Description of the parameters

Parameter 2 – Backlight

The display has a backlight for reading the information. 

• 

The backlight is ON when the adjustment dial is 
turned or a button is pressed. 

• 

The backlight switches OFF if no action is carried 
out at the radiator controller for approx. 7 seconds in 
order to save battery power.

Parameters 3 to 5 – Window function

In order to save energy the radiator controller closes the 
radiator valve when you open a window resulting in a 
large drop of the temperature. 
When you close the window so that the temperature 
rises the radiator controller opens the radiator valve 
again.
When the duration of the window function (factory 
setting: 30 minutes) has expired, the system controls 
to the current room setpoint temperature again. Frost 
protection is ensured during the window function.

Parameter 6 – Valve stroke

The radiator controller operates with the optimum valve 
stroke set in the factory.
If the entire valve stroke is to be used or if the valve does 
not open completely, activate the full-stroke mode.

Parameter 7 – Temperature representation in the 
display

• 

In the factory setting the room setpoint temperature 
is displayed.

• 

With the setting "measured temperature" the 
measured room temperature is displayed. A 
changeover to the set temperature is carried out by 
turning the adjustment dial or pressing the button. 
If required, the temperature can now be reset. The 
display returns to the measured temperature after 
approx. 3 seconds.  
Due to the heat influence of the radiator the 
"measured temperature" displayed at the radiator 
controller can differ from the temperature measured 
at another point in the room.

Parameter 8 – Temperature offset

Since the radiator controller measures the room 
temperature in the area of the radiator, it is possible 
that this temperature deviates from the temperature 
measured at a different point in the room.
If, for example, 20 °C is measured in the room and 
21.0 °C at the radiator, this effect can be compensated 
by an offset of –1.0 °C. 

Parameter 10 – Display of the valve position

When this parameter is activated (setting "1"), the 
calculated valve position (0 ... 100% opened) is 
displayed momentarily.
The main display is shown again after approx. 3 minutes. 
To cancel, select 

exit

 and press the 

 button. 

Parameter 11 – Window open function

• 

If a window contact is connected, the parameter is set 
automatically to "2" (cabled). The window function is 
controlled by the window contact.

• 

If no window contact is connected, the setting "0" or 
"1" has to be selected.

6. Further functions

Manual changing of the room setpoint
temperature

The room setpoint temperature can be changed at any 
time by means of the adjustment dial. The changed room 
setpoint temperature remains in effect until the next 
switching point.

The symbol 

 shows that the temperature was 

changed manually. The symbol extinguishes when the 
next setpoint is reached. 

By turning the adjustment dial anti-clockwise until 

off

 

is displayed, the valve will be closed permanently.
With this setting the time program of the central 
operating device is no longer active for this radiator 
controller, but frost protection is guaranteed if the 
heating is switched on.

Display of the room name

If the central operating device can transmit the room 
name (zone name), like the evotouch, the room 
name is displayed at the radiator controller (max. of 
9 characters).

 

f

Press 

 button.

The room name (zone name) is shown briefly in the 
display.

Содержание HR92

Страница 1: ...apters are available as accessories An external window contact can be connected optionally Energy saving features With the window function the radiator valve is closed when ventilating the room If an external window contact is used the radiator valve is closed when a window is open CAUTION f f Use the radiator controller only in accordance with these operating instructions f f Do not let children ...

Страница 2: ...splay Display Meaning signal 05 Field strength excellent signal 03 Field strength good signal 01 Field strength weak 4 Mounting Ready to operate in three steps Insert batteries and set language Establish radio connection Mount on radiator controller FINISHED Inserting changing batteries The radiator controller is set for the following battery type 2 alkaline cells 1 5 V type LR6 AA AM3 You can ins...

Страница 3: ...cuit batteries or throw them into fire f f Dispose of used batteries ecologically Establishing radio connection The radiator controller HR92 communicates with the central operating device by radio using the frequency of 868 MHz To this purpose the connection between the HR92 and the central operating device has to be established first This process is called BINDING In the case of preconfigured dev...

Страница 4: ...t a different mounting location for the room unit and repeat binding Clearing binding at the HR92 1 Press the button briefly 2 Hold the button pressed for 5 seconds 3 Select bind using the adjustment dial and keep the button pressed until cleared is displayed Binding is deactivated Radio test 1 Press the button briefly 2 Hold the button pressed for 5 seconds 3 Select rf check using the adjustment ...

Страница 5: ...dity and moisture f f Mount the radiator controller indoors only f f Protect the radiator controller against humidity moisture dust direct sunlight or exposure to excessive heat Removing the old thermostat head 1 2 1 Turn the old thermostat head counter clockwise until it stops and loosen the mounting ring 2 Remove the old thermostat head from the radiator valve Selecting the adapter The radiator ...

Страница 6: ...e radiator controller is in the open position 2 Put the radiator controller onto the valve baseplate so that the indentation latches in and is no longer visible 3 Lock the radiator controller in the end position To do so push the slide towards After approx 1 minute cycl self test is displayed Afterwards the radiator controller changes to normal operation 25 2 C i The radiator controller only opera...

Страница 7: ...ed to the HR92 radiator controller i The cable ACS90 is required to connect the external window contact Micro B mini plug open ends 2 m long Not included in the scope of delivery Operation with window contact When the window is opened the window contact is opened and the radiator valve closes When the window is closed again the radiator controller returns to normal operation The frost protection f...

Страница 8: ...tor controller and in the room Factory setting 0 Par Set ting Meaning 9 0 1 2 Battery type Alkaline Lithium NiMH accumulator chargeable 10 0 1 Display of the valve position No display of the valve position Momentary display of the valve position 11 0 1 2 Window open function Off no window function Auto corresponding to Parameters 3 5 Cabled with floating window contact 12 0 1 Restore to factory se...

Страница 9: ...measured at another point in the room Parameter 8 Temperature offset Since the radiator controller measures the room temperature in the area of the radiator it is possible that this temperature deviates from the temperature measured at a different point in the room If for example 20 C is measured in the room and 21 0 C at the radiator this effect can be compensated by an offset of 1 0 C Parameter ...

Страница 10: ...ing system from freezing up frost is displayed i The heating must be switched on to ensure the frost protection function 7 Help with problems Error table Problem Display Cause Remedy flashing Batteries flat Replace the batteries icons are flashing No radio com munication Check the radio connection between the HR92 and the central operating device radio test Repeat the binding procedure Check the p...

Страница 11: ...ation ISM 868 0 870 0 MHz RX Class 2 Range typically 30 m within residential buildings Supply voltage Battery type LR6 AA AM3 Alkaline 2 x 1 5 V Lithium 2 x 1 5 V NiMH 2 x 1 2 V Connection to the radiator M30 x 1 5 Ambient temperature 0 50 C Dimensions 96 x 54 x 60 mm Ambient conditions For living area business and commercial areas as well as small businesses Humidity 10 90 rel humidity 9 Disposal...

Страница 12: ...Switzerland by its Authorized Representative 11 Binding and radio test Overview Press the button briefly Display Room information Hold the button pressed for 5 seconds bind rf check exit button Hold the button pressed until button button binding cleared checking flashes back to standard display success button Radio signal from operating device back to standard display Display of the field strength...

Отзывы: