Honeywell LTE-X series Скачать руководство пользователя страница 24

 

 

 

 

FEDERAL COMMUNICATIONS COMMISSION & ISED STATEMENTS 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized 
changes or modifications could void the user's authority to operate the equipment.

 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: 

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's 
instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing 
device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a 
residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to 
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures: 

 

If using an indoor antenna, have a quality outdoor antenna installed. 

 

Reorient the receiving antenna until interference is reduced or eliminated. 

 

Move the radio or television receiver away from the receiver/control. 

 

Move the antenna leads away from any wire runs to the receiver/control. 

 

Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. 

 

Consult the dealer or an experienced radio/TV technician for help. 

ISED CLASS B STATEMENT 

This Class B digital apparatus complies with Canadian ICES-003. 

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 

FCC / ISED STATEMENT 

This device complies with Part 15 of the FCC Rules, and ISED’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’ISED. Son fonctionnement est soumis aux conditions suivantes: (1) 
Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une 
réception indésirable. 

 

 

RF EXPOSURE 

Warning 

– The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not 

be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC and ISED multi-transmitter product procedures. 

Mise en Garde 

Exposition aux Fréquences Radio : 

La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent être installée(s) à une distance de séparation d'au moins 20 

cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner parallèlement à tout autre transmetteur ou antenne, excepté en conformité avec les 
procédures de produit multi transmetteur FCC et ISED.

 

 

Important Note About External Antennas 

If an external cellular radio antenna is used, the antenna may be installed or replaced ONLY by a professional installer.  

 

To the Installer

 

LTE-XV: The external antenna gain shall not exceed 6.94 dBi for 700 MHz, 6.00 dBi for 1700 MHz, 9.01 dBi for 1900 MHz. Under no conditions may an 
antenna gain be used that would exceed the ERP and EIRP power limits as specified in FCC Parts 22H, 24E and 27. 
LTE-XC, LTE-XA: The external antenna gain shall not exceed 6.63 dBi for 700MHz & 850MHz, 6 dBi for 1700MHz  and 8.51 dBi for 1900MHz. Under no 
conditions may an antenna gain be used that would exceed the ERP and EIRP power limits as specified in FCC Parts 22H, 24E and 27, or ISED RSS-130, 
RSS-132, RSS-133, and RSS-139. 

 

 

Support and Warranty

 

For online support information, please go to: https://mywebtech.honeywell.com/ 

For the latest warranty information, go to: 
www.honeywell.com/security/hsc/resources/wa 

For patent information, see www.honeywell.com/patents 

 

MyWebTech 

 

Warranty 

 

Patents 

 
 

 

 

Ê800-23340mŠ

 

800-23340  10/17  Rev B 

 

2 Corporate Center Drive, Suite 100,  

P.O. Box 9040, Melville, NY  11747 

 2017 Honeywell International Inc.

 

www.honeywell.com/security

 

 

Содержание LTE-X series

Страница 1: ... X S Se er ri ie es s C Co om mm mu un ni ic ca at to or rs s L LT TE E X XV V L LT TE E X XA A L LT TE E X XC C I In ns st ta al ll la at ti io on n a an nd d S Se et tu up p G Gu ui id de e 800 23340 10 17 Rev B ...

Страница 2: ...Programming Tool 6 Programming Conventions 7 Using the Control Panel 7 Programming 7 Programming Options 7 ECP Status Codes 10 Exiting the Programming Mode 10 Setting Factory Defaults 11 Registering the Communicator 11 Registering through the AlarmNet 360 Website 11 Remote Services Total Connect 12 Registering Using the Test Message Registration Switch 12 Registering Using the 7720P Programming To...

Страница 3: ...antennas provide additional security Simple programming using the 7720P programming tool or via the AlarmNet 360 website Uses 2 way ECP communication with the control panel Sends reports in Contact ID format Supports remote control of alarm system via Remote Services feature Allows uploading and downloading of control panel data Fully powered primary and backup battery from the control panel The L...

Страница 4: ...h for Certificate number 979 Remote Services Features UL Remote Access has not been evaluated by UL Honeywell offers secure web based services that enable users to remotely monitor and control their security system These web services enable users to Monitor and control their security system from a website Receive e mail and text message notifications of system events Control the system and receive...

Страница 5: ...lowing procedure assumes the control panel will be used for power If satisfactory signal strength is present at the control panel that is the preferred mounting location 1 Ensure power to the control panel both AC and battery is off Open the enclosure and connect the ECP cable connector to the communicator Connect the cable wires to the control s ECP terminals 2 Turn power on and wait for the comm...

Страница 6: ...le to the communicator circuit board and thread the wires through the threaded mounting adapter 5 Refer to the control panel s installation guide and complete the ECP cable wiring 6 Secure the wiring with ties as necessary Mounting the Module on the Wall 1 Ensure control panel power both AC and battery is off then remove a suitable knockout on the top or side of the control panel cabinet NOTES If ...

Страница 7: ... wiring to the control panel A control panel knockout that is presently used can be utilized however DO NOT utilize a control panel knockout that is being used for primary power 6 Refer to the installation guide for the control panel and complete the ECP cable wiring 7 Secure the wiring with ties as necessary Programming the Module The LTE X requires an AlarmNet account For new installations pleas...

Страница 8: ...y To perform a Shift function press the shift key then press the appropriate key The following table lists each normal and shift key function 7720P Normal and Shift Key shift LED lit Functions KEY NORMAL KEY FUNCTION SHIFT KEY FUNCTION BS ESC BS Press to delete entry ESC Press to quit program mode also can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO ...

Страница 9: ...e communicator interface on ECP so be sure to check the control panel s Installation and Setup Guide to see if it supports this feature Press the ENTER key to begin programming NOTE The central station can remotely block access to local device programming If this has been done prompt on the right appears Access to Prog Mode Denied The default programming values for each prompt are shown in parenth...

Страница 10: ...ompt 3 Press ESC to load factory defaults Refer to the Exiting the Programming Mode topic 9 Multi Mode Disabled _ Disabled Enhanced Reports Disable for normal alarm processing and go to Prompt 11 Primary City ID prompt Select Enhanced Reports if you want system events sent by e mail to the user Enhanced Reports enables reporting to Total Connect 2 0 web services NOTE To use Enhanced Reports ensure...

Страница 11: ... AlarmNet 360 website 17 Keypad Address 28 _ 01 30 NOTE This prompt will only appear if the Remote Access feature has been enabled Must be programmed if using the Remote Access feature Enter the appropriate device address 18 Supervision 24 Hours _ 30 Day 24 Hour None The AlarmNet network must hear at least one supervisory message from the communicator during this supervision period otherwise Alarm...

Страница 12: ...will display a fault message if any of the events listed below occur Module lost communications with the control panel Module lost contact with AlarmNet Module is not registered account not activated Module shutdown In addition the Contact ID codes for some of these conditions are reported by the control panel and sent by AlarmNet to the central station Exiting the Programming Mode To exit the pro...

Страница 13: ...gistration successfully completes the communicator enters a normal operating mode the REG green LED goes out and the TX RX yellow LED is lit to indicate that the power on reset message is waiting to be sent This message will appear at the receiving station as E339 803 The description may read Trouble Exp Mod Reset If registration is not validated within 90 seconds the communicator times out and th...

Страница 14: ...communicators Enhanced Reports must be enabled Once the dealer assigns a login name and password the customer will receive a Welcome e mail message with their login name along with some helpful information The customer will receive another e mail message with their password They will then be able to receive notifications and access their system via the Total Connect website or using their cell pho...

Страница 15: ... or an error was made in programming the Primary account information of the communicator for an existing account This prompt appears for 2 seconds See the Replacing an existing communicator topic Replacing an existing communicator Enter PIN This prompt appears after pressing the down arrow on the 7720P Enter a 4 digit alphanumeric PIN number provided by your central station your dealer or an autho...

Страница 16: ...he box and inside the communicator Press the Space key to go to the next field Press the BS key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this device Press the Space key to go to the next field Press the BS key to go to the previous field IMEI xxxxxxxx xxxxxx x IMEI Display Displays the identification n...

Страница 17: ...to 12dB 4 stars 13dB to 14dB 3 stars 15dB to 16dB 2 stars 17dB and lower 1 star Press the space key to go to the next screen Press the backspace key to go to the last screen LTE Displays RRAT RSRP RSRQ LTE xxxx xxxx Signal Display for LTE RAT Radio Access Technology RSRP Reference Signal Received Power RSRQ Reference Signal Received Quality Press the space key to get to the next screen Press the b...

Страница 18: ... space key to get to the next screen Press the backspace key to go to the previous field RSCP MIN MAX xxxx xxxx xxxx Min Max Signal Display for LTE RSRP Current Reference Signal Received Power MIN Minimum Receive Signal Level MAX Maximum Receive Signal Level Press the space key to get to the next screen Press the backspace key to go to the previous field Cntry Netw LAC xxx xxx xxxxx Location Displ...

Страница 19: ...ode Pressing Y resets the device Shift UP arrow Registering Registration Registers a programmed communicator with AlarmNet DN arrow Enter PIN Registration with PIN for Replacement Module Registers a replacement communicator with AlarmNet once programmed using the existing PIN 0 Force Server Update Y N Force Upload of Configuration File to Server Pressing Y will force the device to upload its entir...

Страница 20: ...ware update Fail E366 Glossary 4G LTE Refers to the fourth generation Long Term Evolution cellular wireless standards AES Advanced Encryption Standard CRC Cyclic Redundancy Check used to confirm validity of MAC ID ECP Enhanced Console Protocol is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices It uses four wires power ground data in data out IM...

Страница 21: ...LTE X Series Installation and Setup Guide 19 NOTES ...

Страница 22: ...LTE X Series Installation and Setup Guide 20 NOTES ...

Страница 23: ...ending QUICK PERIODIC BLINK Normal FAST BLINK Message waiting for network ACK SLOW BLINK In unison with green LED Registration in progress FAULT red ON No contact with network OFF Normal SLOW BLINK Loss of communication with the panel ECP fault FAST BLINK No network contact AND loss of communication with the control panel SIGNAL green ON Minimum required signal strength is present OFF Installation...

Страница 24: ...mful interference and 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d ISED Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interférences nuisibles 2 Cet appareil doit accepter toute interférence reçue y com...

Отзывы: