Honeywell HCW 80 Скачать руководство пользователя страница 10

 

 

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative:

 

 
Honeywell GmbH 

Böblinger Straße 17 
71101 Schönaich, Germany 
Tel.: (++49) (0) 7031 637 01 
Fax: (++49) (0) 7031 637 493 
http://europe.hbc.honeywell.com 

The right is reserved to make 
modifications

 

 

This document is definitive for the enclosed product and replaces all previous publications. 
Honeywell Inc. hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999/5/EC. The declaration of 
conformity of the product can be requested from the manufacturer. 
Note to non-EU countries: This product may only be used if operation in the 868 MHz frequency band is permissible. 

 

### to change: MU2H-0310 GE51R0805 

   

 

Содержание HCW 80

Страница 1: ...HCW 80 Wireless Room Thermostat Y6630D1007 Installation and Operation ...

Страница 2: ......

Страница 3: ...terference of the relay module HC60NG in the device through metallic objects or further frequency devices Mount the device with a distance of at least 30 cm to metallic objects such as wall boxes or boiler housings according to the DECT standard etc Do not mount on metal wall boxes 2 Overview The room unit HCW 80 is used for intelligent room temperature control It controls a single heating system ...

Страница 4: ...the terminal covers 7 mm Æ 7 mm Æ Fig 4 Connecting the relay module to the power supply max 2 5 mm2 Fig 5 Wiring the terminal Caution Incorrect wiring Install in accordance with local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label ...

Страница 5: ...sufficient distance to metallic objects Mount the device with a distance of at least 1 m to radio devices such as radio headphones cordless phones according to the DECT standard etc Select another installation site if the radio interference cannot be rectified Fig 8 Positioning the room unit HCW 80 Place the room unit HCW 80 at the installation site but do not install it yet Remove the housing cov...

Страница 6: ...in operation The time out is after 5 min 3 3 2 Failed teach in If the teach in has failed See section 3 3 1 Assignment to the relay module HC60NG Improve the data transfer Improving the data transfer When selecting the operating site of each device ensure that the distance to radio devices such as radio headphones cordless phones etc according to the DECT standard amounts to at least 1 m Do not in...

Страница 7: ...e adjustment dial see Fig 13 7 2 Limiting the adjustment range You can limit the adjustment range that can be used at the adjustment dial Remove the housing cover see Fig 9 Page 5 Fig 14 Limiting the adjustment range Place the two small pins into the holes of the adjustment dials in order to limit the adjustment range see Fig 14 Orientate yourself on the basis of the inner scale In Fig 14 the pins...

Страница 8: ...80 see section 8 9 2 Technical data Batteries 1 5 V type LR06 AA Frequency 868 3 MHz transmitter Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Humidity 5 to 90 relative humidity 9 3 Device and function definition in accordance with EN 60730 1 Purpose of the device is temperature controlling Device fulfils Protection class 1 EN 60730 1 Independently installable electronic contr...

Страница 9: ......

Страница 10: ...ywell com The right is reserved to make modifications This document is definitive for the enclosed product and replaces all previous publications Honeywell Inc hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999 5 EC The declaration of conformity of the product can be requested from the manufacturer Note to non EU countries This pr...

Отзывы: