background image

EN

REMOTE CONTROL

The functions work the same as the portable air conditioner's Touch Screen Control Panel.
All key functions can be accessed from the remote control.

USE & OPERATION (CONTINUED)

6



 

Used for adjusting the timer and temperature.
When 

 or 

 key is pressed in cool mode, the 

set temperature is displayed and may be 
adjusted. After 10 seconds the display will 
revert back to room temperature.
Timer setting is available from 1-24 hours by 
pressing the key 

 or 

Press this button to change the operation mode 
in the order of:

ON / OFF

• HIGH  • MEDIUM  • LOW

In running mode: Auto switch off
In stand-by mode: Auto switch on
Press 

 or 

 button to adjust the 

time setting for 1 hour intervals.

Temperature / Timer Set

Mode Control

Power Control

Fan Speed Control

Timer Control

Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries 
with + and - pointing in the proper direction according to the polarity markings.

Use only two AAA or IEC R03 1.5V batteries.
Remove the batteries if the remote control is not in use for a month or longer.
All batteries should be replaced at the same time, do not mix with old batteries.
Properly dispose of used batteries.




Note:

 

Caution:

Cool

Dehumidify

Fan

*Applicable for models with Heating feature only.

Heater*

Содержание MM14 Series

Страница 1: ...Email info jmatek com Web www jmatek com Portable Air Conditioner User Manual Read and save these instructions before use Model MM14 Series MM14CCS MM14CCSBB MM14CCSWW MM14CHCS MM14CHCSBB MM14CHCSWW ...

Страница 2: ...the condensate through the air outlet hose There is no need to empty the drainage tank except in very high humidity conditions Read and follow the instructions carefully EN Follow installation instructions to set up the unit Plug the unit into a properly grounded circuit Important Before installing the unit place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize Manually a...

Страница 3: ...e is needed contact an authorized service agent Unplug the unit when stored or not in use DO NOT run the power cord under carpeting and rugs Use caution to prevent tripping on cord DO NOT use in areas where gasoline paint or other flammable goods are stored Basic safety precautions should always be followed when using electrical appliances This appliance has been manufactured for use in domestic e...

Страница 4: ...ackets are approximatley 72 cm 28 3 inches each allowing you to install to windows and balcony doors of different heights or width INSTALLATION 1 2 3 4 Window Bracket Kit Window Bracket Panel Adapter Hose Connector Plastic Hose 3 Installation Kit Installation Steps 1 Set 1 Piece 1 Piece 1 Piece 3 4 Connect the window bracket to the opposite end of the plastic hose Ensure that all connections are t...

Страница 5: ... the window bracket to the opposite end of the plastic hose Ensure that all connections are tight and installed properly Note Do not install the window bracket to your window This step is required only to adjust it to the size of your window The bracket should be removed from the window after the size is adjusted INSTALLATION 1 2 3 4 5 Window Bracket Kit Window Bracket Panel Adapter Plastic Pin Ho...

Страница 6: ...oner can be installed semi permanently NOTE When the unit is not in use remove the Plastic Hose from the Flange Fixture on the wall and use the included Hole Cover to cover the hole on the wall Fig 1 Fig 2 12 4 9 5 mm In the wooden kickboard of a french window In the wall we recommend you to insulate the section of wall using suitable insulation materials In the window panel Fig 3 1 Install the pl...

Страница 7: ... 50 cm 20 inches away from Do not place the unit in front of curtains or drapes as this could obstruct the airflow USE OPERATION TOUCH SCREEN CONTROL PANEL POWER CONTROL The Power Control turns the unit on and off MODE CONTROL 3 settings Cool Dehumidify Fan A light will indicate which setting is currently being used 1 Timer Control 4 Mode Control 2 Fan Speed Control 5 Power Control 3 Timer Tempera...

Страница 8: ...run in air conditioning mode AUTO TURN ON When unit is in a standby mode plugged in with power light on then press the or button to select the number of hours until you want the unit to automatically start running TEMPERATURE TIMER SET CONTROLS WARNING LIGHT Condensed water may accumulate in the unit If the internal tank becomes full the Power Control light will flash and the unit will not operate...

Страница 9: ... HIGH MEDIUM LOW In running mode Auto switch off In stand by mode Auto switch on Press or button to adjust the time setting for 1 hour intervals Temperature Timer Set Mode Control Power Control Fan Speed Control Timer Control Battery Installation Remove the cover on the back of the remote control and insert two AAA batteries with and pointing in the proper direction according to the polarity marki...

Страница 10: ...de for 30 minutes before storing Turn off and unplug the air conditioner from the power supply Remove the air filter and clean with water Dry the air filter and then reinstall onto the unit Disconnecting the Window Installation Kit Cover the air conditioner with a cloth plastic bag before storage to protect from dust and scratches collecting on the surface of the unit It is recommended to coil the...

Страница 11: ... 2 3 4 5 6 Unplug the unit from power source Place a shallow pan under the lower drain plug See diagram Remove the lower drain plug Water will drain out and collect in the shallow pan After the water is drained replace the lower drain plug firmly You can now turn on the unit 1 2 3 4 5 Unplug the unit from the power source Remove the upper drain plug While doing this operation some residual water m...

Страница 12: ...cted Connect exhaust hose as per instructions on page 4 Runs but no cooling A door or window is open The air filter is dirty The exhaust hose is detached Temperature setting is too high Air outlet or intake is blocked Make sure the window or door is closed Clean the air filter Reinstall exhaust hose properly refer to Installation section Reduce temperature setting on control panel Remove blockage ...

Страница 13: ...ek com Web www jmatek com 2015 JMATEK Limited All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to these products These products are manufactured by JMATEK Limited ...

Отзывы: