Honeywell FBII OMNI 400 Скачать руководство пользователя страница 32

ONE YEAR LIMITED WARRANTY 

 

Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 165 Eileen 
Way, Syosset, New York 11791, warrants its security equipment (the "product") to be free from defects in 
materials and workmanship for one year from date of original purchase, under normal use and service. Seller's 
obligation is limited to repairing or replacing, at its option, free of charge for parts, labor, or transportation, any 
product proven to be defective in materials or workmanship under normal use and service. Seller shall have no 
obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by 
anyone other than the Seller. In case of defect, contact the security professional who installed and maintains 
your security equipment or the Seller for product repair. 
This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE ARE 
NO EXPRESS WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED 
WARRANTIES, OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS 
PRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A 
PARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR 
FROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, IN-
CLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE 
BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL SELLER 
BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF 
THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY 
WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE 
OR FAULT. Some states do not allow limitation on how long an implied warranty lasts or the exclusion or 
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
Seller does not represent that the product may not be compromised or circumvented; that the product will 
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all 
cases provide adequate warning or protection. Buyer understands that a properly installed and maintained 
alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, 
but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property 
loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, 
PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARN-
ING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS 
OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE 
OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE 
OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
No increase or alteration, written or verbal, to this warranty is authorized. 

 

165 Eileen Way, Syosset, New York 11791

Copyright © 2004 Honeywell International Inc.

www.honeywell.com/security

 

ÊN9939V54Š 

N9939V5  4/04  Rev. A 

Содержание FBII OMNI 400

Страница 1: ...II Security System FBII Security System FBII Security System FBII Security System O OM MN NI I 4 40 00 0 O OM MN NI I 6 60 00 0 O OM MN NI I 6 62 24 4 O OM MN NI I 8 84 48 8 User Guide N9939V5 4 04 Rev A ...

Страница 2: ...EOUS COMMANDS 16 USING A PAGER 22 TESTING THE SYSTEM 24 RECOMMENDATIONS ON SMOKE DETECTORS 25 EMERGENCY EVACUATION 26 GLOSSARY 27 RADIO FREQUENCY EMISSIONS STATEMENTS 29 TELEPHONE MODEM INTERFACE STATEMENTS 29 TELEPHONE OPERATIONAL PROBLEMS 30 0560 DECLARATION OF CONFORMITY 30 LIMITATIONS OF THIS ALARM SYSTEM 31 ONE YEAR LIMITED WARRANTY 32 ...

Страница 3: ...ser code The ARMED light will go out TO ARM THE SYSTEM AND STAY INSIDE 1 Check to make sure the system is ready The Green READY light is lit 2 Press STAY 3 Enter your 4 digit or 6 digit user code The ARMED light and STAY light will both light REMEMBER Unless the Quick Exit feature is enabled you must disarm the system if you want to open the door or leave the premises after the exit time has passe...

Страница 4: ...2 54 Set Auto Arm Time of Current Partition OMNI624 848 or System OMNI400 600 All keypads By partition OMNI624 848 or system OMNI400 600 may also require code 55 Display Firmware Version LCD only Displays panel s revision 56 Display Key Fob Low Batteries OMNI624 848 only All keypads Wireless Key Fob battery test 57 Door Strike All keypads Activate doorstrike or trigger May require certain user cod...

Страница 5: ...le Zone Alarm Zone Bypass 3 Zone Fault Zone Trouble Zone Alarm Zone Bypass 4 Zone Fault Zone Trouble Zone Alarm Zone Bypass 5 Zone Fault Zone Trouble Zone Alarm Zone Bypass 6 Zone Fault Zone Trouble Zone Alarm Zone Bypass 7 Zone Fault Zone Trouble Zone Alarm Zone Bypass 8 Zone Fault Zone Trouble Zone Alarm Zone Bypass STAY Stay Armed INST Instant Armed Arm disabled TRBL Phone Fail SUPER Bell Supr ...

Страница 6: ...pes of keypads that can be used with this system LCD keypad alpha display Fixed Word keypad 2 digit display or LED keypad Since your system may use any of these keypads the displays of all keypads are described in this manual The OMNI400 OMNI600 OMNI624 and OMNI848 are listed by Underwriters Laboratories for Household Fire and Burglary applications Throughout this manual the following conventions ...

Страница 7: ...on 1 25 2 26 3 27 4 28 5 29 6 30 7 31 8 32 9 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46 23 47 24 48 Zones 9 through 48 are not used with the OMNI400 Zones 13 through 48 are not used with the OMNI600 Zones 25 through 48 are not used with the OMNI624 Entry time ________ Door __________ Exit time ________ Entry time ________ Door __________ Exit time is the same ...

Страница 8: ...w you how to activate these emergency keys The emergency keys used for all keypads are shown below The following SEND HELP ALERT is programmed into my system KEYS DESCRIPTION T 7 9 1 3 NOTE These key combinations may also be programmed for other system functions PAGER ALERT If programmed a button on a designated keyfob may also be used to send an alert message to a pager Ask your installer if this...

Страница 9: ...53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 32 64 User Codes 16 through 64 are not used with the OMNI400 or OMNI600 User Codes 33 through 64 are not used with the OMNI624 ____ ____ USER CODE NOTE User codes can be either 4 digits or 6 digits depending on installer 4 digit 6 digit programming Ask your installer what type of user codes 4 or 6 digits are being used in your system W...

Страница 10: ...m has this feature and if so if it causes an alarm or zone bypass TO ARM THE SYSTEM AND LEAVE Enter your user code The System ARMED light will go on and the display will show LCD Keypad ON AWAY 120s Fixed Word Keypad ARM LED lit 120 LED Keypad ARM LED lit NOTE The number 120 shown above for the LCD and Fixed Word keypads indicates a counter that is updated every second and displays the amount of t...

Страница 11: ...nd arm the system normally If the problem cannot be resolved you may bypass the zone that is not ready Bypassing should only be done if the problem on the zone cannot be resolved OR if you intentionally wish to leave the zone disarmed For example you would leave the zone disarmed if you plan to keep the window open for ventilation Zones that are bypassed are not protected when the system is armed ...

Страница 12: ...Word Keypad INSTANT LED Keypad ARM and INSTANT LED lit TO ARM THE SYSTEM IN INSTANT MODE AND STAY INSIDE In INSTANT STAY mode the perimeter portion of your burglar alarm system is armed but the time delays are eliminated from your normal entry exit door s All interior protection is disarmed so you are free to move around inside Check to make sure the system is READY When it is ready press INSTANT ...

Страница 13: ... After the bypass command has been accepted the keypad sounds one long beep and the following is displayed LCD Keypad BYPASSED ZN 01 FRONT DOOR Fixed Word Keypad BYPASS Zone number displayed LED Keypad Zone LEDs of the zone s bypassed slowly blink To Bypass multiple zones within 10 seconds of the BYPASS User Code Zone No entry enter BYPASS Zone No This command can be repeated for each zone to be b...

Страница 14: ... Glass Keypad READY LED lit LED Keypad READY LED lit If alarms occurred when the system was armed or if a trouble condition exists the display shows LCD Keypad ALM MEM ZN1 Fixed Glass Keypad ARM LED lit READY LED blinks LED Keypad zone LEDs Fast Blink alarm or tamper Slow Blink bypass Slow Pulse trouble problem with RF receiver or low battery Solid On zone faulted Burglary alarms will sound a stea...

Страница 15: ... other user codes all system functions 2 Secondary Master same as primary master except cannot change the primary master s code 3 User cannot assign codes and cannot bypass zones 4 Limited user same as level 3 except can disarm the system only if it was armed by another user with level 4 authority cannot disarm if armed by user of higher authority level ASSIGNING PARTITIONS TO USERS OMNI624 and OM...

Страница 16: ...s circumstance QUICK ARMING If programmed by your installer Quick Arming allows you to arm the system in the AWAY mode without entering a user code Press then 1 NOTES Disarming your system always requires a valid user code This system can be programmed by the installer for the AUTOSTAY feature which automatically bypasses interior zones if you arm the system and do not exit through a delay zone du...

Страница 17: ...k Exit restarts the exit delay time if the system is already armed This allows someone to leave after the system has been armed without having to disarm the system first To restart the exit delay time press STAY TURN CHIME ON OFF Chime is an optional feature that causes the keypad to beep when selected doors are opened while the burglary protection is off or disarmed Only your installer can progra...

Страница 18: ... Partition 3 is available on the OMNI848 ONLY SET AUTO ARM TIME Set Auto Arm Time lets you set the time your system will automatically arm To set the Auto On Time Press 5 4 user code hour 00 23 minute 00 59 The keypad will prompt you for the required entries TO VIEW AUTOARM TIME To view the autoarm time for the partition to which the keypad is assigned press 5 2 user code with authority level 1 or...

Страница 19: ...ur clock has been keeping the proper time respond to the crystal adjustment prompt by pressing 1 followed by 0 0 when the system prompts you for an adjustment value If the clock has not been keeping time correctly when the crystal adjustment prompt is displayed proceed as follows 1 Enter 0 Adjust down Clock fast or 1 Adjust up Clock slow The adjustment value prompt is displayed 2 Determine how far...

Страница 20: ...t Test 56 Exit Fixed Word Keypad AC FO TEST LED Keypad An acknowledgement tone is sounded When a keyfob button is pressed the system will provide a display indicating if the keyfob has a low battery condition The system exits this mode when the star T key is pressed KEYPAD BACKLIGHT TIMER If you are using an OMNI KP OMNI KP US OMNI LCD or OMNI LCD US keypad these keypads have a timer controlled ke...

Страница 21: ...until you hear a beep Press any key except the T key to toggle the sounder on or off 0 Sounder off 1 Sounder on Press the key to exit the sounder menu OMNI LCD or OMNI LCD US There are four modes available in the Sounder Menu They are as follows On Normal Sounder Keys all sounds on Key Only Key Clicks Fire Only Fire Sounder temporal sounder not supported by all systems Off No Sounds at all To use ...

Страница 22: ...f 124 If the system is programmed by your installer for Stay Arms Stay when the system is armed by pressing the STAY key it will be reported to the pager as user 001 If the system is programmed by your installer for Instant Arms Away when the system is armed by pressing the INSTANT key it will be reported to the pager as user 001 If the system is armed with a keyswitch programmable digits that wer...

Страница 23: ...ves your new pager number and nulls out the remaining locations An acknowledgement tone sounds To exit without saving changes press the T key to exit pager phone number programming An acknowledgement tone sounds to indicate pager number programming has been exited If you press the key without first pressing the key to save your new pager phone number the system exits the pager phone number program...

Страница 24: ...ished testing BATTERY TEST It is recommended that you test your battery once a month In order to test your backup standby battery the following procedure should be followed 1 Disconnect AC Power from the system 2 Observe that the AC indicator light on the keypad goes off 3 Activate your alarm by performing the above SYSTEM TEST Remember to contact your central station if your system is monitored 4...

Страница 25: ... vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you install heat or smoke detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basements and attached garages DINING KITCHEN BEDROOM BEDROOM BEDROOM BED...

Страница 26: ... 3 Sketch a floor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check you...

Страница 27: ...y into your premises The burglary protection can be armed and disarmed and programmed for special levels of access and notification BYPASS FEATURE The Bypass feature allows you to exclude a selected zone or zones from the burglar alarm protection BYPASS BUTTON A button on the keypad used to activate the Bypass feature CENTRAL STATION The signal monitoring center contacted by your security system o...

Страница 28: ...ors and carbon monoxide gas detectors SILENT CONDITION Most types of alarms and troubles alert you with the keypad sounder and the sirens horns or speakers located in your premises The intent is to advise you of the alarm or trouble and allow you to respond promptly The audible sounds also let an intruder know that he has been detected and will hopefully scare him away In some circumstances an aud...

Страница 29: ...s document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions ...

Страница 30: ...ositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface La terminaison d une interface téléphonique peut consister en une combinaison de quelques dispositifs à la seule condition que la somme d indices d équivalence de la sonnerie de tous les dispositifs n excède pas 5 TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems disconnect...

Страница 31: ...ation Manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by the beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any m...

Страница 32: ...BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller does not r...

Отзывы: