7.4.1.1 System
Alarm
Settings
1. From the System Alarms menu press the
1
button to enable/disable alarms and to
define the systems alarms as N.O.
(normally open) or N.C. (normally
closed)
a. Press
the
aux
button to change the
displayed settings. Use the joystick
up, down, left, or right to move
between the fields. When the field
you want to change is highlighted, press the
aux
button to toggle between the
available options for status and type. Use the number buttons to enter the alarm
priority.
Note
: If a priority of 0000 is entered and the user moves the joystick (or
presses lock), an error message is displayed for five seconds and then the
number reverts to its initial value before the number was changed. The cursor
remains on the amended number.
SYSTEM ALARMS SETTINGS
ALARM STATUS
TYPE
PRIORITY
01 DISABLED
N.O.
0001
02 DISABLED
N.O.
0002
03 DISABLED N.O. 0001
04 DISABLED N.O. 0001
05 DISABLED N.O. 0001
06 DISABLED
N.O.
0006
AUX TO CHANGE
LOCK TO EXIT
Note:
The down arrow to the right of the last alarm shown means there are
more lines below those displayed. If an operator moves down, an up arrow will
be displayed to the right of the first alarm to show there are more lines above
those displayed.
b. When finished programming alarms, press the
lock
button to exit the system
alarm settings menu and return to the Systems Alarm menu.
7.4.1.2 System Alarm Actions
SYSTEM ALARMS ACTIONS
ALARM CAMERA PRESET TIME RELAY
01 01
001 005 00-0
02 02
001
005 00-0
03 03
001 005 00-0
04 04
001 005 00-0
05 05
001 005 00-0
06 06
001 005 00-0
07 07
001 005 00-0
LOCK TO EXIT
To program the action the system is
to take when an alarm is activated,
access the Alarm Actions Menu.
1. From the System Alarms menu,
press the
2
button.
a. The camera for the first alarm
is flashing.
Use the joystick to move to
the desired field to change.
Note:
The down arrow to the right of the last alarm shown means there are
more lines below those displayed. If an operator moves down, an up arrow will
be displayed to the right of the first alarm to show there are more lines above
those displayed.
Rev. 1
36
900.0560
18-July-2005
Содержание HKJMMTP
Страница 1: ...HMAX082 HMAX162 Matrix Switcher HKJMMTP Keyboards Owner s Operation Guide 900 0560 July 2005 Rev 1 ...
Страница 2: ...ISSUE DATE REVISIONS 01 July 2005 Initial Release Rev 1 ii 900 0560 18 July 2005 ...
Страница 8: ...Notes Rev 1 viii 900 0560 18 July 2005 ...
Страница 115: ...Notes Rev 1 103 900 0560 18 July 2005 ...