Power up and bind a Radiator Controller
(HR80)
If you want to control the zone temperature with your
evohome
Controller (the
evohome
Controller needs to be located in that
zone) press YES, otherwise press NO and bind the sensor.
On the HR80, you need to bind the
sensor and actuator separately
1
Power up the Radiator Controller (see HR80 instructions)
To bind the sensor
2
On the evohome Controller press the green bind button
3
Turn release clips on each side of the Radiator
Controller to remove the bottom plate
4
On the underside of the Radiator Controller
press the recessed bind button
5
The Radiator Controller screen should briefly show
a flashing RF icon
then SYNC when successful.
The evohome Controller will also show if binding
was successful (if not go back and re-bind)
If you are NOT following
GUIDED CONFIGURATION
follow these steps on your
evohome
Controller display
first:
1. On the evohome
Controller press and
hold “Settings” for 3
seconds
2. Press the green tick
3. Press ADD ZONE
4. Press the zone you want
to add the controller to
5. Rename the zone if
required and/or press the
green tick
6. Press RADIATOR VALVE
evohome
Controller
4
SIDE VIEW
BOTTOM VIEW
Radiator Controller (HR80)
22
Step 3: Power up and bind devices
Содержание Evohome
Страница 1: ...evohome Installation Guide ...
Страница 14: ...12 Step 2 Set up your Central Controller ...
Страница 38: ...36 Step 4 System test ...