background image

 

 

Instructions for use 

MICRO-K

 

GBR  

 

NU034-09 

1779816-06/14 

 

INTRODUCTION

 

 

 
The  MICRO-K  is  a  self-contained,  closed  circuit,  isolating  breathing  apparatus  intended  to  enable 
evacuation or emergency clearance of people during a forest fire where the air becomes unbreathable. This 
apparatus comprises a KO2 cartridge and a breathing bag mounted on a half-face mask. The assembly is 
sealed  in  an  airtight  aluminised  plastic  bag  and  stored  in  a  portable  canvass  bag  worn  on  the  belt.  This 
system provides the wearer with an oxygen supply for more than 6 minutes. 
 
 

LIMITATIONS FOR USE

 

 

 

The  MICRO-K  is  only  intended  for  evacuating  firemen  fighting  forest  fires. 

It  is  a  single  use  device; 

after  use  it  must  be  discarded  or  reconditioned  by  qualified  staff.  The  MICRO-K  must  only  be  worn  by 
people having undertaken practical training and appropriate practice. For this training use MICRO-K training 
apparatus  reference  1799002  or  1799011  (with  hooks  for  helmet  F2).  To  distinguish  them  from  standard 
MICRO-K apparatus, these training devices are packed in an orange bag. 

The MICRO-K must only be used in the open air.

 

 

INSTRUCTIONS FOR USE

   

 
The wearer should apply the following procedure when in an unbreathable atmosphere: 

 

Open the MICRO-K canvass bag. 

 

If the bag contains a "PONCHO" (option), take it out and put it on. 

 

Take out the aluminised film bag containing the MICRO-K. 

 

Tear open the aluminised bag: a tearing guide is provided on the top of the bag. 

 

Put the half-face mask on the face: pointed part uppermost. 

 

Without  removing  the  helmet,  pass  the  elastomeric  strap  over  the  head,  positioning  the  strap  on  the 
nape of the neck. 

 

If the user is not wearing a helmet, proceed in the same way and then tighten the assembly by pulling 
the ends of the strap. 

 

If  the  Micro-K has hooks, pass the elastomeric strap over the helmet and position it in the nape of the 
neck. Insert the hooks into the appropriate parts of the helmet. Now tighten it by pulling forwards on the 
ends of the strap. 

 

Breathe in and out deeply in order to inflate the breathing bag. 

 

Breathe normally and leave the area where breathing was impossible. 

 

 

Warnings 

 

 

It  is  normal  for  the  temperature  of  breathed  air  to  increase;  do  not  remove  the  apparatus 
under any circumstances. 

 

Always  make  sure  that  the  respiratory  protection  equipment  is  suitable  for  the  risks 
experienced. 

 

Any apparatus with a broken seal and/or torn aluminised film bag must be repackaged after 
changing the KO2 cartridge. 

 

KO2 extensively exposed to the air absorbs moisture from it and deteriorates into a strongly 
alkaline brine. As a result, to avoid the risk of burns, an apparatus with a punctured or torn 
aluminised bag must never be used. 

 

The  MICRO-K  must  not  be  used  to  evacuate  premises,  as  fire-fighting  equipment  or  an 
protective equipment for men working. 

 

 

MAINTENANCE, STORAGE

 

 

Maintenance

 

This apparatus is for single use only and as a result requires no maintenance. 
 

Periodic check. 

The periodic check consists of confirming that the apparatus has not taken in moisture. To do this: 

 

Open the canvass bag and take out the apparatus packed in its aluminised film bag. 

 

Schedule for checks 

Stored apparatus 

Before putting into storage, then every year. 
Before putting into use. 

Apparatus carried 

Monthly if there is no fire fighting activity. 
Before and after each fire fighting activity. 

 

Storage 

Maximum storage period is 5 years, stored in its undamaged original packaging. 
At the end of this period, the apparatus must be repacked by the 

HONEYWELL RESPIRATORY SAFETY 

PRODUCTS After Sales Service department

 or another approved organisation. 

 

Spare parts 

1799049 

Red plastic seal 

 
 

MEANING OF MARKING

   

 

 

 

 

 

SEE 

INSTRUCTIONS 

FOR USE 

EXPIRY DATE 

MAXIMUM AND MINIMUM 

STORAGE 

TEMPERATURE 

MAXIMUM 

STORAGE 
HUMIDITY 

 
 
 
 
 
 
 

 

Certification Européenne 

Directive 89/686

 

CIOP, "Centralny Instytut Ochrony Pracy” 

ul. Czerniakowska 16 

07 701 WARSZAWA Poland 

 

 

HONEYWELL RESPIRATORY 

SAFETY PRODUCTS 

ZI Paris Nord II 

– B.P. 50288 

33, rue des Vanesses 

95958 Roissy CDG CEDEX 

France

 

 
 