4

Fig. 6. CT500 wallplate wiring connections.

Fig. 7. CT500 methods for wiring connection.

5 MOUNT THERMOSTAT TO 

WALLPLATE

Align the tab and connector pins at the top of the 
thermostat with the wallplate. See Fig. 8. 

Fig. 8. Mounting thermostat to wallplate.

Press the thermostat straight onto the wallplate to 
latch.

NOTE: To remove the thermostat from the wallplate, 

grasp the thermostat on both sides and pull it 
straight out.

Restore power to the heating/cooling system.

6 OPERATE YOUR THERMOSTAT

Display Temperature Setting

a. Press 

 or 

▲ 

once to display present temper-

ature setting.

b. The temperature setpoint and the room tem-

perature are shown separately on the digital 
display. The 

 indicator points to 

Set

 when the 

temperature setpoint is displayed and to 

Room 

when the room temperature is displayed.

7 SET FAN AND SYSTEM 

SWITCHES

Manually control fan and system settings using the 
switches located at the bottom of the thermostat case. 
See. Fig. 9 for switch locations.

M14874

ALTERNATE
MOUNTING
SCREW HOLE

MOUNTING
SCREW
HOLE

MOUNTING
SCREW HOLE

ALTERNATE MOUNTING
SCREW HOLE

KEEP WIRING IN
SHADED AREA

WIRING ENTRANCE HOLE

W

Y

G

R

M12537

FOR WRAPAROUND, STRIP 
7/16 IN. (11 mm)

FOR STRAIGHT INSERTION,
STRIP 5/16 IN. (8 mm)

M11025B

FAN

SYSTEM

Auto On

Cool Off Heat

DASHED LINES INDICATE TABS 
ON BACK OF THERMOSTAT

FAN

SYSTEM

Auto 

Cool Off Heat

ENGAGE TABS AT TOP 
OF THERMOSTAT WITH 
SLOTS ON WALLPLATE.

A

B

PRESS LOWER EDGE OF 
CASE TO LATCH.

Set

Room  

Set

Room  

Set

Room  

INDICATOR

ROOM TEMPERATURE

SETPOINT TEMPERATURE

M14679

Содержание CT500

Страница 1: ...If this control is replacing a control that contains mercury in a sealed tube do not place your old control in the trash Dispose of it properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control If you have questions call Honeywell at 1 800 458 1502 1 PREPARE FOR INSTALLATION Check Table 1 to be sure this thermostat is compa...

Страница 2: ...ly two wires they do not need labeling Wrap wires around a pencil to keep them from falling back into the wall as shown in Fig 2 Fig 2 Wrapping wires around pencil Replacing Clock With C or C1 Clock Terminals If you are replacing a Honeywell Chronotherm Thermostat you may find one or two wires that go to the C or C1 clock terminals on the Chronotherm Thermostat wiring wallplate Do not allow them t...

Страница 3: ...m and is adaptable to most 4 wire 18 to 30 Vac heating cooling systems Refer to Fig 4 and 5 for typical system wiring diagrams Fig 4 CT500 wiring diagram 4 wire heat cool system Fig 5 CT500 wiring diagram 2 wire heat only system IMPORTANT Use 18 gauge maximum wire to wire the ther mostat All wiring must comply with local electrical codes and ordinances If unsure about household wiring procedures c...

Страница 4: ...wn separately on the digital display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed 7 SET FAN AND SYSTEM SWITCHES Manually control fan and system settings using the switches located at the bottom of the thermostat case See Fig 9 for switch locations M14874 ALTERNATE MOUNTING SCREW HOLE MOUNTING SCREW HOLE MOUNTING SCREW HOL...

Страница 5: ...rate cooling system when outdoor temperature is below 50 F 10 C IMPORTANT Temporary protection delay protects compres sor the thermostat allows the compressor to remain off for five minutes before restarting Slide the System switch to Cool and the Fan switch to Auto Press the key to lower the temperature setting several degrees below the room temperature to start the cooling equipment Press the ke...

Страница 6: ...ol to C1 or C3 C1 Standard heating cooling temperature control C3 Agressive heating cooling temperature control can cause room temperature to overshoot the setpoint 9 Press the key again Factory information var ies by model is shown 10 Press the key to save all changes exit installer setup mode and return to normal operation NOTE After exiting installer setup mode slide the Sys tem switch to the d...

Страница 7: ...ostat section to exit this mode No display No power to thermostat Check power to thermostat Thermostat mounted incorrectly on wallplate See Mount Thermostat to Wallplate section Temperature display is incorrect Thermostat is configured for F or C Reconfigure the display See Customize Your Thermostat section for instructions to change the display Cannot change temperature setting The upper or lower...

Страница 8: ...as in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow ...