HM750A1000
17
33-00289—01
Fig. 26. Humidifier components.
HM750
Status
Service
Power
Idle
Filling
Humidifying
Draining
Cylinder
Fault
Drain
Fault Codes In Front Cover
M37211
STEAM
OUTLET
HIGH
WATER
SENSOR
USER
INTERFACE
POWER/DRAIN
BUTTON
FILL
VALVE
QUICK
CONNECTOR
DRAIN
OUTLET
DRAIN
VALVE
STEAM
CYLINDER
CYLINDER
PLUGS
FILL
CUP
Component
Function
Cylinder plugs
Power connectors to electrodes in cylinder.
Drain outlet
Connection to drain hose, used to remove water from the humidifier.
Drain valve
Drains water from humidifier.
Fill cup
Provides an air gap for backflow prevention.
Fill valve
Controls flow of water into humidifier.
High water sensor
Used to detect maximum water level in cylinder.
Power/Drain button
Used to turn the humidifier on or off. Note that before the humidifier turns off, the water in the
cylinder is drained.
CAUTION
The unit will still be powered internally even after being shut down.
Steam cylinder
Steam generating vessel that holds electrodes in water. Current between electrodes generates
heat used to generate steam.
Steam outlet
Connects to steam guide with short piece of steam hose.
Supply water
connection
Connection for supply water.
User interface