New Features and Additional Programming Changes 

 

The LYNXR-I Series Security System includes several new features that must be programmed in accordance 
with this supplement. These features and programming steps are not included in the Installation and Setup 
Guide or the Programming Guide that are provided with this control.  

Please follow the new and revised diagrams and procedures contained in this supplement when installing 
and programming the new features.  

The new LYNXR-I Series features include: 

 

Compatibility with the AlarmNet GSML/GSMVL Communications Devices 

 

New 24-hour Carbon Monoxide Monitor Zone Type 14 and compatibility with the 5800CO Carbon 
Monoxide Sensor. 

 

Remote Services (requires compatible AlarmNet Communications device) 

 

Wiring Overview 

The following diagram provides an overview of the LYNXR-I Series control’s wiring connections. A summary 
of connections diagram is also provided. 

 

09012-009-V0

SUPER HIGH-CAPACITY

BATTERY CONNECTOR

TERMINAL

STRIP

TELEPHONE

CONNECTIONS

LRR/IP

COMMUNICATIONS

PORT

GSML/GSMVL

COMMUNICATIONS

PORT

LOCAL

SOUNDER

DISABLE

STANDARD

HIGH-CAPACITY

BATTERY CONNECTOR

 

 

LYNXR-I Series Wiring Connections 

Содержание LYNXR-I Series

Страница 1: ...is supplement when installing and programming the new features The new LYNXR I Series features include Compatibility with the AlarmNet GSML GSMVL Communications Devices New 24 hour Carbon Monoxide Monitor Zone Type 14 and compatibility with the 5800CO Carbon Monoxide Sensor Remote Services requires compatible AlarmNet Communications device Wiring Overview The following diagram provides an overview...

Страница 2: ... cable provides DC power and ground for the module and data in data out connections 5 If using the GSMVL connect the provided shielded audio cable between the GSMVL module and the control s PC board COMMUNICATIONS CABLE GSMVL ANTENNA 09012 017 V0 SCREW 3 AUDIO CABLE GSMVL ONLY Installing the GSML GSMVL Communications Module GSML GSMVL Programming If you are installing a GSML GSMVL Communications D...

Страница 3: ...ice Capabilities 4 Follow Me System Follow Me Reminder and Pager features are not supported These features will not work if selected in 49 5 Speaker Phone and Remote Phone Access are not available These features should be disabled in 47 and 91 Download over the Phone Line feature is also unavailable 6 AAV mode can be established only on LRR IP Digital Communication with AAV Capabilities 7 If AAV i...

Страница 4: ... 225 seconds in 15 second increments If 0 is entered the control panel will send redundant reports to both Primary Dialer and the LRR IP communications device 2nd Entry The second entry determines the alternate Central Station communication path that will be initiated after the time out period 78 Programmable Tone Generation Time 00 Disabled 01 09 100 900 ms 10 99 1 0 9 9 secs This field is used t...

Страница 5: ...ad address of 1 must be enabled in the communication device in order for the device to talk to the control panel To Select the User Interface Select LYNX Keypad as the User Interface during account programming on the AlarmNet Direct website Multi mode Feature Multi mode enables users to receive e mail notification of system events Since the communication device is emulating a 4204 or two 4204 modu...

Страница 6: ...e start end defaults for Daylight Savings time have been revised The revised defaults are as follows Function Table 1 Table 2 Table 3 Table 4 29 Daylight saving time start end month 3 11 3 11 3 11 3 11 30 Daylight saving time start end weekend 2 1 2 1 2 1 2 1 55 Reporting Channels 0 0 0 0 78 Programmable Tone Generation Time 0 0 0 0 0 0 0 0 86 Multi mode E mail notification 0 0 0 0 80 DEFAULT TABL...

Страница 7: ... OF CONNECTIONS LYNXR I ALSO COMPLIES WITH THE FOLLOWING CANADIAN STANDARDS ASSOCIATION CSA C22 1 CANADIAN ELECTRICAL CODE PART 1 SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN ULC S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS THE LYNXR I CONTROL IS COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATE...

Страница 8: ...2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2008 Honeywell International Inc www honeywell com security ÊK14945TŠ K14945 1 08 Rev A ...

Отзывы: