VISTA Series HSD Speed Dome 

 

 

 

Read this Manual carefully before installation and keep it by hand for future reference. 

 
 
 
 
 

Содержание HSD-361P

Страница 1: ...HSD 361P Operation Manual VISTA Series HSD Speed Dome Read this Manual carefully before installation and keep it by hand for future reference ...

Страница 2: ...mage to the product Please do not remove or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera Please connect all the wires of the dome strictly accordingly to the specifications It is highly recommended that the proper lightning arrestors and surge suppressors are installed before the dome is...

Страница 3: ...iring Specifications 8 Camera Exposure 21 Chapter Three Basic Configuration 9 Mask Zone 22 3 1 Wiring 9 Mask Color 22 3 2 Protocol and baud rate setting 10 Others 23 3 3 Address setting of each dome 11 4 7 Function Programming 22 3 4 Controller setting 11 PTZ Tour 22 Chapter Four Menu setting 12 Program Vector Scan 23 4 1 Operation instruction 12 Annex Short cut operations and specification Main M...

Страница 4: ...arton Description Qty Manual Certificate each1 BNC Wire 1 Rubber Cushion 1 Lower housing of dome 1 Bag of screws 1 High Speed Dome 1 Camera Module 1 Wall bracket 1 AC24V transformer 1 Camera Shroud 1 Terminal 2 Please contact the distributors in time if the spare parts are missing 1 ...

Страница 5: ...The camera title is user definable as well as the ability to display or not the camera coordinates On screen Crosshair function By enabling this option the target can be followed more effectively using the crosshairs as a reference point Three users define PTZ tours with up to 2 minutes record duration for each tour User has the ability in real time to monitor and record the action of a manual dom...

Страница 6: ...eo camera to avoid normal operation and possibly void the warranty 2 1 5 During usage user should abide by all electrical safety standards Use only the power supply specified by manufacturer The control cable for RS485 communications as well as the video signal cables should be isolated from high voltage equipment and or high voltage cables It is highly recommended that the proper lightning arrest...

Страница 7: ...on top half Figure 2 Illustrates the lower layer of the carton bottom half Fig 1 Fig 2 Sequence No Description 1 Manual Certificate 2 BNC Wire 3 Rubber Cushion 4 Lower housing for the dome Terminal 5 Bag of Screws 6 High Speed Dome 7 Camera Module 8 Wall bracket 9 AC24V transformer 10 Camera Shroud 3 2 3 4 5 6 7 8 1 9 10 ...

Страница 8: ...rtical axis tray of the dome as illustrated in Fig 6 and Fig 7 Attention Take care not to scratch the lens when installing the camera Do make sure the camera model is the right one for installation Secure the camera to the corresponding screw holes as illustrated in Fig 6 according to the model and make of the camera as different camera models may have different dimensions Following the installati...

Страница 9: ...he core of the dome as illustrated in Fig 10 2 4 2 Utilizing the supplied 4 four M3 14 screws securely tighten the camera shroud in place as illustrated in Fig 11 2 5 Bracket installation 2 5 1 Feed the BNC wiring harness through the channel inside the wall bracket as illustrated in Fig 12 Verify that the channel remains empty before feeding the wiring harness Feed the BNC Wiring from here 4 M6 ex...

Страница 10: ...racket Fig 15 illustrates installation of pendent bracket 4 M 8 S i l i c a g e l S i l i c a g e l B r a c k e t a d a p t e r W al l bracket Fig 14 Fig 15 Fig 16 illustrates installation of pole bracket 4 M 8 4 M 8 S i l i c a g e l Fig 16 6 ...

Страница 11: ...ve so as to prevent any abrasions or scratches to the surface as this will affect the optical performance of the camera Installation instruction 1 Carefully align the two parts and slowly rotate counterclockwise as illustrated in Fig 17 2 Remove the protection film as illustrated in Fig 18 Fig 17 Align the two parts and rotate clockwise as indicated Remove the protection film Fig 18 7 ...

Страница 12: ... supply 图19 黄绿相间 接大地 视频输出 黑色 红色 A C 2 4 V 电源 黄色 R S 4 8 5 橙色 R S 4 8 5 黄绿相间 接大地 接控制键盘 BNC Connector Video output Orange RS485 Yellow RS485 Red black AC24V power supply Terminal Connect to the dome device Yellow green Ground wire Connect to keyboard controller Yellow green Ground wire Fig 19 AC 24V Power Supply Connect 220V power supply Connect to dome Fig 20 8 ...

Страница 13: ...nts Yellow green Ground wire BNC Connector Video output Orange RS485 Yellow RS485 Red black AC24V power supply Terminal Connect to the dome device Yellow green Ground wire Connect to keyboard controller Caution This operation should be performed with the power OFF Yellow green Ground wire BNC Connector Video output Orange RS485 Yellow RS485 Red black AC24V power supply Terminal Connect to the dome...

Страница 14: ...ud rate should be set to correspond with the chosen control system 3 2 Protocol and baud rate setting Caution This operation should be performed with the power OFF ON 1 2 3 4 5 6 Protocol and baud rate On Off Protocol setting Baud rate setting On Off Protocol type 1st 2nd 3rd 4th 5th 6th PELCO D ON ON OFF OFF PELCO P OFF OFF ON OFF Auto Detect OFF OFF OFF OFF Kd6 ON ON ON ON VCL OFF OFF ON ON Max ...

Страница 15: ...the protocol of keyboard controller can be set PELCO D or PELCO P arbitrarily But its baud rate should be set identical with that of the dome device When all of the above settings are completed you can start testing to dome functionality Up Right Left joystick Down Zoom in Zoom out Rotating joystick 11 The operation of the dome and the direction up down left controlled using and right of the camer...

Страница 16: ...and setup the PreShot position on the menu uration menu for the dome 1 n to enter the main 2 or Down direction Select 90 on the preset positio configuration menu for the dome To make a selection move the joystick in the Up The on screen arrow points to the selected option Press OPEN or move the joystick Left or Right you can enter the submenu f HSD or the selected option or change the value of you...

Страница 17: ... Still OFF IRIS CLOSE to Exit Camera Options Function Menu C 1 Clear Memory 2 Restore Def Setting 3 Color System PAL e Information Camera Options 4 3 Displ PreShot N r Name 5 Mas IRIS CLOSE to Exit 1 Camera Exposure 2 Camera 3 Others 4 Mask Zone k Color There are two methods to set up the PreShot Position 1 Setup and c Function Programming 2 Program IRIS CLOSE to Exit 1 PTZ Tour Vector Scan PreSho...

Страница 18: ... the menu 1 Edit the number to be deleted Refer to Number Input Instruction Note Select the PreShot to be deleted 2 Move the cursor to select the Deleted Position 4 Move the joystick Left or Right to enter the deleting position 5 Press OPEN when done Press CLOSE to exit Are you sure to do this IRIS OPEN to Confirm IRIS CLOSE to Cancel PreShot Name 1 Number 1 7 Move the joystick Left or Right or pr...

Страница 19: ...hen Done PreShot Name 6 Name Display Off IRIS CLOSE to Exit On Off Setting on the PreShot Name 1 Move the cursor to select Name Display 2 Move Left or Right or press OPEN to enter On Off Name Display 0 3 6 3 0 1 2 3 4 5 6 7 8 9_ IRIS CLOSE When Done Sector Setup 1 Number 1 2 Name 3 Pan Start POS 0 0 4 Pan End POS 0 0 5 Tilt Start POS 0 0 IRIS CLOSE to Exit 1 Move the joystick Up or Down to move th...

Страница 20: ...OSE to Exit 1 Select Pan Start POS Press OPEN to enter 2 Move the joystick Left or Right to move the dome Press CLOSE when done Now the camera is on Pan Start Position Sector Setup 1 Number 1 2 Name 3 Pan Start POS 262 0 4 Pan End POS 0 0 5 Tilt Start POS 0 0 IRIS CLOSE to Exit Setup Pan End Tilt Start Tilt End according to the above instruction Sector Setup 1 Number 1 2 Name 3 Pan Start POS 262 0...

Страница 21: ...tions 1 Preset Position 2 Sector Setup 3 Coordinates On 4 Crosshair Off 5 Start UP Scr Msg On IRIS CLOSE to Exit Steps Move the cursor to select Coordinates or Crosshair or Start UP Scr Msg Move joystick Left or Right or press OPEN to switch On Off Control Options 1 Set Pan and Tilt 2 Set Default Function 3 Speed Limit On 4 Auto Flip On 5 Auto Focus PTZ 6 Auto AE PTZ 7 Vector Scan AF Off 8 Vector ...

Страница 22: ...s 1 Clear Memory 2 Restore Def Setting 3 Color System PAL 4 Dome Information IRIS CLOSE to Exit Function Clear all memory but can not clear function of dome Steps Move the joystick Up or Down to move the cursor to select Clear Memory Move the joystick Left or Right or press OPEN to enter Press OPEN to reconfirm Press CLOSE to cancel it and return Diagnostic Options 1 Clear Memory 2 Restore Def Set...

Страница 23: ...ge English 2 Display Options 3 Control Options 4 Diagnostic Options 5 Camera Options 6 Function Programming IRIS CLOSE to Exit Function User can setup the functions of the camera accordingly Steps 1 Move the joystick Up or Down to move selection Camera Options 2 Move the joystick Left or Right to press OPEN to enter Camera Options 1 Camera Exposure 2 Camera Name 3 Others 4 Mask Zone 5 Mask Color R...

Страница 24: ...Level Auto IRIS CLOSE to Exit AE Control 1 AE Mode Auto 2 Shutter Speed Auto 3 Iris Level Auto 4 AGC Level Auto IRIS CLOSE to Exit AE Control 1 AE Mode Auto 2 Shutter Speed Auto 3 Iris Level Auto 4 AGC Level Auto IRIS CLOSE to Exit AE Control 1 AE Mode Auto 2 Shutter Speed Auto 3 Iris Level Auto 4 AGC Level Auto IRIS CLOSE to Exit 1 AE Mode Steps 1 Move the joystick Up or Down to move the cursor t...

Страница 25: ... mask zone 1 24 2 Mask Zone 1 Move the joystick Up or Down to move the cursor to select Mask Zone 2 Move the joystick Left or Right or press OPEN enter and program Camera Options 1 Camera Exposure 2 Camera Name 3 Others 4 Mask Zone 5 Mask Color Red IRIS CLOSE to Exit Mask Zone 1 Number 1 2 Mask Edit 3 Mask Display Off IRIS CLOSE to Exit Mask Zone 3 Press CLOSE when done 1 Number 1 2 Mask Edit 3 Ma...

Страница 26: ...r to select PTZ Tour Function Programming 2 Move the joystick Left or Right or press OPEN to enter 1 PTZ Tour 3 Move the joystick Up or Down to select desired operating or programming PTZ 2 Vector Scan Tour Number 4 Move the joystick to move the cursor to select Name IRIS CLOSE to Exit 6 Move the joystick Up or Down to move the cursor to select PTZ Tour PTZ Tour 7 Press OPEN to enter Manual Operat...

Страница 27: ...rogram a Vector Scan 1 Name P is the sign of PreShot Position 3 Run a Vector Scan V is the sign of Vector Scan 4 Delete a Vector Scan T is the sign of PTZ Tour IRIS CLOSE to Exit 2 Number Select the function based on name 3 Speed Setup the speed to meet the PreShot 4 Dwell Time Setup Dwell Time when PreShot and PTZ Tour done Run Vector Scan Operation 1 Select the Vector Scan Tour to be operated on...

Страница 28: ...l and baud rate as well as dome device address There is character display in normal circumstance 6 Cannot stop pan rotation rotate and stop alternatively OSD board is not properly connected with main control board or the photoelectric switch is broken Pan interrupt is not in due position fix OSD board again if the problem still exits then replace the OSD board Adjust the pan interrupt Pan interrup...

Страница 29: ...PRESET 63 one Push WB CALL Set short way Line Scan PRESET 79 Set long way Line Scan CALL 80 Run first PTZ tour CALL 81 Run second PTZ tour CALL 82 Run third PTZ tour CALL 83 Run first Vector Scan CALL 84 Run second Vector Scan CALL 85 Run third Vector Scan CALL 86 Run fourth Vector Scan CALL 87 Run fifth Vector Scan CALL 88 Run sixth Vector Scan CALL Image Freeze On PRESET 89 Image Freeze Off CALL...

Страница 30: ...ocus Auto Manual Day Night Mode Auto ICR Color B W Video Output CVBS 1 0VP P 75 ohm BNC Privacy Zone Masking On Off 8 area Address 0 255 Zoom Focus PreShot 128 position PreShot PreShot accuracy 0 10 Speed of PreShot point 400 Second Pan speed range 360 Continue Tilt speed range 0 90 Manual speed pan 0 1 300 Sec Manual speed tilt 0 1 120 Sec PTZ Tour 3 Programmable Pan Tilt Zoom and each tour is 12...

Страница 31: ...e as you can In open area shield cables in steel tube and conduct a single point ground to the tube Trolley wire is forbidden in such circumstances In strong thunderstorm or high faradic zone such as high voltage transformer substation extra strong lightning arresters equipment must be installed Take the building lightning proof requirements into account to design the lightning arresters and groun...