TouchPRO Wireless
™
P/N 041-338 Rev. A
9
69-2655EFS—01
Setup functions
Settings & Options
(factory default in
bold
)
Installer setup
Continued on next page
0360
HP Aux Lockout
40 40 ºF 4.5 ºC
0 None
5 5 ºF -15.0 ºC
10 10 ºF -12.0 ºC
15 15 ºF -9.5 ºC
20 20 ºF -6.5 ºC
25 25 ºF -4.0 ºC
30 30 ºF -1.0 ºC
35 35 ºF 1.5 ºC
45 45 ºF 7.0 ºC
50 50 ºF 10.0 ºC
55 55 ºF 13.0 ºC
60 60 ºF 15.5 ºC
65 65 ºF 18.5 ºC
0500
Furnace Filter 1
Change Reminder
0 Disabled
1 10 R.T. Day
2 30 R.T. Day
3 60 R.T. Day
4 90 R.T. Day
5 120 R.T. Day
6 180 R.T. Day
7 270 R.T. Day
8 365 R.T. Day
9 30 C Days
10 60 C Days
11 90 C Days
12 120 C Days
13 180 C Days
14 365 C Days
0502
Furnace filter
reminder run time
equipment counts
0 Counts heat and cool
1 Counts cool only
0510
Humidifier Pad
Replacement
Reminder
0 Disabled
1 90 C Days, 30 R.T. Days
2 180 C Days, 60 R.T. Days
3 365 C Days, 90R.T. Days
0520
UV Lamp
Replacement
Reminder
0 Disabled
1 365 Days
2 730 Days (2 years)
0580
Compressor
protection
5 5 minute compressor OFF time
[Other options: 0, 1, 2, 3 or 4-minute off time]
0640
Clock format
12 12-hour time (i.e., “3:30 pm”)
24 24-hour time (i.e., “15:30”)
0650
Extended fan
timer (heat)
0 OFF
90 Fan runs for 90 seconds after call for heat ends
0660
Extended fan
timer (cool)
0 OFF
90 Fan runs for 90 seconds after call for cooling ends
0670
Keypad lock
0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked