Honeywell LTE-X series Скачать руководство пользователя страница 4

LTE-X

 

 Series Installation and Setup Guide 

 

– 2 – 

Specifications 

 

Dimensions: 

4 x 7 x 1.75 inches 

Input Voltage: 

12VDC (powered via the ECP bus.) 

Current: 

Standby 25mA,  Transmit 250mA  

Operating temperature: 

–20º to +55ºC, for UL/ULC installations 0ºC to +49ºC 

Storage temperature: 

–40º to +70ºC 

Humidity: 

0 to 95% relative humidity, non-condensing 
(UL installations 0% to 85%; for ULC installations 0% to 93%) 

Altitude: 

to 10,000 ft. operating, to 40,000 ft. storage 

Frequency Bands 

 

LTE 

Band 2 

LTE 

Band 4 

LTE 

Band 5 

LTE 

Band 12 

LTE 

Band 13 

WCDMA 

Band II 

WCDMA 

Band V 

LTE-XV 

 

 

 

 

LTE-XA 

LTE-XC 

Output Power 

LTE,  

Class 3 

23dBm  

WCDMA 

Class 3 

24dBm  

Data Encryption 

The communicator uses 256 bit AES (Rijndael) encryption (which is required for certain government installations).  The 
AlarmNet-i AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval.  
Listings for this approval can be found at https://csrc.nist.gov/Projects/Cryptographic-Algorithm-Validation-
Program/Validation/Validation-List/AES and search for “Certificate number 979. 

 

Remote Services Features 

 

UL

 

Remote Access has not been evaluated by UL. 

 

Honeywell offers secure web based services that enable users to remotely monitor and control their security system.  
These web services enable  
users to: 

 

Monitor and control their security system from a website  

 

Receive e-mail and text message notifications of system events  

 

Control the system and receive confirmations using text messages  

 

Monitor and control IP video cameras 

Dealers can enroll their customers for "Remote Services" by using the AlarmNet 360 website.  Once enabled, the specific 
programming fields associated with these features can be programmed into the communications device either remotely 
using the AlarmNet 360 website or locally using the 7720P programming tool. 

 

E-mail notification (Multi Mode) is intended as a convenience for the user, and does not replace Central 
Station reporting of critical events (alarms, troubles, etc.). 

 

Testing the System 

After installation the security system should be tested.  Refer to the control panel installation instructions for procedures 
to test the entire system. 

Compatibility 

The communicator functions with any control panel that utilizes a Honeywell ECP bus and supports a communicator. 

Содержание LTE-X series

Страница 1: ... X S Se er ri ie es s C Co om mm mu un ni ic ca at to or rs s L LT TE E X XV V L LT TE E X XA A L LT TE E X XC C I In ns st ta al ll la at ti io on n a an nd d S Se et tu up p G Gu ui id de e 800 23340 10 17 Rev B ...

Страница 2: ...Programming Tool 6 Programming Conventions 7 Using the Control Panel 7 Programming 7 Programming Options 7 ECP Status Codes 10 Exiting the Programming Mode 10 Setting Factory Defaults 11 Registering the Communicator 11 Registering through the AlarmNet 360 Website 11 Remote Services Total Connect 12 Registering Using the Test Message Registration Switch 12 Registering Using the 7720P Programming To...

Страница 3: ...antennas provide additional security Simple programming using the 7720P programming tool or via the AlarmNet 360 website Uses 2 way ECP communication with the control panel Sends reports in Contact ID format Supports remote control of alarm system via Remote Services feature Allows uploading and downloading of control panel data Fully powered primary and backup battery from the control panel The L...

Страница 4: ...h for Certificate number 979 Remote Services Features UL Remote Access has not been evaluated by UL Honeywell offers secure web based services that enable users to remotely monitor and control their security system These web services enable users to Monitor and control their security system from a website Receive e mail and text message notifications of system events Control the system and receive...

Страница 5: ...lowing procedure assumes the control panel will be used for power If satisfactory signal strength is present at the control panel that is the preferred mounting location 1 Ensure power to the control panel both AC and battery is off Open the enclosure and connect the ECP cable connector to the communicator Connect the cable wires to the control s ECP terminals 2 Turn power on and wait for the comm...

Страница 6: ...le to the communicator circuit board and thread the wires through the threaded mounting adapter 5 Refer to the control panel s installation guide and complete the ECP cable wiring 6 Secure the wiring with ties as necessary Mounting the Module on the Wall 1 Ensure control panel power both AC and battery is off then remove a suitable knockout on the top or side of the control panel cabinet NOTES If ...

Страница 7: ... wiring to the control panel A control panel knockout that is presently used can be utilized however DO NOT utilize a control panel knockout that is being used for primary power 6 Refer to the installation guide for the control panel and complete the ECP cable wiring 7 Secure the wiring with ties as necessary Programming the Module The LTE X requires an AlarmNet account For new installations pleas...

Страница 8: ...y To perform a Shift function press the shift key then press the appropriate key The following table lists each normal and shift key function 7720P Normal and Shift Key shift LED lit Functions KEY NORMAL KEY FUNCTION SHIFT KEY FUNCTION BS ESC BS Press to delete entry ESC Press to quit program mode also can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO ...

Страница 9: ...e communicator interface on ECP so be sure to check the control panel s Installation and Setup Guide to see if it supports this feature Press the ENTER key to begin programming NOTE The central station can remotely block access to local device programming If this has been done prompt on the right appears Access to Prog Mode Denied The default programming values for each prompt are shown in parenth...

Страница 10: ...ompt 3 Press ESC to load factory defaults Refer to the Exiting the Programming Mode topic 9 Multi Mode Disabled _ Disabled Enhanced Reports Disable for normal alarm processing and go to Prompt 11 Primary City ID prompt Select Enhanced Reports if you want system events sent by e mail to the user Enhanced Reports enables reporting to Total Connect 2 0 web services NOTE To use Enhanced Reports ensure...

Страница 11: ... AlarmNet 360 website 17 Keypad Address 28 _ 01 30 NOTE This prompt will only appear if the Remote Access feature has been enabled Must be programmed if using the Remote Access feature Enter the appropriate device address 18 Supervision 24 Hours _ 30 Day 24 Hour None The AlarmNet network must hear at least one supervisory message from the communicator during this supervision period otherwise Alarm...

Страница 12: ...will display a fault message if any of the events listed below occur Module lost communications with the control panel Module lost contact with AlarmNet Module is not registered account not activated Module shutdown In addition the Contact ID codes for some of these conditions are reported by the control panel and sent by AlarmNet to the central station Exiting the Programming Mode To exit the pro...

Страница 13: ...gistration successfully completes the communicator enters a normal operating mode the REG green LED goes out and the TX RX yellow LED is lit to indicate that the power on reset message is waiting to be sent This message will appear at the receiving station as E339 803 The description may read Trouble Exp Mod Reset If registration is not validated within 90 seconds the communicator times out and th...

Страница 14: ...communicators Enhanced Reports must be enabled Once the dealer assigns a login name and password the customer will receive a Welcome e mail message with their login name along with some helpful information The customer will receive another e mail message with their password They will then be able to receive notifications and access their system via the Total Connect website or using their cell pho...

Страница 15: ... or an error was made in programming the Primary account information of the communicator for an existing account This prompt appears for 2 seconds See the Replacing an existing communicator topic Replacing an existing communicator Enter PIN This prompt appears after pressing the down arrow on the 7720P Enter a 4 digit alphanumeric PIN number provided by your central station your dealer or an autho...

Страница 16: ...he box and inside the communicator Press the Space key to go to the next field Press the BS key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this device Press the Space key to go to the next field Press the BS key to go to the previous field IMEI xxxxxxxx xxxxxx x IMEI Display Displays the identification n...

Страница 17: ...to 12dB 4 stars 13dB to 14dB 3 stars 15dB to 16dB 2 stars 17dB and lower 1 star Press the space key to go to the next screen Press the backspace key to go to the last screen LTE Displays RRAT RSRP RSRQ LTE xxxx xxxx Signal Display for LTE RAT Radio Access Technology RSRP Reference Signal Received Power RSRQ Reference Signal Received Quality Press the space key to get to the next screen Press the b...

Страница 18: ... space key to get to the next screen Press the backspace key to go to the previous field RSCP MIN MAX xxxx xxxx xxxx Min Max Signal Display for LTE RSRP Current Reference Signal Received Power MIN Minimum Receive Signal Level MAX Maximum Receive Signal Level Press the space key to get to the next screen Press the backspace key to go to the previous field Cntry Netw LAC xxx xxx xxxxx Location Displ...

Страница 19: ...ode Pressing Y resets the device Shift UP arrow Registering Registration Registers a programmed communicator with AlarmNet DN arrow Enter PIN Registration with PIN for Replacement Module Registers a replacement communicator with AlarmNet once programmed using the existing PIN 0 Force Server Update Y N Force Upload of Configuration File to Server Pressing Y will force the device to upload its entir...

Страница 20: ...ware update Fail E366 Glossary 4G LTE Refers to the fourth generation Long Term Evolution cellular wireless standards AES Advanced Encryption Standard CRC Cyclic Redundancy Check used to confirm validity of MAC ID ECP Enhanced Console Protocol is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices It uses four wires power ground data in data out IM...

Страница 21: ...LTE X Series Installation and Setup Guide 19 NOTES ...

Страница 22: ...LTE X Series Installation and Setup Guide 20 NOTES ...

Страница 23: ...ending QUICK PERIODIC BLINK Normal FAST BLINK Message waiting for network ACK SLOW BLINK In unison with green LED Registration in progress FAULT red ON No contact with network OFF Normal SLOW BLINK Loss of communication with the panel ECP fault FAST BLINK No network contact AND loss of communication with the control panel SIGNAL green ON Minimum required signal strength is present OFF Installation...

Страница 24: ...mful interference and 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d ISED Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interférences nuisibles 2 Cet appareil doit accepter toute interférence reçue y com...

Отзывы: