Honeywell L91A Скачать руководство пользователя страница 10

L91A,B,D PROPORTIONING PRESSURETROL

®

 CONTROLLERS

60-2152—08

10

Fig. 8. Removing terminal block bracket.

Fig. 9. Replacing potentiometer in L91.

Fig. 10. Replacing terminal block bracket.

DIFF.

MAIN

MIN

B

D

F

E

C

A

0

4

6

2
1

3

4

5

16
14
12
10

8

0

kPa

 OZS

  IN

2

DIFF. IS

ADDITIVE

2

6

7

M8521A

REMOVE BRACKET SCREW

FROM TOP OF CASE

TERMINAL 

BLOCK 

BRACKET

TERMINAL

BLOCK

DIFF.

MAIN

MIN

B

D

F

E

C

A

0

4

6

2
1

3

4

5

16
14
12
10

8

0

kPa

 OZS

  IN

2

DIFF. IS

ADDITIVE

2

6

7

M8547A

BARE WIRES

(ENAMEL REMOVED)

TERMINAL

BLOCK

R

W

B

POTENTIOMETER WIRES

WIPER ARM

BOLT

POTENTIOMETER

ACTIVE WINDING

POTENTIOMETER 

BRACKET

1

1

2

2

THE POTENTIOMETER IN AN L91A IS MOUNTED AT A 45 DEGREE

ANGLE INSTEAD OF HORIZONTALLY. AN L91D HAS TWO 

POTENTIOMETERS.

TERMINALS ARE LABELED.

DIFF.

MAIN

MIN

B

D

F

E

C

A

0

4

6

2
1

3

4

5

16
14
12
10

8

0

kPa

 OZS

  IN

2

DIFF. IS

ADDITIVE

2

6

7

M8548A

TERMINAL

BLOCK

TERMINAL

BLOCK

BRACKET

R

W

B

FIT HOLE IN BOTTOM

OF BRACKET OVER SCREW

PROTRUDING UPWARD

FROM BOTTOM OF CASE

Содержание L91A

Страница 1: ...iphon loop is recommended Wiper on controller potentiometer moves in response to pressure changes L91D has two potentiometers for unison control of two motors L91B D models have adjustable proportioning throttling range to allow selection of desired pressure control range Adjustments made with screws on case top Large easily read scaleplates in both U S customary oz sq in psi or in Hg and metric k...

Страница 2: ...rled knob for main scale setting on 10 to 300 psi 0 07 to 2 07 MPa models Setpoint At low pressure end of proportioning throttling range Main Scaleplate Marked in both U S customary oz sq in psi or in Hg and metric kPa MPa or mm Hg units Proportioning Range Scaleplate L91B D only Gradu ated from A to F with a MIN minimum value below A See Table 2 for the value of each division Mounting Means Fitti...

Страница 3: ...6 Steam Trap siphon loop 1 4 in steel pipe with 1 4 18 NPT external threads on both ends 33312B Knurled Adjustment Knob With setscrew fits on main scale pressure adjusting screw 4074BWJ Limit Stop Assembly To limit setpoint ranges includes 129564 Range Stop 107194 Range Stop Screw and 23466 Wrench Table 2 Approximate value of each division A to B B to C etc on proportioning throttling range scalep...

Страница 4: ...RE ALSO AVAILABLE WITH 1 4 19 BSP TR INTERNAL THREADS SEE TABLE 1 PROPORTIONING RANGE ADJUSTING SCREW ON L91B D MODELS ONLY 33312B KNURLED ADJUSTMENT SCREW KNOB 7 8 IN 22 2 MM DIAMETER KNOB IS INCLUDED WITH 10 TO 300 PSI 0 07 TO 07 MPa MODELS OPTIONAL ACCESSORY FOR OTHER MODELS FOR 10 TO 300 PSI 0 07 TO 2 07 MPa MODELS DIM C INCLUDES THE KNURLED ADJUSTMENT KNOB TABULATION OF DIMENSIONS A B AND C O...

Страница 5: ...ns in accordance with approved standards Use only a small amount of pipe compound to seal the connection joints Excess pipe compound may clog the small hole in the fitting and prevent the controller from operating properly To avoid leaks and damage to the case use a parallel jaw wrench on the controller fitting Do not tighten the controller by hand by holding onto the case and turning it Fig 2 App...

Страница 6: ...ain Scale Set Point All models Adjust the main scale setpoint for the desired operating pressure by turning the main scale adjusting screw Fig 7 or knurled adjustment knob on 10 to 300 psi 0 07 to 2 07 MPa models on the top of the case until the main scale setting indicator is at the minimum pressure desired The proportioning range extends above this value The scaleplate is marked in both customar...

Страница 7: ...nced that is equal the relay contacts are open When the circuit is balanced the motor or actuator does not run If the pressure of the medium rises the wiper in the controller moves toward W This unbalances the circuit so a larger current flows through one side of the balancing relay The close contacts in the relay make causing the motor or valve actuator to drive toward its closed position As the ...

Страница 8: ...e controller The ohmmeter should read about 135 ohms for an L91A B or D 5 Connecting the ohmmeter between controller terminals W and R Fig 8 and raising the setpoint of the controller above the actual pressure being measured The ohmme ter should read the full value of the potentiometer mea sured in step 4 135 ohms for an L91A B or D 6 Slowly lowering the setpoint of the controller while observing ...

Страница 9: ... the wiper arm and not to change the wiper tension Any damage or change in tension will decrease the life of the new potentiometer 1 Disconnect all power to the controller 2 Loosen the cover screw below the main scaleplate and remove the cover 3 Mark the wires to the external device motor or valve actuator and disconnect them from the terminal block 4 Remove the screw holding the terminal block br...

Страница 10: ...A 0 4 6 2 1 3 4 5 16 14 12 10 8 0 kPa OZS IN 2 DIFF IS ADDITIVE 2 6 7 M8547A BARE WIRES ENAMEL REMOVED TERMINAL BLOCK R W B POTENTIOMETER WIRES WIPER ARM BOLT POTENTIOMETER ACTIVE WINDING POTENTIOMETER BRACKET 1 1 2 2 THE POTENTIOMETER IN AN L91A IS MOUNTED AT A 45 DEGREE ANGLE INSTEAD OF HORIZONTALLY AN L91D HAS TWO POTENTIOMETERS TERMINALS ARE LABELED DIFF MAIN MIN B D F E C A 0 4 6 2 1 3 4 5 16...

Страница 11: ...L91A B D PROPORTIONING PRESSURETROL CONTROLLERS 11 60 2152 08 ...

Страница 12: ...ons Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2009 Honeywell International Inc 60 2152 08 K K Rev 12 09 Printed in U S A ...

Отзывы: