HG1120 Installation and Interface Manual
|
aerospace.honeywell.com/HG1120
7
Table 2. Mode Selection
DIO4
DIO3
DIO2
DIO1
PROTOCOL
CONTROL/NAV.
DATA RATES
CONTROL/INERTIAL
MESSAGE FORMATS
CONTROL DATA
BANDWIDTH
(-90° PHASE POINT)
1
1
1
1
ASYNC
1800/300 Hz
0x04/0x05
97 Hz Gyro
155 Hz Accelerometer
1
1
1
0
ASYNC
600/100 Hz
0x0C/0x0D
1
1
0
1
ASYNC
600/100 Hz
0x0C/0x0D
90Hz
1
1
0
0
ASYNC
600/100 Hz
0x0C/0x0D
50Hz
1
0
1
1
SPI
1800/300 Hz
0x04/0x05
97 Hz Gyro
155 Hz Accelerometer
1
0
1
0
SPI
600/100 Hz
0x0C/0x0D
1
0
0
1
SPI
600/100 Hz
0x0C/0x0D
90Hz
1
0
0
0
SPI
600/100 Hz
0x0C/0x0D
50Hz
0
1
1
1
CAN2A
600/100 Hz
11 Bit ID
90Hz
0
1
1
0
CAN2A
600/100 Hz
11 Bit ID
50Hz
0
1
0
1
CAN2B
600/100 Hz
29 Bit ID
90Hz
0
1
0
0
CAN2B
600/100 Hz
29 Bit ID
50Hz
0
0
1
1
SPARE
NA
NA
NA
0
0
1
0
SPARE
NA
NA
NA
0
0
0
1
SPARE
NA
NA
NA
0
0
0
0
SPARE
NA
NA
NA
Asynchronous Protocol
The asynchronous 1800/300 Hz data protocol is as specified in Table 3 – Control Message (0x04)
Format and Table 7 – Inertial Message (0x05) Format.
The asynchronous 600/100 Hz data protocol is as specified in Table 8 – Control Message (0x0C)
Format and Table 9 – Inertial Message (0x0D) Format.
The transmit baud rate will be 1Mbits/sec with 1 start bit, 8 data bits, 1 stop bit, and no parity.