HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM
95-7767
38
NOTE:
1.
Frame-Ground should always be the first signal to connect to and last signal to disconnect from the system.
2.
Pulled-up to high level internally.
2
DO-1-GND
Digital Output 1 Ground
Connector J12
1
RL-0-Com
Relay 0 Dry Contact Common
2
RL-0-NO
Relay 0 Dry Contact Normal Open
3
RL-0-NC
Relay 0 Dry Contact Normal Close
Connector J13
1
RL-1-Com
Relay 1 Dry Contact Common
2
RL-1-NO
Relay 1 Dry Contact Normal Open
3
RL-1-NC
Relay 1 Dry Contact Normal Close
Connector J14
1
RS485-A
RS485 bus A (non-inverting signal) signal
2
RS485-B
RS485 bus B (inverting signal) signal
3
RS485-GND
RS485 bus Ground
Connector J17
1
InterLock-0
Interlock Input 0 (Relay 0 bypass activation)
2
InterLock-0-GND
Interlock 0 Ground
Connector J18
1
InterLock-1
Interlock Input 1 (Relay 1 bypass activation)
2
InterLock-1-GND
Interlock 1 Ground
1
12V DC Power
12VDC Power Input, tolerate up to 28VDC
Connector
Signal Description