L4064B, L4064R UNIVERSAL COMBINATION FAN AND LIMIT CONTROLLERS

Home and Building Technologies

In the U.S.:

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422-3992

customer.honeywell.com

® U.S. Registered Trademark
© 2017 Honeywell International Inc.
69-0115—11    M.S.  Rev. 06-17
Printed in United States

3.

Push male flag connector directly into the 
female receptacle. Make sure that the flag is 
forced to the bottom of cavity and wire is in the 
channel (Fig. 5).

Fig. 5.  Location of Wiring Connections.

Fan Setting Adjustment

1.

Move the FAN OFF lever to the temperature at 
which the fan is to stop to prevent circulation of 
cool air.

2.

Move the FAN ON lever to the temperature at 
which the fan is to turn ON to circulate warm air.

Manual Fan Switch

For constant fan operation (overriding fan setting 
levers), push the FAN switch button in. For fan to 
cycle automatically, pull button out.

Limit Setting Adjustment

Move the limit lever to the temperature at which the 
high-limit switch will open to stop the burner.

CHECKOUT

When installation is complete, disconnect the fan 
motor circuit at the L4064. Turn on power and set 
thermostat to call for heat. Burner should come on 
and limit controller should shut burner off when 
plenum temperature reaches the limit set point. Turn 
off power, reconnect the fan switch, turn on power 
and again set thermostat to call for heat. The fan 
should start when plenum temperature has reached 
fan-on setting.

Fig. 6. L4064 Dimensions.

M33953

STRIP GAUGE

PUSH MAN

PULL AUTO

LEADWIRE

WITH 1/4 IN.

[6.4mm]

FEMALE SPADE

TERMINAL

(FORCE SPADE

TO BOTTOM

OF CAVITY)

FEMALE

RECEPTACLE

FOR CONNEC-

TION OF 1/4 IN. 

[6.4mm]

MALE SPADE

TERMINAL (4)

STANDARD

WIRE TO 

CONTROLLED

EQUIPMENT

TO RELEASE

STANDARD

WIRE, PUSH

SCREWDRIVER

IN AND PULL

WIRE OUT

WIRING GUARD

REMOVABLE

BRASS

JUMPER

STANDARD

WIRE PUSH-IN

CONNECTORS

(4)

LIMIT

FAN

CAUTION

DO NOT ROTATE  --  HOLD

DIAL WHEN SETTING POINTERS

150

100

200

LIMIT

OFF

OFF

ON

FA

N

250

50

M34064

2-3/8 (60)

1-29/32

(48)

5/16 (8)

4-9/32

(109)

DIM. A

1-1/32

(26)

3/4

(19)

STANDARD

1/2 (13)

3-23/32

(95)

3-1/4

(83)

3 (76)

1-3/16

(30)

1-3/16 

(30)

5X 7/32

(6)

NOTE:  OVERALL DEPTH WITH FAN SWITCH IS 2 IN. (51 MM) ON ALL MODELS.

1-19/32

(40)

2X 7/16 (12)

11-1/2

8

5

INSERTION

[NOMINAL]

DIM. A

INCH

(MM)

INCH

(MM)

(292)

(203)

(127)

11-5/8

8-1/8

5-1/8

(295)

(206)

(130)

3X 11/32 (9)

Содержание L4064R

Страница 1: ...N OFF setting is reached If the call for heat continues until the temperature in the plenum rises to the LIMIT setting the bimetal element will mechanically break the limit contacts and de energize the heating control circuit INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to fol low them could damage the product or cause a hazardous condition 2 Check the rati...

Страница 2: ... 20 6 mm hole Surface Mounting Fig 1 L4064B Hole in plenum should be just large enough to accommodate the 3 4 in 19 1 mm diameter element tube A 13 16 in 20 6 mm diameter hole is recommended 1 Remove cover by removing screw squeezing sides and pulling off Insert element in plenum and mark location of mounting holes Make sure the case is snug against the plenum before marking the mounting holes 2 P...

Страница 3: ...Fig 5 For Standard wire Push in terminals Connect wires to the terminals as follows 1 Use Nos 14 16 or 18 solid wire or Nos 14 or 16 stranded wire depending on electrical require ment 2 Strip insulation from wires the distance shown by the strip gauge on the controller If wire insu lation is 4 64 in 2 mm thick strip additional 1 4 in 6 mm to ensure wire seats securely in push in connectors 3 Solid...

Страница 4: ...n is complete disconnect the fan motor circuit at the L4064 Turn on power and set thermostat to call for heat Burner should come on and limit controller should shut burner off when plenum temperature reaches the limit set point Turn off power reconnect the fan switch turn on power and again set thermostat to call for heat The fan should start when plenum temperature has reached fan on setting Fig ...