Honeywell HE220 Скачать руководство пользователя страница 2

HE220, HE260 HUMIDIFIER AND INSTALLATION KIT

69-1645EF

2

Determining Best Location for Humidifier

CAUTION

Temperature and Static Pressure Hazard.
Can cause property or equipment damage.

Locate humidifier where ambient temperature is 
between 32°F (0°C) and 160°F (71°C). 
Do not install humidifier where freezing 
temperatures could occur. 
Be sure supply plenum static pressure is no 
greater than 0.4 in. wc and water pressure is no 
greater than 124 psi.

Select a location for the humidifier on the supply 
(warm air stream) plenum. See Fig. 1.

Select a location that cannot damage the air 
conditioner A-coil during installation.

Do not locate the humidifier on the furnace body.

Allow adequate clearance in front of and above the 
humidifier so you can easily remove the cover to 
perform routine maintenance. 

Mount the humidifier at least 3 in. (78 mm) above 
the furnace body to allow adequate space for the 
solenoid valve and drain line.

Mount the humidifier in a conditioned space to 
prevent freezing.

Fig. 1. Typical humidifier installation locations.

Selecting Water Supply Location

Use either hard or soft water in the humidifier and 
either hot or cold water. The water flow rate, with the 
humidifier running, is 3.5 gal/hr (13 liters/hr) to flush 
the pad and provide moisture for evaporation. 

Make sure that the 20 ft (6.2m) of feed water tubing 
provided is adequate to connect the water supply 
(saddle valve) with the humidifier solenoid valve.

Locating Closest Floor Drain 

Select location with access to a floor drain to provide 
drainage for air conditioner condensation and 
humidifier drainage.

If you do not have a drain available, we recommend 
that you install the Honeywell Whole House Drum or 
Disk Humidifier. Make sure that the 10 ft (3.1m) of 
drain tubing is adequate to reach from the humidifier 
drain connection to the floor drain. 

Selecting Location for Sail Switch

Select a location for the sail switch in the cold air 
return duct where the sail is in the direct path of an 
unrestricted air stream.

Sail switch detects when furnace fan is operating.

Select a location where the air duct is at least 12 in. 
(305 mm) deep and 8 in. (203 mm) wide to allow 
operation of the sail without affecting the smooth flow 
of air in the duct. 

Airflow at the location can be vertical (up or 
down) or horizontal.

IMPORTANT

Mounting the S688 in warm air supply duct can 
reduce the sail life.

Mount the switch at least 6 in. (152 mm) upstream 
from an elbow or junction, and at least 15 in. 
(381 mm) downstream from an elbow or junction. 

Locate the switch on the opposite side of the duct 
from the air entrance. (See Fig. 1-3 in S688 
Installation Instructions.) 

Selecting Location for Humidistat

Select a location for the humidistat on the return 
plenum or on the wall in the living space. 

Mounting on the return plenum is the easiest 
installation for the control wiring circuit.

For return duct mounting, the humidistat should be 
mounted upstream from the humidifier or bypass so that 
it is properly sensing the relative humidity of the living 
space. Locate the control at least 8 in. (203 mm) 
upstream from the humidifier in the return air duct. (See 
Fig. 2.)

Fig. 2. Selecting duct location for humidistat.

Locating Closest 120V Electrical Outlet

Select location with access to an outlet. If not 
available, contact an electrician to have one installed.

Make sure that the humidifier cord is adequate to 
reach from the humidifier to the outlet.

Make sure that the 20 ft (6.2m) of thermostat wire is 
adequate to reach from the humidifier solenoid, to the 
sail switch, to the humidistat. 

M12808A

HORIZONTAL

DOWN

FLO

LOWBOY

RETURN

RETURN

RETURN

HIGHBOY

RETURN

ALTERNATE LOCATION

RETURN 
AIR

RETURN 
AIR

6 in. (152 mm) 
MINIMUM

15 in. (381 mm) 
MINIMUM

BEST 
LOCATION

RETURN AIR DUCT

M12831

Содержание HE220

Страница 1: ...equired for installation INSTALLATION Preparing for the Installation Be sure to identify all the required Table 1 accessories included and make sure the appropriate tools are available before beginning the installation Required Accessories Included Required Tools Tools required for installation include Tin snip Screwdriver Adjustable or open end wrench Drill punch or awl Level Table 1 Required Acc...

Страница 2: ...reach from the humidifier drain connection to the floor drain Selecting Location for Sail Switch Select a location for the sail switch in the cold air return duct where the sail is in the direct path of an unrestricted air stream Sail switch detects when furnace fan is operating Select a location where the air duct is at least 12 in 305 mm deep and 8 in 203 mm wide to allow operation of the sail w...

Страница 3: ... is level then position it in the opening so the plastic tabs are in place on the lower sheet metal edge of the open ing Use pliers as necessary to flatten cut edges See Fig 4 8 Secure the humidifier housing to the opening at the top and bottom using sheet metal screws Fig 4 Installing humidifier on duct 9 Use the 6 in 155 mm starter collar as a template to mark the opening for the bypass 10 Caref...

Страница 4: ...water supply line at the location selected See Fig 8 If tapping into galvanized pipe drain line and pre drill 3 17 in tap for saddle valve NOTE The saddle valve is not designed to regulate water flow The valve is either open or closed IMPORTANT To prevent debris from clogging the solenoid in line filter be sure to install the saddle valve han dle pointing toward the ceiling Fig 8 Installing the sa...

Страница 5: ...s attached Be sure to select air flow direction and remove spring s not required for installation Fig 11 Adapting sail switch to air flow direction or mounting position Vertical downward air flow Leave the spring in place that is attached to the bracket marked Down Remove the spring that is attached to the bracket marked Up Vertical upward air flow Leave the spring in place that is attached to the...

Страница 6: ...t with the arrow up 6 Secure the base to the duct using the four 1 in 25 mm mounting screws provided with humi distat 7 Connect the low voltage wires to the leads and replace the H8908 case See Fig 14 NOTE For wall mounting instructions see the H8908 Installation Instructions Fig 14 Humidistat base and rear view WIRING CAUTION Hazardous Voltage Can cause personal injury or equipment damage Disconn...

Страница 7: ... created when warm air blows over a water soaked area As the vapor circulates the relative humidity rises Your humidity control monitors the relative humidity and activates the humidifier accordingly The humidifier has a water supply that dispenses water evenly over a humidifier pad The warm dry air from the furnace passes over the humidifier pad and picks up the moist air to circulate it througho...

Страница 8: ...y mineral depos its 11 Flush the drain hose with pressurized water a run ning tap to clean the hose 12 Reattach the drain hose to the drain fitting 13 Slide the humidifier pad back into the frame 14 Snap the water nozzle back on the tray 15 Reattach the tray to the frame 16 Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely seated Be careful not ...

Страница 9: ...ng Verify plumbing connections Check for kinks Saddle valve Verify that needle pierces water line and then backs out needle to open valve Humidifier Remove cover and verify that water flows into distribution tray Drain tubing Verify no obstructions Air leakage Check duct joints Seal with duct tape Low humidity Furnace blower not operating Reset circuit breaker or check for blown fuse Check that th...

Страница 10: ...the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARR...

Страница 11: ...HE220 HE260 HUMIDIFIER AND INSTALLATION KIT 11 69 1645EF ...

Страница 12: ... INSTALLATION KIT Printed in U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Страница 13: ...s les accessoires nécessaires à l installation INSTALLATION Avant d installer ce produit Il est important d identifier tous les accessoires nécessaires fournis énumérés au Tableau 1 et d avoir sous la main les bons outils Accessoires nécessaires fournis Tableau 1 Accessoires nécessaires Outils nécessaires Les outils nécessaires à l installation Cisailles à tôle Tournevis Clé ouverte ou réglable Pe...

Страница 14: ...vec accès au siphon de sol pour l évacuation de la condensation du climatiseur et la vidange de l humidificateur S il n y a pas de siphon à proximité il est préférable d installer l humidificateur central à tambour ou à disque de Honeywell S assurer que le tuyau de vidange de 3 1 m 10 pi est suffisamment long et permet de raccorder le tuyau de vidange de l humidificateur au siphon de sol Choix de ...

Страница 15: ...ise au niveau assure le rendement optimal de l humi dificateur 3 Prendre le gabarit dans la boîte pièce 69 1950 Dans le cas du modèle HE220 découper le gabarit suivant la ligne pointillée 4 Fixer le gabarit avec du ruban adhésif et en tracer le contour 5 Enlever le gabarit et découper soigneusement une ouverture rectangulaire 6 6 Démonter l humidificateur enlever le couvercle et retirer l ensemble...

Страница 16: ...ition fermée correspond à Été et la position ouverte à Hiver Voir la Fig 6 Fig 6 Installation du collet de raccordement 12 Enlever la pellicule sur l adhésif en mousse Placer le collet de raccordement autour de l ouver ture 13 Glisser un bout de la gaine flexible sur le collet de raccordement et l attacher au moyen d une cour roie de fixation 14 Introduire le collet lisse dans l orifice de l humid...

Страница 17: ...a garniture en laiton à l extrémité du tuyau c Glisser l anneau de compression en plastique sur le tuyau Mettre de côté l anneau de com pression en cuivre fourni avec le robinet REMARQUE Pour empêcher les fuites avec des tuyaux en plastique utiliser des anneaux en plastique Delrin N utiliser des anneaux en cuivre qu avec des tuyaux en cuivre d Insérer le tuyau dans le raccord de l électro vanne et...

Страница 18: ...sort attaché au support marqué Up Enlever le support attaché au support marqué Down Courant d air horizontal Enlever les deux ressorts 1 Placer le gabarit fourni avec l interrupteur à ailette à l endroit choisi REMARQUE S assurer que la flèche indiquant le sens de la circulation de l air pointe dans la bonne direction a Dans le cas d un montage horizontal placer le long côté horizontalement à l ai...

Страница 19: ...uctions d installation du H8908 Fig 14 Socle et vue arrière de l humidistat CÂBLAGE MISE EN GARDE Risque de choc électrique Peut causer des blessures ou des dommages matériels Couper l alimentation électrique avant de faire l installation ou l entretien IMPORTANT Tout le câblage doit être conforme aux codes et règlements locaux Câbler l électrovanne de l humidificateur l interrupteur à ailette l h...

Страница 20: ...épartit uniformément l eau sur l écran évaporateur de l humidificateur L air sec et chaud qui sort de l appareil de chauffage passe sur l écran évaporateur de l humidificateur et capte l air humide pour le faire circuler dans la maison L air humidifié est plus chaud et il assure un meilleur confort Le point de consigne du thermostat peut donc être abaissé ce qui permet de diminuer les coûts de cha...

Страница 21: ...le écran évaporateur d humidifica teur dans le boîtier de l humidificateur en appuyant jusqu à ce qu il soit bien en place S assurer que le tuyau d arrivée d eau n est ni écrasé ni plié 17 Remettre le couvercle sur l humidificateur 18 Pour vérifier le fonctionnement de l humidificateur se reporter à la section Vérification du fonctionne ment de l humidificateur Fin de la saison d humidification À ...

Страница 22: ...vanne Tuyauterie Vérifier les raccords des tuyaux Vérifier si les tuyaux sont pincés Robinet vanne à étrier Vérifier si le pointeau perce la ligne d eau et revient en position pour ouvrir le robinet vanne Humidificateur Enlever le couvercle et vérifier si l eau s écoule dans le plateau de distribution Tuyau de vidange Vérifier s il y a blocage Fuite d air Vérifier les joints des gaines Sceller ave...

Страница 23: ...ll se limite à réparer ou à remplacer le produit conformément aux modalités susmentionnées HONEYWELL N ASSUME AUCUNE RESPONSABILITÉ POUR QUELQUE DOMMAGE INDIRECT QUE CE SOIT RÉSULTANT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU TACITE APPLICABLE AU PRÉSENT PRODUIT Certains territoires et provinces ne permettent pas l exclusion ou la restriction des dommages indirects et par conséquent la...

Страница 24: ...ation 69 1645EF G H 9 02 www honeywell com yourhome HUMIDIFICATEURS HE220 ET HE260 ET TROUSSE D INSTALLATION Solutions de régulation et d automatisation Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: