HWLKS-C-M-1918
Honeywell
- 17 -
1.3 SCAN (
MENU
=> FUNCTION =>
SCAN or Shortcut: SCAN)
SCAN MENU 01/08
SCAN 01 : AUTOSCAN01
SPEED : 1~8/SLW/MID
START : 127.1, 027.0 zoom
END : 157.7, 080.7 zoom
DIR. : CCW (PAN:000.0)
SWAP : OFF
SAVE AND EXIT
Follow the steps below to program
Scans
.
1.Press the
SCAN
key to enter Auto Scan menu directly.
(
or
MENU
=> FUNCTION => SCAN)
.
2.Select an Auto Scan number by pushing the
Joystick
left or right.
3.Twist the
Joystick
to enter the title by scrolling through the alphanumeric characters and
pushing the handle to the right or left to move to the next space. Press
ENTR
key or push the
Joystick
down to finish title mode.
4.Push the
Joystick
downward to select “SPEED” and set the speed by twisting the
Joystick
clockwise or counterclockwise or moving the
Joystick
left/ right to select the auto scan speed.
5.When finish entering the title, select “START ANGLE” with the
Joystick
. Hold down the
SHFT/PGM
key while selecting the start position using the
Joystick
. Current panning position will
be displayed. Release
SHFT/PGM
key to complete the selection of the start position.
(Or twist zoom
handle or hit zoom button to start PTZ control for view selection and hit the Focus button to stop.)
6.Push the
Joystick
downward to select “END ANGLE.” Hold down the
SHFT/PGM
key while
moving the Joystick to select the end position. The end position angle should be larger than start
position. Release the
SHFT/PGM
key to complete the selection of the end position.
(Or twist
zoom handle or hit zoom button to start PTZ control for view selection and hit the Focus button to
stop.)
7.Push the
Joystick
downward to select “DIR.” Set the scan direction by moving the
Joystick
left and right to select the auto scan direction.(CW or CCW)
SCAN01:AUTOSCAN01 ~ SCAN08:AUTOSCAN08
SPEED(MODE) : 1/ 2 / 3/ 4/ 5/ 6/ 7/ 8/ SLOW / MEDIUM
1: SLOWER
↔ 8 FASTER
SLW : smooth Diagonal Scan in slowest speed
MID : smooth Diagonal Scan in medium speed
Diagonal Scan shows moving path from start point to
end point including tilt and zoom simultaneously.
The Scan function supports up to 16 programmed section of angles at 8 programmable speeds
.
Program and Operation
Содержание EXPTZ-252A
Страница 38: ...HWLKS C M 1918 Honeywell 38 Optional Accessories EXPTZ WL EXPTZ CN Unit mm Unit mm ...
Страница 39: ...HWLKS C M 1918 Honeywell 39 Optional Accessories EXPTZ PL Unit mm EXPTZ SS ...
Страница 43: ...HWLKS C M 1918 Honeywell 43 Dimensions EXPTZ ...
Страница 44: ...HWLKS C M 1918 Honeywell 44 Dimensions EXWJ400 ...