OPERATION

How Your Humidifier Works

Your Honeywell humidifier uses the principle that vapor 
(evaporated water) is created when warm air blows over 
a water-soaked area. As the vapor circulates, the relative 
humidity rises.

Your humidity control monitors the relative humidity and 
activates the humidifier accordingly. The humidifier has a 
water supply that dispenses water evenly over a 
humidifier pad. The warm dry air, from the furnace, 
passes over the humidifier pad and picks up the moist air 
to circulate it throughout your home.

Humidified air feels warmer and more comfortable so you 
may be able to lower your thermostat heating setpoint, 
which saves money on your heating fuel bills. The end 
result is that your humidifier gives you a comfortable 
environment that is also energy efficient.

Controlling Your Humidity Settings

Your H8908 Humidistat controls your humidifier. 

• Choose the humidity control setting using the 

combination of relative humidity/outdoor temperature 
setting scale on your humidity control dial. 

• Match the dial setting to the outdoor temperature to 

optimize the humidity level while reducing the 
moisture condensation on your windows. See Table 2 
to adjust the humidity control to the recommended 
setting.

NOTE: As the outside temperature drops, a lower 

humidity setting is recommended to accommo-
date dewpoint effects. These settings should 
reduce the accumulation of moisture and ice on 
windows and other areas of the home.

• Adjust the humidity control setting to adjust for indoor 

activities such as cooking, showering and clothes 
drying, which can cause excessive levels of humidity 
that can accumulate moisture on your windows.

NOTE: If these activities persist for more than a few 

hours, set the humidity control to the lowest set-
ting to turn off the humidifier. If the condition 
does not improve, ventilate your home to 
remove the moisture.

MAINTAINING YOUR HUMIDIFIER

A regular maintenance program prolongs the life of your 
humidifier and makes your home more comfortable. The 
frequency of cleaning depends on the condition of your 
water. 

You can use either hard or soft water in your humidifier, 
but hard water mineral deposits are more difficult to clean 
than soft water deposits. 

Use the following procedure to clean your Honeywell 
humidifier.

WARNING

Serious Personal Injury Hazard. 
Can cause electrical shock and injury from 
moving parts.

Disconnect power and shut off water supply 
before removing cover.

IMPORTANT

Never oil any part of the humidifier.

Every 1 to 3 Months (Depending on Water 

Quality)

1.

Disconnect the power and turn off the humidifier 
water supply.

2.

Remove the humidifier cover by unplugging the 
connector and loosening the thumb screw. Grasp 
the cover near the bottom and pull toward you. See 
Fig. 14.

3.

Remove the humidifier pad assembly from the 
humidifier by grasping the top of the tray and pull-
ing it toward you.

4.

Lift the tray off the pad.

5.

Gently pinch the water nozzle catches inward until 
you can lift the water nozzle off the tray.

6.

Carefully remove any mineral deposits from the 
tray and frame. Be sure the frame drain hole has 
nothing blocking it.

Fig. 14. Cleaning your humidifier.

Table 2. Setting Your Humidistat.

When Outside 

Temperature is:

Use This Control 

Setting:

-20°F (-29°C)

15

-10°F (-23°C)

20

0°F (-18°C)

25

+10°F (-12°C)

30

+20°F (-7°C)

35

Above 20°F (-7°C)

40

M12809

COVER 
ASSEMBLY

HUMIDIFIER 
PAD ASSEMBLY

FEED TUBE NOZZLE

WATER 
DISTRIBUTION TRAY

HUMIDIFIER
HOUSING

THUMB 
SCREW

69-1646E-01_A.fm  Page 7  Tuesday, June 9, 2009  1:13 PM

Содержание H8908

Страница 1: ... the installation Required Accessories Included Required Tools Tools required for installation include Tin snip Screwdriver Adjustable or open end wrench Drill punch or awl Level Determining Best Location for Humidifier CAUTION Temperature and Static Pressure Hazard Can cause property or equipment damage Locate humidifier where ambient temperature is between 32 F 0 C and 160 F 71 C Do not install ...

Страница 2: ...ail without affecting the smooth flow of air in the duct Airflow at the location can be vertical up or down or horizontal IMPORTANT Mounting the S688 in warm air supply duct can reduce the sail life Mount the switch at least 6 in 152 mm upstream from an elbow or junction and at least 15 in 381 mm downstream from an elbow or junction Locate the switch on the opposite side of the duct from the air e...

Страница 3: ...ing humidifier on duct 11 Reinstall the humidifier pad assembly in the humid ifier housing IMPORTANT Be sure to reconnect the water feed tube and ensure that the tube is not pinched or kinked 12 Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover Connecting the Plumbing Use hot or cold water and either hard or softened water in the humidifier 1 Shut off the w...

Страница 4: ...tube to the humid ifier drain fitting and run to the floor drain see Fig 8 a Slide the drain clamp over the tubing b Push the tubing over the drain nipple on the humidifier c Hand tighten the clamp around the tubing to secure the humidifier drain d Fasten the drain tubing can use duct tape along the route to prevent movement and ensure downward slope for correct drainage NOTE Cut tubing to correct...

Страница 5: ... Off position the sail should point into the direction of airflow as shown in Fig 11 Fig 11 Inserting sail switch in direction of airflow 6 Secure the switch by using the sheet metal screws provided 7 After wiring snap on the cover Installing the Humidistat Installing on Mounting Duct 1 Apply the template to the duct location chosen for the humidistat Make sure the template is level before drillin...

Страница 6: ... white con ductors to the Com and NO sail switch terminals NC terminal is not used TESTING HUMIDIFIER OPERATION Checklist q Humidifier is level q Control wiring was reviewed using circuit diagram q Humidifier is plugged in q Feed line has no kinks q Drain line slopes continuously down and ends at floor drain q Water hose inside humidifier is connected to PerfectFlow water distribution tray After i...

Страница 7: ...t can accumulate moisture on your windows NOTE If these activities persist for more than a few hours set the humidity control to the lowest set ting to turn off the humidifier If the condition does not improve ventilate your home to remove the moisture MAINTAINING YOUR HUMIDIFIER A regular maintenance program prolongs the life of your humidifier and makes your home more comfortable The frequency o...

Страница 8: ... the water feed tube is placed in the guide slots 15 Replace the humidifier cover 16 Verify the humidifier operation by following the steps in the Checking Your Humidifier for Correct Operation section CHECKING YOUR HUMIDIFIER FOR CORRECT OPERATION After winter startup or servicing use the following steps to check your humidifier operation 1 Turn on the humidifier power and water supply 2 Turn the...

Страница 9: ...Verify plumbing connections Check for kinks Saddle valve Verify that needle pierces water line and then backs out needle to open valve Humidifier Remove cover and verify that water flows into distribution tray Drain tubing Verify no obstructions Low humidity Furnace blower not operating Reset circuit breaker or check for blown fuse Check that the furnace power is on Check all external wiring conne...

Страница 10: ...WELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WAR...

Страница 11: ...HE360 HUMIDIFIER AND INSTALLATION KIT 11 69 1646EF 01 69 1646E 01_A fm Page 11 Tuesday June 9 2009 1 13 PM ...

Страница 12: ... U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 69 1646E 01_A fm Page 12 Tuesday June 9 2009 1 13 PM ...

Страница 13: ...HE360 et un humidistat H8908 de Honeywell ainsi que tous les accessoires nécessaires à l installation INSTALLATION Avant d installer ce produit Il est important d identifier tous les accessoires nécessaires fournis énumérés au Tableau 1 et d avoir sous la main les bons outils Accessoires nécessaires fournis Tableau 1 Accessoires nécessaires Outils nécessaires Les outils nécessaires à l installatio...

Страница 14: ...ficateur S il n y a pas de siphon à proximité il est préférable d installer l humidificateur central à tambour ou à disque de Honeywell S assurer que le tuyau de vidange de 3 1 m 10 pi est suffisamment long et permet de raccorder le tuyau de vidange de l humidificateur au siphon de sol Choix de l emplacement de l interrupteur à ailette Choisir un endroit dans la gaine de reprise d air froid où l i...

Страница 15: ...igneusement une ouverture rectangulaire 6 Démonter l humidificateur enlever le couvercle et retirer l ensemble écran évaporateur Voir la Fig 3 Fig 3 Démontage de l humidificateur 7 Placer les pinces de fixation comme l indique la Fig 4 Fig 4 Position des pinces de fixation 8 S assurer que le boîtier de l humidificateur est de niveau puis le placer de manière que les attaches de plastique soient su...

Страница 16: ...rémité du tuyau c Glisser l anneau de compression en plastique sur le tuyau Mettre de côté l anneau de com pression en cuivre fourni avec le robinet REMARQUE Pour empêcher les fuites avec des tuyaux en plastique utiliser des anneaux en plastique Delrin N utiliser des anneaux en cuivre qu avec des tuyaux en cuivre d Insérer le tuyau dans le raccord de l électro vanne et serrer l écrou de compressio...

Страница 17: ...p Enlever le support attaché au support marqué Down Courant d air horizontal Enlever les deux ressorts 1 Placer le gabarit fourni avec l interrupteur à ailette à l endroit choisi REMARQUE S assurer que la flèche indiquant le sens de la circulation de l air pointe dans la bonne direction a Dans le cas d un montage horizontal placer le long côté horizontalement à l aide d un niveau b Dans le cas d u...

Страница 18: ...ISE EN GARDE Risque de choc électrique Peut causer des blessures ou des dommages matériels Couper l alimentation électrique avant de faire l installation ou l entretien IMPORTANT Tout le câblage doit être conforme aux codes et règlements locaux Câbler l électrovanne de l humidificateur l interrupteur à ailette l humidistat et le transformateur Voir la Fig 13 Fig 13 Câblage des appareils 1 Passer l...

Страница 19: ...l appareil de chauffage passe sur l écran évaporateur de l humidificateur et capte l air humide pour le faire circuler dans la maison L air humidifié est plus chaud et il assure un meilleur confort Le point de consigne du thermostat peut donc être abaissé ce qui permet de diminuer les coûts de chauffage Avec un humidificateur la maison devient confortable et éconergétique Réglage de l humidificate...

Страница 20: ...e tuyau de vidange avec de l eau sous pression eau du robinet pour le nettoyer 11 Replacer le tuyau de vidange sur le raccord de vidange 12 Replacer le gicleur sur le plateau 13 S assurer que la partie marquée de l écran évapo rateur est orientée vers le haut Remettre le pla teau sur le cadre 14 Mettre l ensemble écran évaporateur d humidifica teur dans le boîtier de l humidificateur en appuyant j...

Страница 21: ...ectrovanne Tuyauterie Vérifier les raccords des tuyaux Vérifier si les tuyaux sont pincés Robinet vanne à étrier Vérifier si le pointeau perce la ligne d eau et revient en position pour ouvrir le robinet vanne Humidificateur Enlever le couvercle et vérifier si l eau s écoule dans le plateau de distribution Tuyau de vidange Vérifier s il y a blocage Faible humidité Le ventilateur de l appareil de c...

Страница 22: ...placer le produit conformément aux modalités susmentionnées HONEYWELL N ASSUME AUCUNE RESPONSABILITÉ POUR QUELQUE DOMMAGE INDIRECT QUE CE SOIT RÉSULTANT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU TACITE APPLICABLE AU PRÉSENT PRODUIT Certains territoires et provinces ne permettent pas l exclusion ou la restriction des dommages indirects et par conséquent la présente restriction peut ne p...

Страница 23: ...HUMIDIFICATEURS HE360 ET TROUSSE D INSTALLATION 11 69 1646EF 01 69 1646F 01_A fm Page 11 Wednesday June 10 2009 2 22 PM ...

Страница 24: ...09 www honeywell com yourhome HUMIDIFICATEURS HE360 ET TROUSSE D INSTALLATION Solutions de régulation et d automatisation Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 69 1646F 01_A fm Page 12 Wednesday June 10 2009 2 22 PM ...

Отзывы: