3 - 3
Current Draw
For RS232: Idle, Standby and Power Off power modes are controlled by the SDRTIM, 232LPT, TRGLPT, and TRGMOD set-
tings. Idle mode is entered when the SDRTIM time-out expires. Standby mode is entered when the SDRTIM and 232LPT time-
outs expire. Power Off mode is entered when the SDRTIM, 232LPT and TRGLPT time-outs expire. Use TRGMOD2 to enable
Power Off mode.
For USB: Standby mode is entered when USB suspends.
(T
A
= 23
°
C
)
Note: The N56XX is compliant with USB power specifications.
1. Average Value
2. Modified interface board with beeper/LED removed used for this measurement, also disconnect 232 cable while measuring
3. Values in parentheses are for white illumination; the rest of values are for red illumination.
Power Mode
Description
3.3V (RS232 w/
Interface Board)
5V (RS232)
5V (USB)
No interface
board connected
I
Inrush
Maximum current spike seen when power
is applied to the N56XX or when the
engine turns on for the first time
610mA
500mA
500mA
I
Peak
Peak current draw when the engine is
scanning (Manual Trigger)
650mA (975mA)
3
433mA
(499mA)
3
458mA (498mA)
3
I
OperatingAverage
Average current draw when the engine is
scanning (Manual Trigger)
530mA (677mA)
3
350mA
(396mA)
3
385mA (402mA)
3
Average current draw when the engine is
scanning (Streaming Presentation Mode
PAPSPN)
310mA (310mA)
3
200mA
(218mA)
3
230mA (230mA)
3
I
Idle
(imager powered
on)
1,2
Maximum current draw while not scanning
or decoding, but power is applied to the
imager. Controlled by the menu
commands SDRTIM and IMGPWR.
120mA
81mA
88mA
I
Idle
(imager powered
off)
1,2
Maximum current draw while power is not
applied to the imager. Controlled by the
menu command IMGPWR.
72mA
54mA
64mA
I
Standby
1,2
Maximum current draw while in standby
mode. For RS232, Standby mode is
entered when the menu command
232LPT expires while in Idle mode. (This
mode is only available in a 232
configuration). For USB, Standby mode is
entered when USB suspends.
3.0mA
2.5mA
2.5mA
I
Power Off
1,2
Current draw while in Power Off mode
(PWRDWN signal is high). Mode is
entered when the menu command
TRGLPT expires while in both Standby
and Manual Low Power (TRGMOD2)
modes. (This mode is only available in a
232 configuration).
.001mA
.001mA
n/a
Содержание N568X
Страница 1: ...N568X N569X Decoded Image Engines Integration Manual ...
Страница 6: ...iv ...
Страница 10: ...viii ...
Страница 18: ...1 8 ...
Страница 20: ...2 2 ...
Страница 30: ...4 2 N56XX Laser Aimer ER lens at 9 27 Window Size Diagram ...
Страница 38: ...4 10 ...
Страница 50: ...5 12 ...
Страница 55: ...A 5 Antenna Polarity Vertical 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Страница 63: ...A 13 Antenna Polarity Horizontal 200MHz 1GHz Range Level dBµV M Frequency Hz Limit ...
Страница 64: ...A 14 Antenna Polarity Vertical 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Страница 65: ...A 15 Antenna Polarity Horizontal 1GHz 2GHz Range Level dBµV M Frequency Hz Limit ...
Страница 66: ...A 16 ...
Страница 70: ...C 2 LED Aimer PCB Assembly GND Pin 6 V Thermocouple ...
Страница 71: ......
Страница 72: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N56XX IM Rev G 12 16 ...