background image

51268E-01 

Note:  

In case of battery replacement, this must be replaced with parts of the same type and characteristics. 

The replacement must be performed by the manufacturer or a competent person. 

 
Note:  

The light source is non-replaceable. 

 

Note:  

If the supply cable of the luminaire is damaged, it shall exclusively be replaced by a competent person 

in order to avoid hazard. 

 

Battery replacement:

 

Disconnect mains, carefully pull the luminaire and main unit down, make 
sure that the springs do not snap. Unscrew the battery cover (step 3, 
screw 

A

). Disconnect the battery and install a new one of the same type 

and characteristics. Refit the cover and fasten the screw. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
The 

Ova/OmniLED R Spot

 is a self-contained non-maintained luminaire with selftest function. 

 

Selftest functions 

Every 15 days the luminaire will perform an emergency operation test, this will light the white LED for 
approx. 3 seconds. The red LED will flash during this test sequence. 
 
Every 6. month the luminaire will perform a battery condition test. The test will last for 60 minutes. The 
white LED will be lit and the yellow LED will flash during this test sequence. 
 

Note:

 When using DALI or Wireless communication, the frequencies and schedules for tests will 

instead be determined by the connected PC software. 
 

Manual test functions 

Manual tests can only be performed if both mains and battery are connected. 
 
By pressing the test button briefly (less than 5 seconds) an emergency operation test is performed. 
The white LED will be lit for approx. 3 seconds, the red LED will flash during this test sequence. 
 
By pressing the test button for between 5 and 10 seconds a battery condition test is performed. 
This test will last for 60 minutes and can only be performed when the battery is fully charged (steady 
green LED). The white LED will be lit and the yellow LED will flash during this test sequence. 
 

Resetting errors 

Push the test button for >10 seconds to delete all indicated errors. Then the luminaire enters regular 
operation mode. 
 
In case that the luminaire no longer meets its rated duration of operation, the battery must be replaced 
(see chapter “Battery replacement” on top of this page). 
 
 
 
 
 
 
 
 

Part number: 

 

290071.10 

Lumen output: 

 

350 lm 

Operation voltage:  

 

220-240VAC 50/60Hz 

Emergency mode duration: 

Minimum 1 hour 

Battery: 

 

 

6,4V / 1,2Ah LiFePO4 

Battery protection: 

 

Overcharge and full discharge 

Charging time:  

 

18 hours 

Maximum power consumption:  

3,8W / 4,3VA 

Ambient temperature range:  

5 to 40°C 

Relative humidity: 

 

Up to 95% 

Weight: 

 

 

440 g 

Classification: 

 

EN 60598-2-22 

Technical lifetime (light source): 

> 100000 hours 

IP20 
Expected battery lifetime 10 years 

Technical description 

GB 

Indicator LEDs 

G

R

EE

N

 

 

YE

LL

O

W

 

 

R

ED

 

 

Normal 

Charging (battery test not possible while charging) 

Mains off, battery not connected or charger fault 

Battery test 

Battery fault 

Light source test 

Light source fault 

Battery fault and light source fault 

 

Description 

LED status explanation 

Off 

 

On 

 

Flashing 

 

Important notice when installing 
luminaires within the same area!!! 

To avoid that luminaires perform their 
battery test at the same day, connect 
the battery packs with more than 1,5 

minutes inbetween. 

 

At the end of their useful life the 
packaging, product and batteries 
should be disposed of via a 
suitable recycling centre. Do not 
dispose of with your normal 
household waste. Do not burn. 

Содержание Ova/OmniLED R

Страница 1: ...ver and fasten the removed screw A in step 3 Step 5 Connect the mains cables to the terminal blocks L for live wire N for neutral The ground terminal is optional The C1 and C2 terminals are used for elBus communication optional DALI communication optional or voltage free contact optional After the connection of the cables secure them with the provided ties Refit the cover B and fasten the removed ...

Страница 2: ...test sequence By pressing the test button for between 5 and 10 seconds a battery condition test is performed This test will last for 60 minutes and can only be performed when the battery is fully charged steady green LED The white LED will be lit and the yellow LED will flash during this test sequence Resetting errors Push the test button for 10 seconds to delete all indicated errors Then the lumi...

Страница 3: ... i elektronikkenheten Monter batteridekslet og skru fast skruen A i pkt 3 Pkt 5 Koble nettkabel L N jord er valgfri til rekkeklemmen C1 og C2 benyttes til elBus kommunikasjon tilleggsutstyr DALI kommunikasjon tilleggsutstyr eller potensialfri kontakt tilleggsutstyr Etter at kablene er koblet kan de sikres med de medfølgende kabelstripsene Monter dekslet og skru fast skruen B i pkt 3 Plasser elektr...

Страница 4: ...ker i denne perioden Ved å trykke inn testknappen i en lengre periode mellom 5 og 10 sekunder utføres en test av batteriets kapasitet Denne testen varer 60 minutter og kan kun startes når batteriet er fullt oppladet grønn LED lyser fast Armaturen vil lyse i denne perioden og gul LED blinke Tilbakestilling av feil Hold testknappen inne i mer enn 10 sekunder for å slette eventuelle feilindikasjoner ...

Страница 5: ...enheten Montera batterikåpan och skruva fast skruv A från steg 3 Steg 5 Anslut spänningskabeln till kopplingsplinten L för fas N för noll jord är valfri C1 och C2 används för elBus kommunikation tillval DALI kommunikation tillval eller pot fri larmutgång tillval Efter inkoppling avlastas kablaget med det medföljande buntbandet Montera elektronikkåpan och skruva fast skruv B från steg 3 Placera ele...

Страница 6: ...estperioden Genom att trycka in testknappen mellan 5 till 10 sekunder startas ett test av batterikapaciteten Testet pågår under 60 minuter och kan endast startas när batteriet är fullt uppladdat grön diod lyser konstant Armaturens LED lampa tänds upp och den gula indikeringsdioden blinkar under test perioden Återställning av fel Håll in testknappen i mer än 10 sekunder för att återställa eventuell...

Отзывы: