MU1H-1150GE23 R0808
6
Honeywell GmbH
GB
1. Safety Guidelines
1. Follow the installation instructions.
2. Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the
applications detailed in these installation instruc-
tions. Any other use will not be considered to comply
with requirements and would invalidate the
warranty.
4. Please take note that any assembly, commis-
sioning, servicing and adjustment work may only be
carried out by authorized persons.
5. Immediately rectify any malfunctions which may
influence safety.
6. Make sure that the filter is neither exposed to to low
nor to high temperatures.
7. It is necessary during installation to observe codes
of good practice, to comply with local requirements
and to follow the installation instructions.
2. Functional description
Water flows through both the prefilter and the fine filter
mesh from outside to inside and these traps dirt
particles on the outer face of the filter. For reasons of
hygiene, the fine filter insert must be replaced at no
longer than six monthly intervals. The washable
prefilter should be replaced at least after 2 years or
after the third rinsing.
Activated Carbon cartridge filters out fine particles,
eliminates of unpleasant odours and flavours caused
by chlorine or other organic substances, removes of
pesticides, insecticides, chlorinate solvents.
Average life-span of activated carbon cartridges: about
6 months.
3. Application
4. Technical data
5. Scope of delivery
The filters comprise:
• Simplex housing for 100µm sieve, followed by
duplex housing for 25µm sieve and activated
carbon cardridge
• Clear filter bowl
• Preliminary filter 100µm (rinsable)
• Fine filter 25 µm
• Activated Carbon insert
• ¾" female thread
• ¾"-1" adapter
• ¾"-¾" adapter
• Teflon-sealing tape
• Ring wrench for filter bowl
6. Options
7. Assembly
7.1 Installations Guidelines
• Install in horizontal pipework with filter bowl down-
wards
o This position ensures optimum filter efficiency
• Install shutoff valves before and after the filter
• Ensure good access
o Degree of contamination can be seen with clear
filter bowl
o Simplifies maintenance and inspection
• The installation location should be protected against
frost
• Do not install in places where there is strong
sunlight
7.2 Assembly instructions
1. Thoroughly flush pipework
2. Install filter
• Note flow direction (indicated by arrow)
o Install without tension or bending stresses
3. The appliance is ready for use
Medium
Water
Installation position
Horizontal with filter bowl
downwards
Operating pressure
Maximum 6.0 bar
Operating temperature Maximum 45 °C
Connection size
3
/
4
" female,
3
/
4
" male with
3
/
4
"-
3
/
4
" adapter
1" with
3
/
4
"-1" adapter
FF60 Triplex water filter: prefilter mesh size 100µm,
fine filter mesh size 25µm combined with acti-
vated carbon filter
Содержание FF60
Страница 15: ...MU1H 1150GE23 R0808 15 Honeywell GmbH NL ...