ...Rev 1 OWA 100 Adapter User Manual 33 September 2010 ...
Страница 45: ...34 OWA 100 Adapter User Manual Rev 1 September 2010 ...
Страница 46: ...Rev 1 OWA 100 Adapter User Manual 35 September 2010 ...
Страница 47: ...36 OWA 100 Adapter User Manual Rev 1 September 2010 ...
Страница 48: ...Rev 1 OWA 100 Adapter User Manual 37 September 2010 ...