GB
Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
http://www.hls-nordic.com
The product contains bracket for wall mounting and spacers for ceiling mounting.
Step 3:
Tighten the cable tie around the cables.
Step 4:
Slide the luminaire into the socket. The lock/unlock button appears
indicating that the luminaire is securely installed.
Step 2:
Pass the mains cables through the cable gland. Always use in any
case round mains cable, with a diameter of 5-10mm (H05RN-F
type 2x1mm² or any other type, at least equal to it's mechanical and
electrical properties). ATTENTION!! The cable must not be
deformed in any way (This requirement is important to ensure the
IP rating). Connect the mains to terminal blocks: L for live wire, N for
neutral and PE for ground.
Step 1:
Fasten the mounting part (with screws from within) to either wall bracket (supplied), ceiling (with or without
supplied spacers). If mounted close to a wall make sure, that the
unlock button is facing outwards.
Mouting Methods:
PRESS HERE
TO UNLOCK
PRESS HERE
TO UNLOCK
Power
cable
Power
cable
Metal Wall Bracket
Spacers
Wall Mounting
Ceiling Mounting
At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose of
with your normal household waste. Do not burn.
Technical description
Part no.:
o
-10 to 60 C
Up to 95%
Produced in accordance with:
Ambient Temperature Range:
Maximum Power Consumption:
Operation Voltage:
Relative Humidity:
Technical lifetime (light source):
Lumen output
> 100000 hours
280lm
550lm
850lm
MaxLED 26m
MaxLED 65m
MaxLED 47m
3.1W / 3.8VA
5.4W / 5.9VA
7.7W / 8.2VA
220-240V AC/DC, 50-60 Hz
290253.S10
290255.S10
290254.S10
IP40
Degress of cover protection:
EN 60598-1, EN 60598-2-22, EN 55015
EN 61547, EN 61000-3-2, EN 61000-3-3
Weight:
800 gr
1190 gr
1765 gr
The light source contained in this luminary shall only be replaced by the manufacturer, or his
agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.