Honeywell Fire-Lite Alarms MMF-302-6 Скачать руководство пользователя страница 2

INCLuDED:  

(5) 1 x 4 Terminal Blocks    (2) 11/4˝ Stand offs       (3) Shunts

 

 

 

(4) Machine Screws   (2) Nuts     (1) Long Power Supply Jumper

(6) 3.9k Ohm 

End of Line Resistors

Shipped on Board:

(2) Shunts in Class A/B position

     (Shipped in Class B position, remove shunts for Class A)

COMPATIBILITy REQuIREMENTS

To ensure proper operation, this module shall be connected to a compatible 
Fire•Lite system control panel (list available from Fire•Lite). Contact System 

Sensor for a current list of compatible detectors. 

COMPONENTS

Following  are  descriptions  of  the  MMF-302-6  mounting  frameworks.    There 
are two mounting options for MMF-302-6 modules:

 Up  to  six  MMF-302-6  modules  can  be  installed  on  a  CH-6  in  a  BB-6 

• 

cabinet

 One or two MMF-302-6 modules can be installed in a BB-2 cabinet

• 

Chassis 

The CH-6 chassis is used to mount MMF-302-6 modules in a BB-6 cabinet. It 

accommodates  up  to  six  MMF-302-6  modules  in  a  single  cabinet  row  three 
modules wide and two modules deep.

FIGuRE 1. Ch-6 ChASSIS:

The  BB-2  cabinet  has  a  built-in  chassis  that  will  accommodate  one  or  two 
MMF-302-6 modules.

FIGuRE 2. BB-2 CABINET:

0

1

2 3 4 5 6

7

8

9

0

7

8

6

5

4

3

2

1

9

10

11

12

13

14

15

BASE 

ADDRESS

ADDRESS

DISABLE

0

1

2 3 4 5 6

7

8

9

0

7

8

6

5

4

3

2

1

9

10

11

12

13

14

15

BASE 

ADDRESS

ADDRESS

DISABLE

The front MMF-302-6 module positions of each chassis are offset below the rear 

MMF-302-6 module positions so that all of the status indicators are visible.

Cabinets

A BB-6 will house the CH-6 chassis with up to six MMF-302-6 modules in

-

stalled on it. Refer to cabinet installation documents for dimensions.

The BB-2 cabinet houses one or two MMF-302-6 modules on the internal chas-
sis  that  is  part  of  the  cabinet.    Refer  to  cabinet  installation  documents  for 
dimensions. 

C0235-00

INSTALLATION STEPS

1.  Cabinet Mounting
 

 In a clean, dry area, mount the backbox using the four holes provided in 
the back surface of the cabinet (Figure 3).

2. Chassis Installation
 

 The CH-6 chassis is mounted in the BB-6 cabinet. It is attached to the 
two PEM studs on the back wall of the cabinet with two 8-32 hex nuts. 
The hex nuts are included with the chassis (Figure 4).

FIGuRE 3. TyPICAL MOuNTING hOLE LOCATIONS:

       

BACKBOX
MOUNTING
HOLES

FIGuRE 4. MOuNTING ThE Ch-6 ChASSIS:

Mount with hex nuts to PEM studs  

on back of cabinet

The BB-2 cabinet comes with the chassis already installed, so no mounting 
is necessary.

3. Module Installation
 

 There are two methods for installing a module in the rear position of a 

chassis. Method one is for installation of a rear module only, when no 

module will be installed in front of it. Refer to Figure 5 for instructions. 
Method two is for installation of a rear module when another module 
will be installed in the chassis position in front of it.  Refer to Figures 6a 

and 6b for method two. All necessary screws and standoffs are supplied 

with the modules.

FIGuRE 5. INSTALLATION OF REAR MODuLE ONLy, METhOD ONE:

2

3

1

Step 1: 

 Insert  the  bottom  of  the  MMF-302-6  module  down  into  a  
rear slot on the chassis. 

Step 2: 

 Carefully swing the upper edge of the board back towards the back 

of the chassis until it touches the two standoffs.

Step 3: 

 Align two 4-40 screws with the two standoffs and tighten.

Step 4:    Address and wire the modules according to the instructions in this 

manual.

F200-22-00 

I56-1900-005

C0206-00

C0235-00

C0239-00

C0237-00

firealarmresources.com

Содержание Fire-Lite Alarms MMF-302-6

Страница 1: ...451 A SYSTEM SENSOR B401 20 1100 A SYSTEM SENSOR N A 20 1400 A SYSTEM SENSOR N A 20 2100AT A SYSTEM SENSOR N A 20 2100B A SYSTEM SENSOR N A 20 2100D A SYSTEM SENSOR N A 20 2100S A SYSTEM SENSOR N A 20 2100TB A SYSTEM SENSOR N A 20 2100TD A SYSTEM SENSOR N A 20 2100TS A SYSTEM SENSOR N A 20 2300B A SYSTEM SENSOR N A 20 2300TB A SYSTEM SENSOR N A 20 2400 A SYSTEM SENSOR N A 20 2400TH A SYSTEM SENSOR...

Страница 2: ...The BB 2 cabinet houses one or two MMF 302 6 modules on the internal chas sis that is part of the cabinet Refer to cabinet installation documents for dimensions C0235 00 INSTALLATION STEPS 1 Cabinet Mounting In a clean dry area mount the backbox using the four holes provided in the back surface of the cabinet Figure 3 2 Chassis Installation The CH 6 chassis is mounted in the BB 6 cabinet It is att...

Страница 3: ... All external power supplies and detectors must be UL listed for fire protection signaling applications PROGRAMMING The MMF 302 6 module operates with the following Fire Alarm Control Pan els MS 9200 MS 9600 The modules are programmed as devices in each system according to the pro gramming instructions in the appropriate FACP manual F200 22 00 3 I56 1900 005 The steps in Figures 6a and 6b describe...

Страница 4: ...ove the two shunts from the A B select positions 2 To use a common power supply between multiple MMF 302 6 modules connect a long power supply jumper from T5 or T6 to T5 or T6 on the adjacent MMF 302 6 module 0 1 2 3 4 5 6 7 8 9 BASE ADDRESS TO NEXT DEVICE STATUS INDICATORS IN OUT 0 1 2 3 4 5 IDC ADDRESS IDC ADDRESS IDC ADDRESS SLC FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE...

Страница 5: ...his equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential in stallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harm...

Отзывы: