background image

HP10 Parameter Options for UC1200PF 

min

10 

min

20 

min

PHOTOCELL

ENABLED

MOVEMENT 

DETECTOR

AUTOMATIC
OPERATION

MOVEMENT

DETECTOR

SEMI-AUTOMATIC

OPERATION

NOT

USED

POWER UP

ON

POWERUP

OFF

PHOTOCELL

DISABLED

min

ON

OFF

10 

min

20 

min

OFF DELAY

Add together to give required time.

All OFF = 10 secs 

(Switched-live R1)

PHOTOCELL 

MODE 

= ACTIVE

OFF DELAY

Add together to give required time.

All OFF = 10 secs 

(Volt-free R2)

24 Hr Cycle

*

No 24 Hr Cycle

PHOTOCELL 

MODE 

= PASSIVE

NOT

USED

* If controlling water, the

  photocell cannot be used.

Please  note  that  additional 
parameters  are  available  via 
the HP2000 Programmer.

2

1

3

4

5

6

7

8

9

10

11

12

Off Delay

The Off Delay may be set between 5 and 35 minutes.   A 10-second Off Delay is available for walk-testing the 
product. In a typical office environment a 20-minute Off Delay is usually satisfactory.  

Movement Detector Operation (Automatic / Semi-Automatic)

Where  absence  detection  is  required  (ie  the  user  manually  turns  lights  ON  if  required  but  lights  still  turn  off 
automatically once an area is vacated), semi-automatic operation can be set via the programmer. 

Power Up Setting (On/Off)

Set to ON the detector will automatically switch its outputs on when Mains is applied. If set to OFF, the detector will 
power up without turning its outputs on, wait for 30 seconds and THEN look for movement. Only if the area is 
occupied will the output switch on at this time. The detector must be set to Power Up ON when used in conjunction 
with semi-automatic operation.

Photocell Operation (Passive/Active/Disabled)

This detector has an in-built photocell. The photocell has three modes of operation - Passive, Active and Disabled. 
Its operational behaviour is governed by the setting chosen and by the values stored in the Upper and Lower 
thresholds (see diagram overleaf).

Passive

 - The photocell will inhibit turn-on of the controlled load if sufficient natural light is available. It will not turn 

the load off whilst an area is occupied

Active

 - The photocell will turn the controlled load on and off as required whilst natural light levels fluctuate during a 

period of occupancy. This mode of operation operates in conjunction with a passing cloud timer (PCT). The PCT is 
asymmetrical in operation - the load will be switched on immediately that the light level falls below the lower set 
point, however, the load switches off only if the light level exceeds the upper threshold 

continuously

 for a period 

equal to the Off Delay.

Disabled

 - The photocell has no effect.

24hr Cycle (Yes/No)

For use in ‘Washroom Mode’ only (see overleaf).  In this mode it is necessary to have a hygiene cycle (flush) if the 
area has been unoccupied for 24hrs.  Select this feature and the output will switch on for the duration of the Off 
Delay once every 24hrs if the area remains unoccupied. 

Commissioning

The units are supplied with factory default settings (Power-Up On, fully Automatic operation, a 20 minute Off Delay, 
no 24hr Cycle, Photocell Disabled).   Programme using an infrared programming tool.   Please note that the full 
range of parameters is accessible via the HP2000; the HP10 and HP18 offer different/limited programming options.  

Walk-test Mode 

Walk-test mode is used to check that the detector is operating as required.  The short off-delay enables the installer 
to check that lights are switching on when movements are made at the edge of the detection zone.  It is easier to 
carry out a walk-test when the photocell is not holding the lights off.
1. Change the Off Delay to 10 seconds using the HP10 or press ‘TEST’ (HP18) or ‘Utilities/Walk Test/OK’ (HP2000).

2.   Move around the area that is being controlled, stopping for 10 seconds to allow the lights to switch off, before 

moving and triggering the lights back on. Re-programme the desired Off Delay once testing is complete. Note: If 
the HP2000 or HP18 was used to engage ‘soft’ walk test mode as described above, the programmed Off Delay 
will be automatically restored after 5 minutes.

W4253F

Содержание Ex-Or UC1200PF

Страница 1: ...allation and Commissioning Instructions Note HP2000 or HP10 HP18 required for commissioning Please note that the HP10 and HP18 offer different limited programming options LightSpot Washroom Series UC1200PF ...

Страница 2: ...enoid valve must be plumbed into the water feed to the urinal header tank and connected to the detector using 230V cable Multiple UC1200PF Larger areas can be covered by connecting extra units in parallel The total load current must not exceed 6Amps in case only one unit is activated N E L Permanent or switched supply LIVE IN LIVE IN NEUTRAL NEUTRAL EARTH EARTH LIGHTING FAN OR VALVE LightSpot Ligh...

Страница 3: ...fficient natural light is available It will not turn the load off whilst an area is occupied Active The photocell will turn the controlled load on and off as required whilst natural light levels fluctuate during a period of occupancy This mode of operation operates in conjunction with a passing cloud timer PCT The PCT is asymmetrical in operation the load will be switched on immediately that the l...

Страница 4: ...the control of water for washroom management applications urinals In order to maintain good standards of hygiene the products feature a washroom mode 24hr Cycle that if enabled ensures that when urinals have not been used for 24 hours i e the controlled area has been unoccupied a hygiene flush occurs Please note that when controlling lighting and urinals it is not possible to have the photocell in...