![Honeywell HW1000i - Portable Inverter Generator Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/honeywell/hw1000i-portable-inverter-generator/hw1000i-portable-inverter-generator_owners-manual_151459032.webp)
Transporting Generator
26
www.honeywellgenerators.com
HW1000i / HW2000i Inverter Generator Owner’s Manual
Transporting Generator
Transporting Generator
When transporting the generator:
1.
Press the engine control switch to the STOP position.
2.
Turn the fuel valve to the OFF position.
3.
Turn the fuel cap vent to the OFF position (HW1000i
model only).
4.
Keep the generator level to prevent fuel spillage.
Storing Generator
Before storing the generator for extended period of time:
•
Be sure storage area is free of excessive humidity
and dust.
•
Refer to Table 8 for recommended preparation proce-
dures.
To prepare the generator for long-term storage:
.
1.
Drain fuel into suitable container (see page 27).
2.
Change engine oil (see page 19).
3.
Remove spark plug (see page 25).
4.
Add a tablespoon of clean engine oil into spark plug
hole.
5.
Place rag over spark plug hole and pull recoil starter
handle slowly to turn engine and distribute oil.
6.
Reinstall spark plug.
• Hot engine or exhaust system can cause seri-
ous burns or fires. Cool generator completely
before transporting or storing.
• Do not leave generator inside vehicle during
high temperatures. This could cause the fuel to
vaporize and possibly explode.
• Do not overfill the tank before transporting.
• Do not drive across rough terrain while trans-
porting the generator as this may cause fuel
leakage. Drain fuel from generator.
• Do not operate generator while it is in a vehicle.
NOTICE
NEVER drop, strike, or place heavy objects on generator
when transporting.
WARNING
NOTICE
Follow service procedures for preparing generator for stor-
age. Inadequate or improper care of generator can result in
damage to generator components and will void limited war-
ranty.
Storage Time
Recommended Preparation
Less than 1
month
No preparation required.
1 to 2 months
Fill fuel tank with fresh gasoline and
add gasoline conditioner
*
.
*
Use gasoline conditioners formulated to extend storage life.
Contact authorized generator dealer for conditioner recommen-
dations.
More than 2
months
See procedure below.
TABLE 8. Recommended Service Procedures Based on Storage
Time
Fuel and its vapors are extremely flammable and
explosive under certain conditions.
•
NEVER smoke or allow flames or sparks near generator
or where gasoline is stored.
DANGER