background image

GSMX Installation and Setup Guide 

 

– 3 – 

 

Monitor and control their security system from a website  

 

Receive e-mail and text message notifications of system events  

 

Control the system and receive confirmations using text messages  

Dealers can enroll their customers for "Remote Services" by using the 

AlarmNet Direct website.  Once enabled, the specific programming fields 
associated with these features can be programmed into the communications 

device either remotely using the AlarmNet Direct website or locally using the 

7720P programming tool. 

 

E-mail notification (Multi Mode) is intended as a convenience 
for the user, and does not replace Central Station reporting of 

critical events (alarms, troubles, etc.). 

 

Testing the System 

After installation the security system should be tested.  Refer to the control 

panel installation instructions for procedures to test the entire system. 

Compatibility 

The GSMX functions with any control panel that utilizes a Honeywell ECP 
bus and supports Long Range Radio. 

Compliance 

This device has been tested by ETL to meet the following standards: 

 

UL985 – Residential Fire 

 

 

UL1023 – Residential Burg 

 

 

Mounting and Wiring the Module 

Select a Mounting Location 

When choosing a suitable mounting location, understand that it must be 

mounted indoors, and for best signal strength it should be mounted 
vertically.  Signal strength is very important for proper operation.  For most 

installations, mounting the unit on the control panel provides adequate 

signal strength and we suggest that this method is tried first.  Especially if 
the control panel is not in a basement location or in an area that contains 

large metal objects. 

If the control panel location does not provide adequate signal strength, then 
the module can be mounted remotely.  

Содержание GSMX

Страница 1: ...G GS SM MX X G GS SM M C Co om mm mu un ni ic ca at to or r I In ns st ta al ll la at ti io on n a an nd d S Se et tu up p G Gu ui id de e REG TX RX FAULT SIGNAL 800 04432 9 09 Rev B ...

Страница 2: ...0 Using the Control Panel 10 Programming for ECP Mode 10 Programming for 4204 and Two 4204 Emulation Modes 11 4204 Emulation Mode Options 11 Programming Options 13 ECP Status Codes 18 Exiting the Programming Mode 19 Setting Factory Defaults 19 Registering the Module 20 Registering through the AlarmNet Direct Website 20 Remote Services 21 Registering Using the Test Message Registration Switch 21 Re...

Страница 3: ... will attempt to send a transmission via SMS Short Message Service also known as a text message ULC SMS has not been evaluated for ULC central station communication Features Reports fire burg and status messages via GSM Internal antenna provides additional security Simple programming using the 7720P programming tool or via the AlarmNet Direct website Uses 2 way ECP communication with the control S...

Страница 4: ...d the receiver know the KEY used to encrypt the data Each device produced by Honeywell is loaded with a unique identifier called a MAC number and a large random number or KEY This KEY and MAC number are also stored in the AlarmNet servers When a device contacts AlarmNet it sends the MAC number followed by the message that is encrypted using the KEY data The server looks up the MAC number and uses ...

Страница 5: ...d Refer to the control panel installation instructions for procedures to test the entire system Compatibility The GSMX functions with any control panel that utilizes a Honeywell ECP bus and supports Long Range Radio Compliance This device has been tested by ETL to meet the following standards UL985 Residential Fire UL1023 Residential Burg Mounting and Wiring the Module Select a Mounting Location W...

Страница 6: ...n label inside module You may log out of the AlarmNet Direct website Once the module is installed and programmed it must be Registered with AlarmNet Registering activates the account with AlarmNet and enables the security system s control panel to send reports Verifying Satisfactory Signal Strength NOTE In this procedure you will temporarily power up the communications module to check for satisfac...

Страница 7: ...e control panel cabinet 2 Open the GSMX cover Remove the Hole Cap attached to the plastic trim as necessary and snap it into the top opening of the enclosure 3 Remove the bottom knockout on the GSMX enclosure for the threaded mount Then install the threaded mount so it snaps into the plastic retaining tabs Mount the GSMX assembly on the cabinet s knockout and fasten with the locking nut 4 Connect ...

Страница 8: ...nsure power to the control panel both AC and battery is off then remove a suitable knockout on the top or side of the control panel cabinet NOTES If in the wall wiring will be used route the wiring through the communications module s rear wiring access hole If surface mounted wiring will be used remove the communications module s bottom knockout and use that to route the wiring 2 Open the GSMX cov...

Страница 9: ...nimum Wire Gauge Distance from Control Panel 22 75 ft 23m 20 120 ft 37m 18 170 ft 52m 16 270 ft 82m 5 Route the wires through the rear wiring access hole or bottom knockout on the GSMX Continue routing the wiring to the control panel A control panel knockout that is presently used can be utilized however DO NOT utilize a control panel knockout that is being used for primary power GSMX 006 V0 ECP C...

Страница 10: ...lect use of the 7720P Programming Tool Using the AlarmNet Direct Website To program the module via the website if you are already signed up for this service go to https services alarmnet com AlarmNetDirect If you are not signed up for this service click on Dealer Sign Up and follow the instructions Log in and follow the on screen prompts Please have the following information available when program...

Страница 11: ...it program mode also can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO answer Y Press for YES answer SHIFT Press before pressing a SHIFT key function Will light SHIFT LED LED goes out once a key is pressed Press again for each SHIFT function desired 1 A 1 For entering the number 1 A For entering letter A 2 B 2 For entering the number 2 B For entering l...

Страница 12: ...ts without changing any values Press the ESC key to go to the end of the list of prompts Using the Control Panel Some control panels support programming of the communications module through the control panel programming mode If using this method of programming only the ECP Mode programming options are available Other mode prompts will not be displayed and the mode cannot be changed For a descripti...

Страница 13: ...lay modules accordingly On VISTA 32FB or higher control panels and First Alert equivalents addresses 6 and 13 should not be used when the secondary 4204 is enabled Messages are sent in ADEMCO High Speed format NOTE See your control panel Installation and Setup Guide for the number of 4204 modules supported 4204 Emulation Mode Options For control panels that do not support LRR ECP communication the...

Страница 14: ...NOT enable the Long Range Radio module in control panel programming Instead enable 4204 relay module address es and program the appropriate relay activation functions for the relay zones being used In some control panels it is called relay programming and in others it is called output device programming It is recommended that close and stay closed usually choice 2 action is selected Selection of m...

Страница 15: ...Y The next prompt appears 3 Program Device Y N _ Y N To begin programming the module press Y and go to Prompt 9 Device Mode To create a password if none has been assigned press N and go to Prompt 4 Create Password To change an existing password press N and go to Prompt 5 Change Password 4 Create Password Y N _ Y N Passwords can be used to protect account and programming information If no password ...

Страница 16: ...mpt is displayed if Y was pressed in Prompt 4 or 5 Enter a 4 digit password 0 9 A F N S T X Y 7 Verify Password 0 9 A F N S T X Y Re enter the password as confirmation If the password doesn t match the first entry the following is displayed followed by the Exit Prog Mode prompt Verify Not OK PSWD not created Otherwise the Exit Prog Mode prompt is displayed directly 8 Exit Prog Mode Y N _ Y N ESC E...

Страница 17: ... are defined on the Honeywell Total Connect website and must correspond to outputs relays programmed in the control panel through Output Device programming The Multi Mode address selected at prompt 11 in the GSMX or at the AlarmNet Direct website must match the address of a 4204 relay module enabled in the control panel although you don t actually connect a module If using 2 4204 sourced the addre...

Страница 18: ...Remote Access enables the user to control the security system using a web browser This feature must be configured at the AlarmNet Direct website as follows Remote Access must be enabled by selecting Enabled at the Remote Access prompt A keypad address must be enabled in the GSMX in order for the module to communicate with the control panel At the Keypad Type prompt select the appropriate Keypad 16...

Страница 19: ...ld Alarm Time 10 Minutes _ 10 Minutes 15 Minutes 30 Minutes 1 Hour 2 Hours 4 Hours 8 Hours 12 Hours 24 Hours The old alarm time sets how long an undeliverable alarm is retried for delivery to the central station If the message is not validated it is retried until the old alarm time is reached or the message is validated Press the space key to scroll through choices UL NOTE Must be 10 minutes 20 GS...

Страница 20: ...us Codes The GSMX sends status messages to the control panel to report various failures Some control panels e g VISTA 10P VISTA 15P and VISTA 20P Series display these status codes on the keypad as LngRng Radio followed by a 4 digit code Commercial panels can supervise the communicator module by way of its ECP address ex 03 For example if the module is disconnected if it s not registered or the SIM...

Страница 21: ...prompts will be displayed Follow the steps shown below until the upload is successful Display Description What to do Cannot Upload Try Again Y N_ GSM Communicator has not yet initialized Wait for SIGNAL green LED to be lit Press Y Failed to Update Root File Network problem or you answered N to Cannot Upload Try Again prompt Initiate the Force Server Update command by pressing the 0 key Setting Fac...

Страница 22: ... TX RX yellow LED is lit to indicate that the power on reset message is waiting to be sent This message will appear at the receiving station as E339 803 The description may read Trouble Exp Mod Reset If registration is not validated within 90 seconds the GSMX times out and the REG green LED will be lit solid Registering through the AlarmNet Direct Website To register the module via the website go ...

Страница 23: ...on The customer will receive another e mail message with their password They will then be able to receive notifications and access their system via the Total Connect website or using their cell phone PDA that supports GSM GPRS and Text Messaging SMS Registering Using the Test Message Registration Switch Initiate the registration sequence by clicking the TEST MESSAGE REGISTRATION switch three times...

Страница 24: ... programming the Primary account information of GSMX for an existing account This prompt appears for 2 seconds See the Replacing an existing module using the programming tool topic Replacing an existing module using the programming tool Enter PIN This prompt appears after pressing the down arrow on the 7720P Enter a 4 digit alphanumeric PIN number provided by your central station your dealer or an...

Страница 25: ...dentification Displays A 7845GSM x x xx mm dd yy Software Revision x x xx indicates the installed software revision Mm dd yy indicates month day and year of the revision B MAC xxxxxxxxxxxx MAC CRC yyyy MAC Address xxxxxxxxxxxx indicates the GSMX s unique identification number yyyy indicates the MAC CRC number These numbers are found on the label on the module as well as the label on the box Press ...

Страница 26: ...G xxxdbm x x GSM Status Display Screen 1 PriRSSI Primary Site RSSI level in dBm GPRS GPRS Service availability where x can be Y if GPRS is available N if GPRS is Not available REG Registration status from communicator module where x can be N Not Registered H Registered Home S Searching D Registration Denied R Registered Roaming Unknown Registration State Press the Space key to go to the next scree...

Страница 27: ...d system fault status Flt Represents communicator faults OK Normal No fault G No network connectivity over GSM and fault time has expired g No network connectivity over GSM and fault time has NOT yet expired T Test Msg Sent Test Alarm Sends a Test alarm to AlarmNet Functional for a registered GSMX only If the device is not registered a message is displayed indicating that the command cannot be exe...

Страница 28: ...ted its initialization and try again ENTER Strt Prog Mode Y N_ Enter Program Mode Press Y to enter program mode otherwise press N Central Station Messages The following messages are sent to the Central Station by AlarmNet for the conditions listed below Alarm Condition ECP Mode 4204 Modes Alarm Code Restore Code Alarm Code Restore Code Power On Reset xx device address E339 C08xx 5551 5555 6 ECP Su...

Страница 29: ...wnloading Glossary AES Advanced Encryption Standard CRC Cyclic Redundancy Check used to confirm validity of MAC ID DACT Digital Automated Communications Terminal ECP Enhanced Console Protocol is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices It uses four wires power ground data in data out GPRS General Packet Radio Service GSM Global System fo...

Страница 30: ...NOTES ...

Страница 31: ...Registration in progress FAULT red ON No contact with network OFF Normal SLOW BLINK Loss of communication with the panel ECP fault FAST BLINK No network contact AND loss of communication with the control panel SIGNAL green ON Minimum required signal strength is present BLINKING Marginal signal strength is present OFF Installation is not recommended ALL FAST BLINK Hardware Error GSMX 010 V0 ECP Cab...

Страница 32: ...ry to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA IC STATEMENTS This device complies with...

Отзывы: