Configuring via the Web Server
Configuring the System
NetAXS™ Access Control Unit User’s Guide
,
Document 800-00233, Revision A
2
-
11
2.2.5 Downstream Devices Tab
The NetAXS™ downstream devices are Monitorable Input Relay Output (MIRO)
boards. These boards provide the NetAXS™ panel with additional inputs and outputs.
The NetAXS™ panel supports two MIRO types:
•
32/0 – Provides 32 inputs and no outputs. The 32/0 MIRO boards must be
assigned network addresses 1 and 2.
•
2/16 – Provides two inputs and 16 outputs. The 2/16 MIRO boards must be
assigned network addresses 3-6.
Note:
The MIRO network addresses are set by the DIP switches on each board. Refer
to the “Downstream I/O” section in the
NetAXS™ Access Control Unit NX4L1
Installation Guide
or the
NetAXS™ Access Control Unit NX4S1 Installation Guide
for
more information about setting MIRO DIP switches.
A NetAXS™ panel supports a maximum of six daisy-chained MIROs – two 32/0
boards and four 2/16 boards. The boards connect to the NetAXS™ panel’s
Downstream port (Terminal Block 10).
Click the
Downstream Devices
tab:
Figure 2-5: Configuration > System > Downstream Devices Tab
Содержание NetAXS
Страница 8: ...viii www honeywell com ...
Страница 18: ...1 10 www honeywell com Connecting to the Web Server Reading the Select Panel ...
Страница 74: ...2 56 www honeywell com Configuring via the Web Server Configuring Users ...
Страница 84: ...3 10 www honeywell com Configuring via WIN PAK Adding a New NetAXS Panel ...
Страница 86: ...3 12 www honeywell com Configuring via WIN PAK Adding a New NetAXS Panel ...
Страница 100: ...4 14 www honeywell com Monitoring NetAXS Status Monitoring System Status ...