Appendix 

 

9. Appendix 

 

9.1.  Help with problems 

 

Problem Cause 

Remedy 

Batteries 
inserted 
incorrectly 

 

Insert the batteries 
correctly. 

Teach-in failed 

Radio 
connection 
failure  

 

Eliminate interference 
sources (metal, wireless 
devices). 

 

Correct installation site. 

 

Repeat the teach-in. 

HC60NG does 
not react to set 
point changes 
on HCW 80 

HC60NG 
and HCW 
80 not 
bound 

 

Reset HC60NG.

 

 

Follow the teach-in 
procedure as described 
in section “3.3”. 

Teach-in 
procedure 
incorrect/ 
incomplete 

 

Repeat the teach-in. 

After teach-in 
red LED is on 
and green LED 
is flashing once 
every 3 sec 

Position of 
HCW 80 
incorrect 

 

Repeat the teach-in 
keeping approx. 1 m 
distance between HCW 
80 and

 HC60NG.

 

Communi-
cation loss 
RF signal 
blocked 

 

Relocate the HCW 80 
(see section “3.2”). 

Red LED of the 
HC60NG is on 

Batteries of 
HCW 80 
exhausted 

 

Replace batteries in 
HCW 80 
(see section “8”). 

 

9.2. Technical 

data 

 

Batteries 

1.5 V, type LR06, AA 

Frequency 868.3 

MHz 

(transmitter) 

Operating temperature  0 °C to 50 °C 
Storage temperature 

–20 °C to 70 °C 

Humidity 

5 % to 90 % relative humidity 

 

9.3.  Device and function definition in 

accordance with EN 60730-1 

• 

Purpose of the device is temperature controlling 

• 

Device fulfils Protection class 1, EN 60730-1 

• 

Independently installable electronic control system 
with fixed installation 

• 

Type of action is Type 1.8 

• 

Temperature of ball thrust hardness test for 
housing components 75 °C and for live parts such 
as, for example, terminals 125 °C 

• 

EMC emitted interference test at 230 V

, 50 HZ 

maximum 

• 

Pollution severity is 2 

• 

Rated voltage is 4000 V (corresponding to 
Overvoltage category III) 

• 

Software class is A 

 

9.4. WEEE 

directive 2002/96/EC – Waste 

Electrical and Electronic Equipment 
directive 

 

 

At the end of the product life dispose of 
the packaging and product in a 
corresponding recycling centre.

 

 

Do not dispose of the unit with the usual 
domestic refuse.

 

 

Do not burn the product. 

 
 

Содержание HCW 80

Страница 1: ...HCW 80 Wireless Room Thermostat Y6630D1007 Installation and Operation ...

Страница 2: ......

Страница 3: ...terference of the relay module HC60NG in the device through metallic objects or further frequency devices Mount the device with a distance of at least 30 cm to metallic objects such as wall boxes or boiler housings according to the DECT standard etc Do not mount on metal wall boxes 2 Overview The room unit HCW 80 is used for intelligent room temperature control It controls a single heating system ...

Страница 4: ...the terminal covers 7 mm Æ 7 mm Æ Fig 4 Connecting the relay module to the power supply max 2 5 mm2 Fig 5 Wiring the terminal Caution Incorrect wiring Install in accordance with local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label ...

Страница 5: ...sufficient distance to metallic objects Mount the device with a distance of at least 1 m to radio devices such as radio headphones cordless phones according to the DECT standard etc Select another installation site if the radio interference cannot be rectified Fig 8 Positioning the room unit HCW 80 Place the room unit HCW 80 at the installation site but do not install it yet Remove the housing cov...

Страница 6: ...in operation The time out is after 5 min 3 3 2 Failed teach in If the teach in has failed See section 3 3 1 Assignment to the relay module HC60NG Improve the data transfer Improving the data transfer When selecting the operating site of each device ensure that the distance to radio devices such as radio headphones cordless phones etc according to the DECT standard amounts to at least 1 m Do not in...

Страница 7: ...e adjustment dial see Fig 13 7 2 Limiting the adjustment range You can limit the adjustment range that can be used at the adjustment dial Remove the housing cover see Fig 9 Page 5 Fig 14 Limiting the adjustment range Place the two small pins into the holes of the adjustment dials in order to limit the adjustment range see Fig 14 Orientate yourself on the basis of the inner scale In Fig 14 the pins...

Страница 8: ...80 see section 8 9 2 Technical data Batteries 1 5 V type LR06 AA Frequency 868 3 MHz transmitter Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Humidity 5 to 90 relative humidity 9 3 Device and function definition in accordance with EN 60730 1 Purpose of the device is temperature controlling Device fulfils Protection class 1 EN 60730 1 Independently installable electronic contr...

Страница 9: ......

Страница 10: ...ywell com The right is reserved to make modifications This document is definitive for the enclosed product and replaces all previous publications Honeywell Inc hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999 5 EC The declaration of conformity of the product can be requested from the manufacturer Note to non EU countries This pr...

Отзывы: