background image

7 - 2

Step 1 - Take a Picture Using IMGSNP

Image Snap - IMGSNP

An image is taken whenever the hardware button is pressed, or when the Image 
Snap (IMGSNP) command is processed.    

The image snap command has many different modifiers that can be used to 
change the look of the image in memory.  Modifiers always begin with numbers 
and end with a letter (case insensitive).  Any number of modifiers may be 
appended to the IMGSNP command.  For example, you can use the following 
command to snap an image, increase the gain, and have the beeper sound 
once the snap is complete:  

IMGSNP2G1B

IMGSNP Modifiers

P - Imaging Style

  

This sets the Image Snap style.  

0P

Decoding Style

.  This processing allows a few frames to be taken 

until the exposure parameters are met.  The last frame is then 
available for further use.

1P

Photo Style 

(default)

.  This mimics a simple digital camera, and 

results in a visually optimized image.

2P

Manual Style

.  This is an advanced style that should only be used 

by an experienced user.  It allows you the most freedom to set up 
the engine, and has no auto-exposure.

B - Beeper

Causes a beep to sound after an image is snapped.

0B No beep 

(default)

1B Sounds a beep when the image is captured. 

T - Wait for Trigger

Waits for a hardware button push before taking the image.  This is only 
available when using Photo Style (1P).

0T Takes image immediately 

(default)

1T Waits for a button push, then takes the image

L - LED State

Determines if the LEDs should be on or off, and when.  Ambient illumina-
tion (0L) is preferred for taking pictures of color documents, such as ID 
cards, especially when the scanner is in a stand.  LED illumination (1L) is 
preferred when the device is handheld.  LED State is not available when 
using Decoding Style (0P).  

0L LEDs off 

(default)

1L LEDs on 

Содержание N86 Series

Страница 1: ... N86XX Decoded Engine User s Guide http manualforhoneywellthermostat com ...

Страница 2: ...ht All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of HII 2012 Honeywell International Inc All rights reserved Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners Web Address www honey...

Страница 3: ...ies please contact Honeywell Imaging Mobility Europe BV Nijverheidsweg 9 13 5627 BT Eindhoven The Netherlands CB Scheme IEC 60950 1 Second Edition UL C UL Recognized component UL 60950 1 Second Edition CSA C22 2 No 60950 1 07 2nd Edition LED Safety Statement LEDs have been tested and classified as EXEMPT RISK GROUP to the standard IEC 62471 2006 ESD Precautions The engine is shipped in ESD safe pa...

Страница 4: ...aging Dust and other external contaminants will eventually degrade unit performance RoHS The engine is in compliance with Directive 2002 95 EC Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment RoHS dated January 2003 D Mark Statement Certified to EN 60950 1 Information Technology Equipment product safety as a component assembly ...

Страница 5: ... Chapter 2 Programming the Interface Introduction 2 1 Programming the Interface Plug and Play 2 1 RS232 Serial Port 2 1 USB PC 2 1 USB COM Port Emulation 2 1 Verifone Ruby Terminal Default Settings 2 2 Gilbarco Terminal Default Settings 2 3 Keyboard Country Layout 2 4 Keyboard Style 2 10 Keyboard Conversion 2 12 Control Character Output 2 12 Keyboard Modifiers 2 13 RS232 Baud Rate 2 15 RS232 Word ...

Страница 6: ...od Read Delay 3 6 Manual Trigger Modes 3 6 Serial Trigger Mode 3 7 Read Time Out 3 7 Image Snap and Ship 3 8 Reread Delay 3 8 User Specified Reread Delay 3 9 Illumination Lights 3 9 Centering 3 9 Preferred Symbology 3 11 High Priority Symbology 3 11 Low Priority Symbology 3 12 Preferred Symbology Time out 3 12 Preferred Symbology Default 3 12 Output Sequence Overview 3 13 Require Output Sequence 3...

Страница 7: ...er Interfunction and Intermessage Delays 4 4 Intercharacter Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage Delay 4 6 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 To Add a Data Format 5 1 Other Programming Selections 5 3 Terminal ID Table 5 4 Data Format Editor Commands 5 4 Move Commands 5 5 Search Commands 5 6 Miscellaneous Commands 5 7 Data...

Страница 8: ...aight 2 of 5 Industrial three bar start stop 6 15 Straight 2 of 5 IATA two bar start stop 6 16 Matrix 2 of 5 6 17 Code 11 6 18 Code 128 6 19 ISBT 128 Concatenation 6 19 Code 128 Code Page 6 21 GS1 128 6 22 Telepen 6 23 UPC A 6 24 UPC A EAN 13 with Extended Coupon Code 6 26 UPC E0 6 27 UPC E1 6 30 EAN JAN 13 6 30 ISBN Translate 6 32 EAN JAN 8 6 33 MSI 6 35 GS1 DataBar Omnidirectional 6 37 GS1 DataB...

Страница 9: ...tal Codes 2D 6 52 Single 2D Postal Codes 6 52 Combination 2D Postal Codes 6 53 Postal Codes Linear 6 55 China Post Hong Kong 2 of 5 6 55 Korea Post 6 57 Chapter 7 Imaging Commands Single Use Basis 7 1 Command Syntax 7 1 Image Snap IMGSNP 7 2 IMGSNP Modifiers 7 2 Image Ship IMGSHP 7 5 IMGSHP Modifiers 7 5 Intelligent Signature Capture IMGBOX 7 14 Signature Capture Optimize 7 14 IMGBOX Modifiers 7 1...

Страница 10: ...from the Web 9 4 Chapter 10 Serial Programming Commands Conventions 10 1 Menu Command Syntax 10 1 Query Commands 10 2 Responses 10 2 Trigger Commands 10 4 Resetting the Custom Defaults 10 4 Menu Commands 10 5 Chapter 11 Maintenance Repairs 11 1 Inspecting Cords and Connectors 11 1 Troubleshooting 11 1 Chapter 12 Customer Support Technical Assistance 12 1 Appendix A Reference Charts Symbology Chart...

Страница 11: ...8690 8693 unit includes the OCR feature For software updates and additional information visit the Honeywell website at www honeywellaidc com About This Manual This User s Guide provides demonstration installation and programming instructions for the N86XX engine Dimensions warranty and customer sup port information are also included Honeywell s bar code scanners are factory programmed for the most...

Страница 12: ...od els that can be used with your interface Models Interface Decoding Capability N868XX XXX XX2 TTL Level 232 Linear 2D postal N868XX XXX XX3 Full Speed USB Linear 2D postal N868XX XXX XX5 High Speed USB Linear 2D postal N869XX XXX XX2 TTL Level 232 Linear 2D postal OCR N869XX XXX XX3 Full Speed USB Linear 2D postal OCR N869XX XXX XX5 High Speed USB Linear 2D postal OCR ...

Страница 13: ...r through the flex connector Doing so may damage the host or engine The N86XXX XXX XX5 engine will only communicate USB through the Micro B connector The N86XXX XXX XX3 engine will only communicate USB through the 10 pin modular connector 1 Turn off power to the terminal computer 2 If using full speed USB connect the USB interface cable to the interface board and to the matching USB port on the co...

Страница 14: ... honeywellaidc com 3 When connecting the engine using full speed or high speed USB all communication parameters between the engine and terminal must match for correct data transfer using USB protocol Scan the appropriate USB interface bar code below 4 Verify the engine operation by scanning a bar code from the Sample Symbols in the back of this manual The engine beeps once when a bar code is succe...

Страница 15: ...he power supply 3 Turn the terminal computer power back on The engine beeps 4 If connecting the engine using an RS 232 interface all communication parameters between the engine and terminal must match for correct data transfer through the serial port using RS 232 protocol Scan the RS 232 interface bar code below This programs the engine for an RS 232 interface at 115 200 baud parity none 8 data bi...

Страница 16: ...ires scanning numeric codes from the back cover then a Save code that entire sequence will be saved to your custom defaults When you have entered all the commands you want to save for your custom defaults scan the Save Custom Defaults bar code You may have a series of custom settings and want to correct a single setting To do so just scan the new setting to overwrite the old one For example if you...

Страница 17: ...and want to restore the engine to factory default set tings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the engine to the factory default settings The Menu Commands beginning on page 10 5 list the factory default settings for each of the commands indicated by an asterisk on the programming pages This selection erases all your settings and resets the engin...

Страница 18: ...1 8 ...

Страница 19: ...rminal The following RS232 Interface bar code also pro grams a carriage return CR and a line feed LF suffix baud rate and data format as indicated below It also changes the trigger mode to man ual USB PC Scan the following code to program the engine for USB PC Keyboard Scanning this code also adds a CR and LF USB COM Port Emulation Scan the following code to program the engine to emulate a regular...

Страница 20: ...e Verifone Ruby Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Veri fone Ruby terminal This bar code sets the baud rate to 1200 bps and the data format to 8 data bits no parity bit 1 stop bit It also adds a line feed LF suffix and programs the following prefixes for each symbology Symbology Prefix UPC A A UPC E A EAN 8 FF EAN 13 F USB COM Port Emulatio...

Страница 21: ...l barco terminal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also adds a carriage return CR suffix and programs the following prefixes for each symbology Symbology Prefix UPC A A UPC E E0 EAN 8 FF EAN 13 F Verifone Ruby Settings Gilbarco Settings ...

Страница 22: ... or language As a general rule the following characters are sup ported but need special care for countries other than the United States United States United States Dvorak left United States International Albania Azeri Cyrillic Azeri Latin Belarus Belgium United States Dvorak United States Dvorak right Bosnia Brazil ...

Страница 23: ...eyboard Country continued Bulgaria Latin Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Bulgaria Cyrillic Canada French legacy Brazil MS Denmark Dutch Netherlands ...

Страница 24: ...2 6 Keyboard Country continued Finland Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Faeroese France Estonia Greek Latin Greek MS ...

Страница 25: ...2 7 Keyboard Country continued Italian 142 Hungarian 101 key Iceland Irish Italy Japan ASCII Kazakh Kyrgyz Cyrillic Hebrew Hungary Greek Polytonic Latin America Latvia ...

Страница 26: ...2 8 Keyboard Country continued Lithuania IBM Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Lithuania Macedonia Latvia QWERTY Romania Russia ...

Страница 27: ...2 9 Keyboard Country continued SCS Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Russian Typewriter Serbia Cyrillic Russian MS Sweden Switzerland French ...

Страница 28: ...If you have used Keyboard Conversion settings they will override any of the following Key board Style settings Default Regular Turkey F Ukrainian United Kingdom United Stated Dvorak right United States Dvorak left United States Dvorak United States International Uzbek Cyrillic Tatar Turkey Q Switzerland German ...

Страница 29: ...e tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock sta tus AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Ger many France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Autocaps but uses the Num Lock key to retrieve t...

Страница 30: ... Keyboard Style selections Note If your interface is a keyboard wedge first scan the menu code for Automatic Caps Lock page 2 11 Otherwise your output may not be as expected Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR in...

Страница 31: ...s not support all keyboard country codes New users should use the Windows mode Refer to Keyboard Function Relationships page 8 1 for CTRL ASCII Values Windows Mode Prefix Suffix Off The engine sends key combinations for ASCII control characters for values 00 1F but it does not transmit any prefix or suffix information Default Control ASCII Mode Off Control Character Output On Control Character Out...

Страница 32: ...ds numeric characters as if entered from a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Страница 33: ...Rate Baud Rate sends the data from the engine to the terminal at the specified rate The host terminal must be set for the same baud rate as the engine Default 9600 300 2400 600 1200 4800 38400 9600 19200 115 200 57 600 ...

Страница 34: ...cations that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Data 1 Stop Parity None 8 Data 1 Stop Parity ...

Страница 35: ...s control of data transmission from the engine using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The engine asserts RTS when it has data to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The engine asserts RTS when it is OK for the host to transmit The host asserts CTS when it ...

Страница 36: ...ta XON XOFF On or to stop sending data XON XOFF Off When the host sends the XOFF character DC3 hex 13 to the engine data transmission stops To resume transmission the host sends the XON character DC1 hex 11 Data transmission continues where it left off when XOFF was sent Default XON XOFF Off ACK NAK After transmitting data the engine waits for an ACK character hex 06 or a NAK character hex 15 resp...

Страница 37: ...2 19 the engine waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off ACK NAK On ACK NAK Off ...

Страница 38: ...2 20 ...

Страница 39: ...Off bar code s if you don t want a power up beep Default Power Up Beeper On Scanner Beep on BEL Character You may wish to force the engine to beep upon a command sent from the host If you scan the Beep on BEL On bar code below the engine will beep every time a BEL character is received from the host Default Beep on BEL Off Power Up Beeper Off Scanner Power Up Beeper On Scanner Beep on BEL Off Beep...

Страница 40: ...fect on serial or automatic triggering Default Trigger Click Off Good Read and Error Indicators Beeper Good Read The beeper may be programmed On or Off in response to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Trigger Click On Trigger Click Off Beeper Good Read On Beeper Goo...

Страница 41: ... the volume of the beep the engine emits on a good read Default High Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the engine emits on a good read Default Medium High Medium Off Low Low 1600 Hz Medium 2700 Hz High 4200 Hz ...

Страница 42: ...lt Razz Beeper Duration Good Read The beeper duration codes modify the length of the beep the engine emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep LED Good Read On LED Good Read Off ...

Страница 43: ...git 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the engine for a bad read or error can be programmed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the numb...

Страница 44: ...ds by scanning digits from the inside back cover then scanning Save Manual Trigger Modes When in manual trigger mode the scanner scans until a bar code is read or until the trigger is released Two modes are available Normal and Enhanced Normal mode offers good scan speed and the longest working ranges depth of field Enhanced mode will give you the highest possible scan speed but No Delay Short Del...

Страница 45: ...he scanner can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the trigger or using a serial trigger command After scanning the R...

Страница 46: ...l command for Manual Trigger Modes see page 10 13 in order to use menu codes after using Image Snap and Ship Reread Delay This sets the time period before the engine can read the same bar code a sec ond time Setting a reread delay protects against accidental rereads of the same bar code Longer delays are effective in minimizing accidental rereads Use shorter delays in applications where repetitive...

Страница 47: ... to turn just the lights off scan the Lights Off bar code Default Lights On Centering Use Centering to narrow the engine s field of view to make sure the engine reads only those bar codes intended by the user For instance if multiple codes are placed closely together centering will insure that only the desired codes are read In the example below the gray area is the full engine field of view and t...

Страница 48: ...tering On the engine only reads codes that intersect the centering window you specify using the Top Bottom Left or Right bar codes Scan Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 fo...

Страница 49: ...ferred Symbology Time out on page 3 12 while it searches for the high priority symbology If a high priority symbology is located during this period then that data is read immediately If the time out period expires before a high priority symbology is read the engine will read any bar code in its view low priority or unspecified If there is no bar code in the engine s view after the time out period ...

Страница 50: ...iority symbologies Scan Save to save your selection Default None Preferred Symbology Time out Once you have enabled Preferred Symbology and entered the high and low priority symbologies you must set the time out period This is the period of time the engine will search for a high priority bar code after a low priority bar code has been encountered Scan the bar code below then set the delay from 1 3...

Страница 51: ... code length and character match es your application requires Use the Alphanumeric symbols inside back cover to read these options To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output Sequence page 3 16 2 Code I D On the Symbology Chart on page A 1 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbology and scan the ...

Страница 52: ...nce editor with the following command line SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 code length that must mat...

Страница 53: ...A Code 39 sample length 11 plus CR suffix 1 12 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93 sample length 11 plus CR suffix 1 12 43 start character matc...

Страница 54: ... the engine will attempt to get the out put data to conform to an edited sequence but if it cannot the engine transmits all output data to the host device as is When the output sequence is Off the bar code data is output to the host as the engine decodes it Default Off Note This selection is unavailable when the Multiple Symbols Selection is turned on Multiple Symbols When this programming selecti...

Страница 55: ...o Read With No Read turned On the engine notifies you if a code cannot be read If using an EZConfig Tool Scan Data Window see page 9 3 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 5 1 The hex code for th...

Страница 56: ...r codes Scan Video Reverse and Standard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setting for decoding only Video Reverse Only Video Reverse Off VIDREV0 Video Reverse ...

Страница 57: ...ault suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 beginning on page A 4 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output When setti...

Страница 58: ...thout saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for U P C only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the Symbology Chart beginning on page A 1 for U P C Step 3 Scan 6 3 from the Programming Chart inside the back cover of this ma...

Страница 59: ...e from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then pro grams a carriage return suffix for all symbologies Prefix Sele...

Страница 60: ...ce Keys starting on page 8 2 When the engine is in keyboard wedge mode the scan code is con verted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Add Suff...

Страница 61: ...ercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit hex valu...

Страница 62: ...side the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this man ual To remove this delay scan the Intermessage Delay bar code then set t...

Страница 63: ...3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID Universal Length 7 Universal Terminal ID Universal Code ID Actual Length 8 Universal Terminal ID Universal Code ID Universal Length The maximum size of a data format configuration is 2000 bytes w...

Страница 64: ... the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Step 5 Length Specify what length up to 9999 characters of data will be acceptable for this symbology Scan the four digit data length from the Programming Chart inside the back cover of this manual Note 50 characters is entered as 0050 9999 is a universal number indicati...

Страница 65: ...r of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Chart on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes ...

Страница 66: ...es Send a number of characters F2 Include in the output message a number of characters followed by an insert character Start from the current cursor position and continue for nn characters or through the last character in the input message followed by character xx Syntax F2nnxx where nn stands for the numeric value 00 99 for the number of characters and xx stands for the insert character s hex val...

Страница 67: ...the cursor in the current position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 99 for the number of times it should be sent Refer to the ASCII Conversion Chart Code Page 1252 page A 4 for decimal hex and character codes Insert symbology name B3 Insert the name of the bar code s symbology in the output message without moving t...

Страница 68: ... Refer to the ASCII Conversion Chart Code Page 1252 page A 4 for decimal hex and character codes Search forward for a string B0 Search forward for s string from the current cursor position leaving cursor pointing to s string Syntax B0nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of each character in the match string For example B0000454657374 will search fo...

Страница 69: ...ers FB Suppress all occurrences of up to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is encountered the suppress function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list and xxyy zz is the list of characters to be supp...

Страница 70: ...codes Check for a number EC Check to make sure there is an ASCII number at the current cursor position The format is aborted if the character is not numeric Check for non numeric character ED Check to make sure there is a non numeric ASCII character at the current cursor position The format is aborted if the character is not numeric Insert a delay EF Inserts a delay of up to 49 995 milliseconds in...

Страница 71: ...cular symbol those prefixes and suffixes are not transmitted Any data that does not match your data format requirements generates an error tone If you wish to process this type of bar code without generating an error tone see Data Format Non Match Error Tone Choose one of the following options Default Data Formatter On Not Required Keep Prefix Suffix Data Format Non Match Error Tone When a bar cod...

Страница 72: ...s saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Single Scan Data Format Change You can also switch between data formats for a single scan The next bar code is scanned using an alternate data format then reverts to the format you have selected above either Primary 1 2 or 3 Data Format Non Match Error T...

Страница 73: ...witch to Data Format 1 for a single trigger pull by scanning the Single Scan Data Format 1 bar code below The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Single Scan Data Format 1 Single Scan Data Format 2 Single Scan Data Format 3 Single Scan Primary Data Format ...

Страница 74: ...5 12 ...

Страница 75: ... Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 128 Postal Codes Linear Code 32 Pharmaceutical PARAF PDF417 Code 39 GS1 DataBar Omnidirectional Code 93 QR Code Data Matrix Straight 2 of 5 IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 8 TCIF Linked Code 39 TLC39 GS1 Composite Codes Telepen GS1 DataBar Expanded Trioptic Code GS1 DataBar Limited UPC A...

Страница 76: ... engine will issue an error tone You may wish to set the same value for minimum and maximum length to force the engine to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value oth...

Страница 77: ...ters are created using different modulos You can program the engine to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the engine reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the engine will only read Codabar bar codes printed with a check character a...

Страница 78: ...gine looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two mes sages are concatenated into one with the D characters omitted Select Require to prevent the engine from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Character Validate ...

Страница 79: ...e bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Страница 80: ...Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the engine reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Tran...

Страница 81: ...mation Mini mum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the engine to append the data from several Code 39 bar codes together before transmitting them to the host computer When this function is enabled the engine stores those Code 39 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the...

Страница 82: ...39 bar code that starts with a character other than a space Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital ian pharmacies This symbology is also known as PARAF Note Trioptic Code page 6 39 must be turned off while scanning Code 32 Pharmaceutical codes Off On Off On ...

Страница 83: ...s created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D ...

Страница 84: ...t All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off Check Digit No Check Digit indicates that the engine reads and transmits bar code data with or without a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data Code 39 Code Page On Off ...

Страница 85: ...e scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Validate but Don t Transmit No Check Digit Validate and Transmit Minimum Message Length Maximum Message Length ...

Страница 86: ...but Don t Transmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the engine only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit On Off No Check Digit Validate and Transmit Validat...

Страница 87: ...the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Страница 88: ... Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping ...

Страница 89: ... start stop Default All Straight 2 of 5 Industrial Settings Straight 2 of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Code 93 Code Page On Off Minimum Message Length Maximum Message Len...

Страница 90: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Off On Minimum Message Length Maximum Message Length ...

Страница 91: ...atrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Maximum Message Length Minimum Message Length ...

Страница 92: ...1 Default All Code 11 Settings Code 11 On Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits On Off One Check Digit Two Check Digits ...

Страница 93: ...enation In 1994 the International Society of Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood prod ucts 2 the current recommendation to use Code 128 due to its high degree of security and its spac...

Страница 94: ...Append This function allows the engine to append the data from several Code 128 bar codes together before transmitting them to the host computer When this function is enabled the engine stores those Code 128 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The engine stores the data in the order in which the bar codes are read deleti...

Страница 95: ...ing a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Code ...

Страница 96: ... Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Страница 97: ...t stop pat tern 1 and decodes them as standard full ASCII start stop pattern 1 When Original Telepen Output is selected the engine reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output On Off Original Telepen Output AIM Telepen Output ...

Страница 98: ...al information Mini mum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A On Off UPC A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On Minimum Message Length Maximum Message Length On Off On Off ...

Страница 99: ...s selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Required is scanned the engine will only read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 6 25 Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not ...

Страница 100: ...gine treats Coupon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the engine sees the coupon code and the extended coupon code in a single scan it transmits both as sepa rate symbologies Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the engine must see and read the coupon code and extended coupon ...

Страница 101: ...th the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 6 30 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 On UPC E0 Off On Off ...

Страница 102: ...0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Not Required Required Off On Off On ...

Страница 103: ...data but the unit can be programmed so it will not transmit it To prevent transmission scan Off Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Страница 104: ...es that lead with the 1 number system use the UPC E1 On selection Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 On Off EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E1 On UPC E1 Off On Off Off On ...

Страница 105: ...3 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the engine will only read EAN JAN 13 bar codes that have addenda Default Not Required 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Страница 106: ...om the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 6 26 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Off On Off On ...

Страница 107: ... Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Страница 108: ...red is scanned the engine will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Страница 109: ...rogram the engine to read MSI bar codes with Type 10 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 11 and Transmit the engine will only read MSI bar codes printed with the specified type check character s and will transmit the character s at the end of the scanned data On Off ...

Страница 110: ... length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit Validate Type 10 but Don t Transmit Validate 2 Type 10 Characters but Don t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 10 then Type 11 Character but Don t Transmit Validate Type 10 then Type 11 Ch...

Страница 111: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Страница 112: ...n Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 On Off Minimum Message Length Maximum Message Length ...

Страница 113: ... If you are going to scan Code 32 Pharmaceutical codes page 6 8 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media Codablock A Default All Codablock A Settings Codablock A On Off On Off On Off ...

Страница 114: ...the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 Minimum Message Length Maximum Message Length ...

Страница 115: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off Minimum Message Length Maximum Message Length ...

Страница 116: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Maximum Message Length Minimum Message Length ...

Страница 117: ...oPDF417 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 Off On Maximum Message Length Minimum Message Length ...

Страница 118: ...code GS1 Composite sym bols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component GS1 Composite Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2435 Minimum Default 1 Maximum Default 2435 On Off UPC...

Страница 119: ...ue will be the GS1 128 AIM ID C1 see Symbology Chart on page A 1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 DataBar AIM ID em see Symbology Chart on page A 1 If GS1 Code Expansion Off is scanned retail code expansion is disabled and UPC E expansion is controlled by the UPC E0 Expand pa...

Страница 120: ...ll bar code readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR Code Settings QR Code On Off This selection applies to both QR Code and Micro QR Code Off On On Off ...

Страница 121: ...s the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer When the scanner encounters an QR Code bar code with the append trigger character s it buffers the number of QR Code bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes...

Страница 122: ...ata Matrix Code Page Data Matrix Code pages define the mapping of character codes to charac ters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created...

Страница 123: ...ar properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Data Matrix Code Page On Off Maximum Message Length Minimum Message Length ...

Страница 124: ...ztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Pag...

Страница 125: ...se Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Aztec Code Page Off On Maximum Message Length Minimum Message Length ...

Страница 126: ...an be active at a time If you scan a second 2D postal code selection the first selection is over written Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On Japanese Post On KIX Post On Planet Code On British Post On Also see Planet Code Check Digit page 6 55 Canadian Post On Intelligent Mail Bar Code On Postal 4i On ...

Страница 127: ...6 55 Planet Code and Postnet On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Planet Code and Postnet with B and B Fields On Postal 4i and Postnet with B and B Fields On Intelligent Mail Bar Code and Postnet with B and B Fields On InfoMail and British Post On ...

Страница 128: ...Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postnet and Postal 4i On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code and Intelligent Mail Bar Code On Planet Code and P...

Страница 129: ... to specify whether the check digit should be transmitted at the end of Postnet data Default Don t Transmit Postal Codes Linear The following lists linear postal codes Any combination of linear postal code selections can be active at a time China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings Don t Transmit Check Digit Transmit Check Digit Don t Transmit Check Digit Transmi...

Страница 130: ... 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 80 On Off Minimum Message Length Maximum Message Length ...

Страница 131: ...tion page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Default Don t Transmit On Off Minimum Message Length Maximum Message Length Don t Transmit Check Digit Transmit Check Digit ...

Страница 132: ...6 58 ...

Страница 133: ...d such as setting the Imaging Style to 1P and the Wait for Trigger to 1T you would enter IMGSNP1P1T Note After processing an image capture command IMGSNP or IMGBOX you must follow it with an IMGSHP command if you want to see it on your terminal To add a command to a sequence each new command is separated with a semicolon For example to add the Image Ship command to the above sequence you would ent...

Страница 134: ...for further use 1P Photo Style default This mimics a simple digital camera and results in a visually optimized image 2P Manual Style This is an advanced style that should only be used by an experienced user It allows you the most freedom to set up the engine and has no auto exposure B Beeper Causes a beep to sound after an image is snapped 0B No beep default 1B Sounds a beep when the image is capt...

Страница 135: ...ure time can increase dramatically due to the near absence of light Units are 127 microseconds Default 7874 nE Range 1 7874 G Gain Gain is used in Manual Style only 2P Gain brightens images Your Exposure setting will affect your results when using Gain As you increase the gain the noise in an image is also amplified 1G No gain default 2G Medium gain 4G Heavy gain 8G Maximum gain Example of Exposur...

Страница 136: ...This sets the maximum number of frames the engine should take to reach the D Delta for Acceptance Update Tries is only available when using Photo Style 1P Default 6 nU Range 0 10 Target Set Point Percentage Sets the target point for the light and dark values in the captured image A setting of 75 means 75 of the pixels are at or below the target white value and 25 of the pixels are above the target...

Страница 137: ...always begin with a num ber and end with a letter case insensitive Any number of modifiers may be appended to the IMGSHP command For example you can use the following command to snap and ship a bitmap image with gamma correction and docu ment image filtering IMGSNP IMGSHP8F75K26U IMGSHP Modifiers A Infinity Filter Enhances pictures taken from very long distances greater than 10 feet or 3m The Infi...

Страница 138: ...led default 1C Compensation enabled D Pixel Depth Indicates the number of bits per pixel in the transmitted image KIM or BMP format only 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and white image 24D 24 bits per pixels for BMP format Example of Compensation at 0C Example of Compensation at 1C ...

Страница 139: ...or typical image ne Apply edge sharpen using strength n n 1 24 F File Format Indicates the desired format for the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed binary upper left to lower right 1 pixel bit 0 padded end of line 5F Uncompressed grayscale upper left to lower right bitmap format 6F JPEG image default 8F BMP format lower right to ...

Страница 140: ... Invert image is used to rotate the image around the X or Y axis 1ix Invert around the X axis flips picture upside down 1iy Invert around the Y axis flips picture left to right Example of Histogram Stretch at 0H Example of Histogram Stretch at 1H Example of image with Invert Image set to 1ix Example of image not inverted Example of image with Invert Image set to 1iy ...

Страница 141: ...e 0ir Image as snapped rightside up default 1ir Rotate image 90 degrees to the right 2ir Rotate image 180 degrees upside down 3ir Rotate image 90 degrees to the left Example of Noise Reduction On 1if Example of Noise Reduction Off 0if Example of Image Rotate set to 0ir Example of Image Rotate set to 2ir Example of Image Rotate set to 1ir Example of Image Rotate set to 3ir ...

Страница 142: ...ng for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 0 1 000 L R T B M Image Cropping Note Image Cropping should not be used with IMGSHP Modifiers see page 7 5 Ships a window of the image by specifying the left right top and bottom pixel coordinates Device columns are numbered 0 through 1279...

Страница 143: ... the protocol used to send the data Hmodem which is an Xmodem 1K variant that has additional header infor mation and the format of the image data that is sent 0P None raw data 2P None default for USB 3P Hmodem compressed default for RS232 4P Hmodem S Pixel Ship Pixel Ship sizes an image in proportion to its original size It decimates the image by shipping only certain regularly spaced pixels For e...

Страница 144: ... better JPEG compression than the standard E Edge Sharpen command see page 7 13 This filter also works well when shipping pure black and white images 1 bit per pixel The optimal setting is 26U 0U Document image filter off default 26U Apply document image filter for typical document image nU Apply document image filter using grayscale threshold n Use lower numbers when the image contrast is lower 1...

Страница 145: ...tonal range of an image or key type A low key image has detail concentrated in the shadows a high key image has detail concentrated in the highlights and an average key image has detail concentrated in the midtones This modifier ships the histogram for an image 0W Don t ship histogram default 1W Ship histogram Example of Blur Image Off 0V Example of Blur Image On 1V Image used for histogram Histog...

Страница 146: ...l size of the signature area as well as specify how far the signature area is from the bar code vertically and horizontally You can also set the resolution and file format for the final output of the signature capture image Note IMGBOX commands can only be triggered by one of the following types of bar codes PDF417 Code 39 Code 128 Aztec Codabar and Interleaved 2 of 5 Once one of these symbologies...

Страница 147: ...an image to the host To see this example align the signature area not the bar code in the center of the image then press the trigger Send the following IMGBOX command string after the button push Example IMGBOX245w37h55y Note Case is not important in the command string It is used here only for clarity The following image is captured The IMGBOX commands have many different modifiers that can be use...

Страница 148: ...ether it will be grayscale or black and white 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and white image F File Format This option indicates the type of file format in which to save the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed Binary 5F Uncompressed grayscale 6F JPEG image default 7F Outlined image Example of I...

Страница 149: ...darker the image The optimal setting for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image nK Apply gamma correction factor n n 0 1000 R Resolution of Signature Capture Area The resolution is the number of pixels that the engine outputs per each min imum bar width The higher the value for R the higher the quality of the image but a...

Страница 150: ...e Area The width of the signature capture area must be measured in inches divided by 01 In the example the width of the area to be captured is 2 4 inches resulting in a value of W 2 4 0 01 240 A value of 245 was used in the example to accommodate a slightly wider image area X Horizontal Bar Code Offset The horizontal bar code offset allows you to offset the horizontal center of the signature captu...

Страница 151: ... of the signature capture area Negative numbers indicate that the signature cap ture is above the bar code and positive numbers indicate that the area is below the bar code Measurements are in multiples of the minimum bar width Example of Vertical Offset set to 7Y Example of Vertical Offset set to 65Y ...

Страница 152: ...7 20 ...

Страница 153: ...used with the engine Refer to page 2 13 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Страница 154: ...IBM AT XT and PS 2 Compatibles WYSE PC AT Supported Keys IBM XTs and Compatibles Supported Keys IBM DDC Memorex Telex Harris Supported Keys NUL 00 Reserved Reserved Reserved SOH 01 Enter KP CR Enter Enter STX 02 Cap Lock Caps Lock F11 ETX 03 ALT make Reserved F12 EOT 04 ALT break Reserved F13 ENQ 05 CTRL make Reserved F14 ACK 06 CTRL break Reserved F15 BEL 07 CR Enter CR Enter New Line BS 08 Reser...

Страница 155: ...5 ESC 1B F6 F6 F6 FS 1C F7 F7 F7 GS 1D F8 F8 F8 RS 1E F9 F9 F9 US 1F F10 F10 F10 IBM 3191 92 3471 72 3196 97 3476 77 Telex all models ASCII HEX IBM Memorex Telex 102 Supported Keys Memorex Telex 88 Supported Keys NUL 00 Reserved Reserved SOH 01 Enter Enter STX 02 F11 PF10 ETX 03 F12 PF11 EOT 04 F13 PF12 ENQ 05 F14 Reserved ACK 06 F15 Reserved BEL 07 New Line New Line BS 08 F16 Field Forward ASCII ...

Страница 156: ... F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 RS 1E F9 PF9 US 1F F10 Home IBM 3196 97 3476 77 3191 92 3471 72 Memorex Telex all models with 102 key keyboards Memorex Telex with 88 key keyboards ASCII HEX Esprit 200 400 ANSI Supported Keys Esprit 200 400 ASCII Supported Keys Esprit 200 400 PC Supported Keys NUL 00 Reserved Reserved Reserved S...

Страница 157: ...11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12 F12 F12 SYN 16 F1 F1 F1 ETB 17 F2 F2 F2 CAN 18 F3 F3 F3 EM 19 F4 F4 F4 SUB 1A F5 F5 F5 ESC 1B F6 F6 F6 FS 1C F7 F7 F7 GS 1D F8 F8 F8 RS 1E F9 F9 F9 US 1F F10 F10 F10 ASCII HEX Apple Mac iMac Supported Keys NUL 00 Reserved SOH 01 Enter Numpad Enter ASCII HEX...

Страница 158: ...09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACKSPACE ASCII HEX Apple Mac iMac Supported Keys ...

Страница 159: ...ymbologies This is a temporary setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial num ber an...

Страница 160: ...addition the content of that programming code is output to the terminal Note This feature should not be used during normal engine operation TotalFreedom TotalFreedom is an open system architecture that makes it possible for you cre ate applications that reside on your engine Two types of apps can be created using TotalFreedom Decoding and Data Formatting For further information about TotalFreedom ...

Страница 161: ...nd create and print programming bar codes Using EZConfig you can even save open the programming parameters for an engine This saved file can be e mailed or if required you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location Users in other locations can scan the bar code to load in the custom ized programming To communic...

Страница 162: ... engine can perform You can capture an image using the current settings and the image will be displayed in an image window Images captured from the engine can be saved to files in different image formats You can modify the image settings and save the image settings to an INI file which can be loaded later to capture new images Imaging also lets you preview the images continuously captured by the e...

Страница 163: ... screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS 232 configuration settings are identified with a Tag of 232 SubTag A 3 ch...

Страница 164: ...ce of a SubTag field the query applies only to the subset of commands available that match the Tag field In this case the Data field should not be used because it is ignored by the device Data Field Usage When a query is used in place of the Data field the query applies only to the specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be ...

Страница 165: ...indicates that Codabar Coding Enable CBRENA has a range of values from 0 to 1 off and on Example What is the default value for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the default setting for Codabar Coding Enable CBRENA is 1 or on Example What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indic...

Страница 166: ...cans until a bar code has been read until the deactivate command is sent or until the serial time out has been reached see Read Time Out on page 3 7 for a description and the serial command on page 10 13 Resetting the Custom Defaults If you want the custom default settings restored to your engine scan the Acti vate Custom Defaults bar code below This resets the engine to the custom default setting...

Страница 167: ...stom Defaults DEFALT 1 7 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 1 7 Activate Defaults DEFALT 1 7 Programming the Interface Plug and Play Codes RS232 Serial Port PAP232 2 1 Plug and Play Codes USB USB Keyboard PC PAP124 2 1 USB Serial TERMID130 2 2 CTS RTS Emulation On USBCTS1 2 2 CTS RTS Emulation Off USBCTS0 2 2 ACK NAK Mode On USBACK1 2 2 ACK NAK Mode Off USBACK0 2 2 Verifo...

Страница 168: ...m KBDCTY1 2 4 Bosnia KBDCTY33 2 4 Brazil KBDCTY16 2 4 Brazil MS KBDCTY59 2 5 Bulgaria Cyrillic KBDCTY52 2 5 Bulgaria Latin KBDCTY53 2 5 Canada French legacy KBDCTY54 2 5 Canada French KBDCTY18 2 5 Canada Multilingual KBDCTY55 2 5 Croatia KBDCTY32 2 5 Czech KBDCTY15 2 5 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 169: ... KBDCTY64 2 6 Greek 220 KBDCTY61 2 6 Greek 319 Latin KBDCTY65 2 6 Greek 319 KBDCTY62 2 6 Greek Latin KBDCTY63 2 6 Greek MS KBDCTY66 2 6 Greek Polytonic KBDCTY60 2 7 Hebrew KBDCTY12 2 7 Hungarian 101 key KBDCTY50 2 7 Hungary KBDCTY19 2 7 Iceland KBDCTY75 2 7 Irish KBDCTY73 2 7 Italian 142 KBDCTY56 2 7 Italy KBDCTY5 2 7 Japan ASCII KBDCTY28 2 7 Kazakh KBDCTY78 2 7 Kyrgyz Cyrillic KBDCTY79 2 7 Latin ...

Страница 170: ...a KBDCTY26 2 8 Russian MS KBDCTY67 2 9 Russian Typewriter KBDCTY68 2 9 SCS KBDCTY21 2 9 Serbia Cyrillic KBDCTY37 2 9 Serbia Latin KBDCTY36 2 9 Slovakia KBDCTY22 2 9 Slovakia QWERTY KBDCTY49 2 9 Slovakia QWERTZ KBDCTY48 2 9 Slovenia KBDCTY31 2 9 Spain KBDCTY10 2 9 Spanish variation KBDCTY51 2 9 Sweden KBDCTY23 2 9 Switzerland French KBDCTY29 2 9 Switzerland German KBDCTY6 2 10 Tatar KBDCTY85 2 10 T...

Страница 171: ...sion Keyboard Conversion Off KBDCNV0 2 12 Convert all Characters to Upper Case KBDCNV1 2 12 Convert all Characters to Lower Case KBDCNV1 2 12 Keyboard Style Regular KBDSTY0 2 11 Caps Lock KBDSTY1 2 11 Shift Lock KBDSTY2 2 11 Automatic Caps Lock KBDSTY6 2 11 Emulate External Keyboard KBDSTY5 2 12 Control Character Output Control Character Output Off KBDNPE0 2 13 Control Character Output On KBDNPE1 ...

Страница 172: ...eypad Off KBDNPS0 2 14 Numeric Keypad On KBDNPS1 2 14 Auto Direct Connect Off KBDADC0 2 14 Auto Direct Connect On KBDADC1 2 14 Baud Rate 300 BPS 232BAD0 2 15 600 BPS 232BAD1 2 15 1200 BPS 232BAD2 2 15 2400 BPS 232BAD3 2 15 4800 BPS 232BAD4 2 15 9600 BPS 232BAD5 2 15 19200 BPS 232BAD6 2 15 38400 BPS 232BAD7 2 15 57600 BPS 232BAD8 2 15 115200 BPS 232BAD9 2 15 Selection Setting Indicates default Seri...

Страница 173: ...2WRD5 2 16 8 Data 1 Stop Parity None 232WRD2 2 16 8 Data 1 Stop Parity Odd 232WRD8 2 16 RS232 Receiver Time out Range 0 300 seconds 232LPT 2 17 RS232 Handshaking RTS CTS Off 232CTS0 2 17 Flow Control No Timeout 232CTS1 2 17 Two Direction Flow Control 232CTS2 2 17 Flow Control with Timeout 232CTS3 2 17 RS232 Timeout 232DEL 2 18 XON XOFF Off 232XON0 2 18 XON XOFF On 232XON1 2 18 ACK NAK Off 232ACK0 ...

Страница 174: ...VL3 3 3 Beeper Pitch Good Read Frequency Low 1600 min 400Hz BEPFQ11600 3 3 Medium 2700 BEPFQ12700 3 3 High 4200 max 9000Hz BEPFQ14200 3 3 Beeper Pitch Error Frequency Razz 250 min 200Hz BEPFQ2800 3 4 Medium 3250 BEPFQ23250 3 4 High 4200 max 9000Hz BEPFQ24200 3 4 Beeper Duration Good Read Normal Beep BEPBIP0 3 4 Short Beep BEPBIP1 3 4 LED Good Read Off BEPLED0 3 4 On BEPLED1 3 4 Number of Beeps Err...

Страница 175: ...er Enhanced PAPHHS 3 7 Serial Trigger Mode Read Time Out 0 300 000 ms 30 000 TRGSTO 3 7 Image Snap and Ship Image Snap and Ship TRGMOD6 3 8 Reread Delay Short 500 ms DLYRRD500 3 8 Medium 750 ms DLYRRD750 3 8 Long 1000 ms DLYRRD1000 3 8 Extra Long 2000 ms DLYRRD2000 3 8 User Specified Reread Delay Range 0 30 000 ms DLYRRD 3 9 Illumination Lights Lights On SCNLED1 3 9 Lights Off SCNLED0 3 9 Selectio...

Страница 176: ...ow Priority Symbology PRFBLK 3 12 Preferred Symbology Timeout 500 Range 100 3000 PRFPTO 3 12 Preferred Symbology Default PRFDFT 3 12 Output Sequence Editor Enter Sequence SEQBLK 3 15 Default Sequence SEQDFT 3 15 Partial Sequence Transmit Partial Sequence SEQTTS1 3 16 Discard Partial Sequence SEQTTS0 3 16 Require Output Sequence Required SEQ_EN2 3 16 On Not Required SEQ_EN1 3 16 Off SEQ_EN0 3 16 Mu...

Страница 177: ...3 Suffix Add Suffix SUFBK2 4 4 Clear One Suffix SUFCL2 4 4 Clear All Suffixes SUFCA2 4 4 Function Code Transmit Enable RMVFNC0 4 4 Disable RMVFNC1 4 4 Intercharacter Delay Range 0 1000 5ms increments DLYCHR 4 5 User Specified Intercharacter Delay Delay Length 0 1000 5ms increments DLYCRX 4 5 Character to Trigger Delay DLY_XX 4 5 Interfunction Delay Range 0 1000 5ms increments DLYFNC 4 6 Intermessa...

Страница 178: ...ired Keep Prefix Suffix DFM_EN2 5 9 Data Formatter On Not Required Drop Prefix Suffix DFM_EN3 5 9 Data Format Required Drop Prefix Suffix DFM_EN4 5 9 Data Format Non Match Error Tone Data Format Non Match Error Tone On DFMDEC0 5 10 Data Format Non Match Error Tone Off DFMDEC1 5 10 Primary Alternate Data Formats Primary Data Format ALTFNM0 5 10 Data Format 1 ALTFNM1 5 10 Data Format 2 ALTFNM2 5 10 ...

Страница 179: ...3 Off CBRENA0 6 3 On CBRENA1 6 3 Codabar Start Stop Char Don t Transmit CBRSSX0 6 3 Transmit CBRSSX1 6 3 Codabar Check Char No Check Char CBRCK20 6 4 Validate But Don t Transmit CBRCK21 6 4 Validate and Transmit CBRCK22 6 4 Codabar Concatenation Off CBRCCT0 6 4 On CBRCCT1 6 4 Require CBRCCT2 6 4 Codabar Message Length Minimum 2 60 4 CBRMIN 6 5 Maximum 2 60 60 CBRMAX 6 5 Code 39 Default All Code 39...

Страница 180: ...ceutical PARAF Off C39B320 6 8 On C39B321 6 8 Code 39 Full ASCII Off C39ASC0 6 9 On C39ASC1 6 9 Code 39 Code Page C39DCP 6 10 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 6 10 Off I25ENA0 6 10 On I25ENA1 6 10 Interleaved 2 of 5 Check Digit No Check Char I25CK20 6 11 Validate But Don t Transmit I25CK21 6 11 Validate and Transmit I25CK22 6 11 Interleaved 2 of 5 Message Length Mi...

Страница 181: ...NA0 6 14 On C93ENA1 6 15 Code 93 Message Length Minimum 0 80 0 C93MIN 6 14 Maximum 0 80 80 C93MAX 6 14 Code 93 Code Page C93DCP 6 15 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 6 15 Off R25ENA0 6 15 On R25ENA1 6 15 Straight 2 of 5 Industrial Message Length Minimum 1 48 4 R25MIN 6 15 Maximum 1 48 48 R25MAX 6 15 Straight 2 of 5 IATA Default All Straight 2 of 5 I...

Страница 182: ...A0 6 18 On C11ENA1 6 18 Code 11 Check Digits Required 1 Check Digit C11CK20 6 18 2 Check Digits C11CK21 6 18 Code 11 Message Length Minimum 1 80 4 C11MIN 6 19 Maximum 1 80 80 C11MAX 6 19 Code 128 Default All Code 128 Settings 128DFT 6 19 Off 128ENA0 6 19 On 128ENA1 6 19 ISBT Concatenation Off ISBENA0 6 20 On ISBENA1 6 20 Code 128 Message Length Minimum 0 80 0 128MIN 6 20 Maximum 0 90 80 128MAX 6 2...

Страница 183: ...Minimum 1 60 1 TELMIN 6 24 Maximum 1 60 60 TELMAX 6 24 UPC A Default All UPC A Settings UPADFT 6 24 Off UPAENA0 6 24 On UPAENA1 6 24 UPC A Check Digit Off UPACKX0 6 24 On UPACKX1 6 24 UPC A Number System Off UPANSX0 6 25 On UPANSX1 6 25 UPC A 2 Digit Addenda Off UPAAD20 6 25 On UPAAD21 6 25 UPC A 5 Digit Addenda Off UPAAD50 6 25 On UPAAD51 6 25 UPC A Addenda Required Not Required UPAARQ0 6 25 Requ...

Страница 184: ...tor On UPEADS1 6 28 Off UPEADS0 6 28 UPC E0 Check Digit Off UPECKX0 6 28 On UPECKX1 6 28 UPC E0 Number System Off UPENSX0 6 29 On UPENSX1 6 29 UPC E0 Addenda 2 Digit Addenda On UPEAD21 6 29 2 Digit Addenda Off UPEAD20 6 29 5 Digit Addenda On UPEAD51 6 29 5 Digit Addenda Off UPEAD50 6 29 UPC E1 Off UPEEN10 6 30 On UPEEN11 6 30 EAN JAN 13 Default All EAN JAN Settings E13DFT 6 30 Off E13ENA0 6 30 On ...

Страница 185: ...lt All EAN JAN 8 Settings EA8DFT 6 33 Off EA8ENA0 6 33 On EA8ENA1 6 33 EAN JAN 8 Check Digit Off EA8CKX0 6 33 On EA8CKX1 6 33 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 6 34 2 Digit Addenda On EA8AD21 6 34 5 Digit Addenda Off EA8AD50 6 34 5 Digit Addenda On EA8AD51 6 34 EAN JAN 8 Addenda Required Not Required EA8ARQ0 6 34 Required EA8ARQ1 6 34 EAN JAN 8 Addenda Separator Off EA8ADS0 6 34 On EA8...

Страница 186: ... 36 Validate Type 10 then Type 11 Char and Transmit MSICHK5 6 36 Disable MSI Check Characters MSICHK6 6 36 MSI Message Length Minimum 4 48 4 MSIMIN 6 36 Maximum 4 48 48 MSIMAX 6 36 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 6 37 Off RSSENA0 6 37 On RSSENA1 6 37 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 6 37 Off RSLENA0 6 37 On RSLE...

Страница 187: ...block A Settings CBADFT 6 39 Off CBAENA0 6 39 On CBAENA1 6 39 Codablock A Msg Length Minimum 1 600 1 CBAMIN 6 40 Maximum 1 600 600 CBAMAX 6 40 Codablock F Default All Codablock F Settings CBFDFT 6 39 Off CBFENA0 6 41 On CBFENA1 6 41 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 6 41 Maximum 1 2048 2048 CBFMAX 6 41 PDF417 Default All PDF417 Settings PDFDFT 6 42 On PDFENA1 6 42 Off PDFENA0 6 42 Sel...

Страница 188: ... On COMUPC1 6 44 Off COMUPC0 6 44 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 6 44 Maximum 1 2435 2435 COMMAX 6 44 GS1 Emulation GS1 128 Emulation EANEMU1 6 45 GS1 DataBar Emulation EANEMU2 6 45 GS1 Code Expansion Off EANEMU3 6 45 EAN8 to EAN13 Conversion EANEMU4 6 45 GS1 Emulation Off EANEMU0 6 45 TCIF Linked Code 39 On T39ENA1 6 46 Off T39ENA0 6 46 QR Code Default All QR Code Settings...

Страница 189: ...Matrix Code Page Data Matrix Code Page 51 IDMDCP 6 49 MaxiCode Default All MaxiCode Settings MAXDFT 6 49 On MAXENA1 6 49 Off MAXENA0 6 49 MaxiCode Msg Length Minimum 1 150 1 MAXMIN 6 49 Maximum 1 150 150 MAXMAX 6 49 Aztec Code Default All Aztec Code Settings AZTDFT 6 50 On AZTENA1 6 50 Off AZTENA0 6 50 Aztec Code Msg Length Minimum 1 3832 1 AZTMIN 6 50 Maximum 1 3832 3832 AZTMAX 6 50 Aztec Code Pa...

Страница 190: ...POSTAL0 6 52 Single 2D Postal Codes Australian Post On POSTAL1 6 52 British Post On POSTAL7 6 52 Canadian Post On POSTAL30 6 52 Intelligent Mail Bar Code On POSTAL10 6 52 Japanese Post On POSTAL3 6 52 KIX Post On POSTAL4 6 52 Planet Code On POSTAL5 6 52 Postal 4i On POSTAL9 6 52 Postnet On POSTAL6 6 53 Postnet with B and B Fields On POSTAL11 6 53 InfoMail On POSTAL2 6 53 Selection Setting Indicate...

Страница 191: ...l Bar Code and Postnet with B and B Fields On POSTAL20 6 53 Postnet and Postal 4i On POSTAL14 6 53 Postnet and Intelligent Mail Bar Code On POSTAL16 6 53 Postal 4i and Intelligent Mail Bar Code On POSTAL17 6 53 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 192: ... POSTAL21 6 54 Planet Postnet and Intelligent Mail Bar Code On POSTAL22 6 54 Planet Postal 4i and Intelligent Mail Bar Code On POSTAL23 6 54 Postnet Postal 4i and Intelligent Mail Bar Code On POSTAL24 6 54 Planet Postal 4i and Postnet with B and B Fields On POSTAL25 6 54 Planet Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL26 6 54 Postal 4i Intelligent Mail Bar Code and Postne...

Страница 193: ...Linear China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings CPCDFT 6 55 Off CPCENA0 6 56 On CPCENA1 6 56 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 6 56 Maximum 2 80 80 CPCMAX 6 56 Korea Post Default All Korea Post Settings KPCDFT 6 57 Off KPCENA0 6 57 On KPCENA1 6 57 Korea Post Msg Length Minimum 2 80 4 KPCMIN 6 57 Maximum 2 80 48 KPCMAX 6 57 Korea Post C...

Страница 194: ...2 Wait for Trigger On SNPTRG1 7 2 LED State Off SNPLED0 7 2 LED State On SNPLED1 7 2 Exposure 1 7874 microseconds SNPEXP 7 3 Gain None SNPGAN1 7 3 Gain Medium SNPGAN2 7 3 Gain Heavy SNPGAN4 7 3 Gain Maximum SNPGAN8 7 3 Target White Value 0 255 125 SNPWHT 7 4 Delta for Acceptance 0 255 25 SNPDEL 7 4 Update Tries 0 10 6 SNPTRY 7 4 Target Set Point Percentage 1 99 50 SNPPCT 7 4 Selection Setting Indi...

Страница 195: ...G IMGFMT6 7 7 File Format KIM IMGFMT0 7 7 File Format TIFF binary IMGFMT1 7 7 File Format TIFF binary group 4 compressed IMGFMT2 7 7 File Format TIFF grayscale IMGFMT3 7 7 File Format Uncompressed binary IMGFMT4 7 7 File Format Uncompressed grayscale IMGFMT5 7 7 File Format BMP IMGFMT8 7 7 Histogram Stretch Off IMGHIS0 7 8 Histogram Stretch On IMGHIS1 7 8 Noise Reduction Off IMGFSP0 7 9 Noise Redu...

Страница 196: ... Off IMGGAM0 7 10 Gamma Correction On 0 1000 IMGGAM 7 10 Image Crop Left 0 640 0 IMGWNL 7 10 Image Crop Right 0 640 639 IMGWNR 7 10 Image Crop Top 0 480 0 IMGWNT 7 10 Image Crop Bottom 0 480 479 IMGWNB 7 11 Image Crop Margin 1 238 0 IMGMAR 7 11 Protocol None raw IMGXFR0 7 11 Protocol None default USB IMGXFR2 7 11 Protocol Hmodem Compressed IMGXFR3 7 11 Protocol Hmodem IMGXFR4 7 11 Ship Every Pixel...

Страница 197: ...age Filter On 0 255 IMGUSH 7 12 Don t Ship Histogram IMGHST0 7 13 Ship Histogram IMGHST1 7 13 Image Size Compatibility Force VGA Resolution IMGVGA1 7 14 Native Resolution IMGVGA0 7 14 Intelligent Signature Capture Optimize On DECBND1 7 14 Optimize Off DECBND0 7 14 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Страница 198: ...10 36 ...

Страница 199: ... cable is connected properly The host system power is on if external power isn t used Is the engine having trouble reading your symbols If the engine isn t reading symbols well check that the symbols Aren t smeared rough scratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the engine or in the decoder to which the engine connects Is the bar code di...

Страница 200: ... Reprogram the engine with the proper symbology selections See Chapter 6 The engine won t read your bar code at all 1 Scan the sample bar codes in the back of this manual If the engine reads the sample bar codes check that your bar code is readable Verify that your bar code symbology is enabled see Chapter 6 2 If the engine still can t read the sample bar codes scan All Symbologies on page 6 2 If ...

Страница 201: ...oduct Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty or non warranty service please visit www honeywellaidc com and select Support Contact Service and Repair to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the p...

Страница 202: ...EPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT INCIDENTAL OR CONSE QUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CON TRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT THE...

Страница 203: ...Codabar Fm 0 1 a 0x61 Codablock A O6 0 1 4 5 6 V 0x56 Codablock F Om 0 1 4 5 6 q 0x71 Code 11 H3 h 0x68 Code 128 Cm 0 1 2 4 j 0x6A GS1 128 C1 I 0x49 Code 32 Pharmaceutical PARAF X0 0x3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 including Bookland EAN E0 d 0x64 EAN 13 with Add On E3 d 0x64 ...

Страница 204: ... 3 5 R 0x52 MSI Mm 0 g 0x67 NEC 2 of 5 X0 Y 0x59 OCR MICR E 13 B o3 O 0x4F OCR SEMI Font o3 O 0x4F OCR A o1 O 0x4F OCR B o2 O 0x4F PDF417 Lm 0 2 r 0x72 Planet Code X0 L 0x4C Postal 4i X0 N 0x4E Postnet X0 P 0x50 QR Code and Micro QR Code Qm 0 6 s 0x73 Straight 2 of 5 IATA Rm 0 1 3 f 0x66 Straight 2 of 5 Industrial S0 f 0x66 TCIF Linked Code 39 TLC39 L2 T 0x54 Telepen Bm t 0x54 UPC A E0 c 0x63 UPC ...

Страница 205: ...tries for specific symbologies override the universal All Symbologies 99 entry Refer to Data Editing beginning on page 4 1 and Data Formatting beginning on page 5 1 for information about using Code ID and AIM ID UPC A with Extended Coupon Code E3 c 0x63 UPC E E0 E 0x45 UPC E with Add On E3 E 0x45 UPC E1 X0 E 0x45 Symbology AIM ID Possible AIM ID Modifiers m Code ID hex ...

Страница 206: ...MENT NAK 6 6 ACKNOWLEDGE ACK 22 16 SYNCHRONIZE SYN 7 7 BEEP BEL 23 17 END OF TRANSMISSION BLOCK ETB 8 8 BACKSPACE BS 24 18 CANCEL CAN 9 9 HORIZONTAL TAB HT 25 19 END OF MEDIUM EM 10 A LINE FEED LF 26 1A SUBSTITUTE SUB 11 B VERTICAL TAB VT 27 1B ESCAPE ESC 12 C FF FORM FEED 28 1C FILE SEPARATOR FS RIGHT ARROW 13 D CR CARRIAGE RETURN 29 1D GROUP SEPARATOR GS LEFT ARROW 14 E SO SHIFT OUT 30 1E RECORD...

Страница 207: ... 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F DEL Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character 128 80 171 AB 214 D6 Ö 129 81 172 AC 215 D7 130 82 173 AD 216 D8 Ø 131 83 ƒ 174 AE 217 D9 Ù 132 84 175 AF 218 DA Ú 133 85 176 B0 219 DB Û 134 86 177 B1 220 DC Ü ...

Страница 208: ...48 94 191 BF 234 EA ê 149 95 192 C0 À 235 EB ë 150 96 193 C1 Á 236 EC ì 151 97 194 C2  237 ED í 152 98 195 C3 à 238 EE î 153 99 196 C4 Ä 239 EF ï 154 9A š 197 C5 Å 240 F0 ð 155 9B 198 C6 Æ 241 F1 ñ 156 9C œ 199 C7 Ç 242 F2 ò 157 9D 200 C8 È 243 F3 ó 158 9E ž 201 C9 É 244 F4 ô 159 9F Ÿ 202 CA Ê 245 F5 õ 160 A0 203 CB Ë 246 F6 ö 161 A1 204 CC Ì 247 F7 162 A2 205 CD Í 248 F8 ø 163 A3 206 CE Î 249 F9...

Страница 209: ...gium Replacement Characters 81 ISO 2022 25 Fra French Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Replacement Characters 86 ISO 2022 11 Swi Swiss Replacement Characters 87 ISO 2022 11 UK British Replacement Characters 88 ISO 2022 11 Dan Danish Replacement Characters 89 ISO 2022 11 Nor Norwegian Replacement Characters 90 ISO 2022 11 Spa...

Страница 210: ...A 8 ...

Страница 211: ......

Страница 212: ......

Страница 213: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Страница 214: ...ataBar 01 00123456789012 PDF417 Postnet Car Registration Zip Code Data Matrix QR Code Test Symbol Numbers Matrix 2 of 5 ID tag UPU 4 State J18CUSA8E6N062315014880T 4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ...

Страница 215: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...

Страница 216: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...

Страница 217: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A C B F E D Save Discard Reset ...

Страница 218: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N86XX UG Rev A 3 12 ...

Отзывы: