The repeat panel duplicates all of the control panel
indications and the essential controls.

The repeat panel has its own mains derived power
supply with battery for standby power in the event
of mains supply failure. A lockable front door
prevents unauthorised access to fire alarm controls
but allows all of the indicators to be seen. The
panel is designed for semi-flush or surface
mounting and facilitates both rear and top cable
entry points.

This repeat panel can be installed on a loop circuit
of an EN or BS Vigilon fire detection and alarm
system. It can be sited near an entry or exit point
of a building and fit in with the loop cable routing.

Compatibility

The repeat panel is compatible with system control
panel having card and software below:

Control panel

CARD

Control Panel Software

EN54

BS5839

LCC

³

V4.00

³

3.42

LPC

New Shorter

Card ONLY

³

V4.19

³

3.90

MCC

³

V4.11

-

MCB

³

V4.21

-

³

means equal to or greater than

Technical Data

Panel dimensions

height 403mm, width 338mm,
depth 101mm

Weight

9Kg with battery (approximate)

Storage temperature -10°C to +55ºC

Operating
temperature

0°C to +45ºC

Relative humidity
(Non condensing)

Up to 90% temperature
+5°C to +45°C

Battery

12V 7Ah sealed lead acid

Mains operating
voltage

230V -15% +10% 50/60Hz

Rated Current

0.2A

Emission

BS EN61000-6-3 : 2001

Immunity

BS EN50130-4 : 1996 : Part 4

LVD

BS EN 60950-2006

Ingress protection

IP31 (estimated)

Colour

Door - Pantone 422
Back box - Graphite Grey (RAL 7024)

Controls
(with door closed)
Access level 1

Next and Previous buttons operable
during fire condition only.

Control buttons
(with door open)
Access level 2

Sound Alarms, Silence Alarms, Reset
Fire, Cancel Fault Buzzer, Verify,
F1-F4, Menu On/Off and U1-U4.

Indicators

Fire, Verify, Power, Fault, Power Fault,
System Fault, Delay and CB253/254.

EN panel only:

Sounder, Sounder,

Delay, Disablement Test and 32-Fire
Zone LEDs.

BS panel only:

Commission and

Warning.

Display:

8 lines 40 characters per line,

back-lit LCD.

Loop connection

3-way connection to a loop circuit

EN54-17 data
Fire detection and
fire alarm system
short circuit isolators

V

max

42V

V

nom

40V

V

min

24V

V

SO max

16V

V

SO min

8V

I

C max

0.4A

I

S max

1A

I

L max

20

m

A

Z

C max

0.1

W

4188-839_issue 8_07/14_pt1_EN/BS new Repeat_inst

1

Data and installation

Vigilon Repeat panel (EN/BS)

VIG-RPT-72

by Honeywell

Vigilon Fire System

GENT 2010

Panel healthy

15:45

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание GENT VIG-RPT-72

Страница 1: ...o 45ºC Relative humidity Non condensing Up to 90 temperature 5 C to 45 C Battery 12V 7Ah sealed lead acid Mains operating voltage 230V 15 10 50 60Hz Rated Current 0 2A Emission BS EN61000 6 3 2001 Immunity BS EN50130 4 1996 Part 4 LVD BS EN 60950 2006 Ingress protection IP31 estimated Colour Door Pantone 422 Back box Graphite Grey RAL 7024 Controls with door closed Access level 1 Next and Previous...

Страница 2: ...o terminal block P9 on the Master Repeat Card fit battery lead supplied in the spares to connector P5 on Master Repeat Card connect the loop cables to terminal block P16 on the Master Repeat Card connect the 40 way ribbon cable to the Master Repeat Card connector P2 and the other end to Display Key Card on the top right edge connector P1 connect the 20 way ribbon cable to the Master Repeat Card co...

Страница 3: ...e Loop COM Master Repeat Card 01 L1 02 L2 0C LC P9 L N N P17 DANGER BT BT RS485 0V 24V WRITE PROTECT BUZZER DISABLE P8 DANGER DO NOT REMOVE L N P5 FS2 FS4 P16 P4 P2 P1 SW3 PB2 WD1 P14 P7 USB FS3 2A QB RESET DANGER WARNING Removal of cover exposes live parts mains electrical supply Loop OUT Previous Next Spur Connection XXXXX Fire Alarm System GENT 2007 Designed to EN54 Pt 2 4 Panel healthy 15 45 1...

Страница 4: ...control buttons must always be left in an enabled state with the control buttons link fitted At the end of their useful life the packaging product and batteries should be disposed of via a suitable recycling centre and in accordance with national or local legislation Do not dispose of with your normal household waste Do not burn WEEE Directive At the end of their useful life the packaging product ...

Страница 5: ...r sounds Cancel the buzzer using the local Cancel buzzer button Test functions When operating the SOUND ALARMS button it will activate the alarm sounders in the system Display test to ensure all LEDs are working Sound Alarms Silence Alarms Display of Fire events Reset Operation of U1 U4 Function keys as configured at the control panel Verify as configured at the control panel 4188 839_issue 7_08 1...

Страница 6: ...configuration of the system To create or change an existing Engineer PIN You will need to be at Access level 3 if an Engineer PIN is already set up Press the Menu On Off button and select Test Eng UserCode then momentarily press etc to select Config New Pass and then type a new PIN or change an existing PIN and press the Enter key will appear if a PIN is already setup It is recommended that the PI...

Страница 7: ...ith Mk4 MRC Menu map Control E C Q Key E Enter C Cancel Q Quit Verify etc Params 0 3 E C Q Timeslot etc Params 1 16 Delay On Params HH MM SS On E C Q Off Off DelayBlk Params 1 16 Delayed E C Q Params MM SS 0 10min End E C Q Stop Group EN BS EN BS Option for BS Repeat panel only Option for EN Repeat panel only Sector Build Params 1 255 E C Q Aux Rly Params 1 2 E C Q Params 1 32 E C Q Enable Disable...

Страница 8: ... Params 0 100 Signal C Q E Params 16 100 C Q E Params 0 255 Params 1 100 C Q E etc State enable Params 1 8 Params 0 15 C Q E Params 0 15 State disable TimeBlok etc Voice Tone number Set Up Loop Params 1 207 Device It is important to back up the data at the main control panel following any changes using the in Setup menus at the repeat panel Menus accessible with panel door open and AL2 password Ac...

Страница 9: ...8 C Q E N C P R 1 100 Loop Params 1 207 E Params 0 15 Q C E E Params C Q 1 207 Loop Params Fault Disable Exceptions Sub Faults HistFire etc etc Warning Device 1 4 1 32 Params Loop Params 1 255 E C Params Q MCP IO Line Device Device Sector Card etc Params 1 207 C Q E 1 8 Device Params Q E etc Active Historic Events Label UserCode TimeAvg Status etc Loop Map Control Set Up Info Test Eng EN BS Repeat...

Отзывы: