Honeywell ComfortPoint Open XFL5 Скачать руководство пользователя страница 4

XFL5 HARDWARE MIGRATION ADAPTER

Automation and Control Solutions

Honeywell International Inc.

1985 Douglas Drive North

Golden Valley, MN  55422

customer.honeywell.com

® U.S. Registered Trademark
© 2018 Honeywell International Inc.
MU1B-0074 IE10 R0518       M.S.  Rev. 05-18 
Part Number: CPO-XFL52XM
Printed in United States

3.

Insert the XFL5 Hardware Migration Adapter on the 
XSL513/XSL514 terminal block as shown in the fol-
lowing figure. Make sure that the XFL5 Hardware 
Migration Adapter is positioned correctly and apply 
firm pressure. 

4.

Lock the safety latch by moving the slider to the left 
on the XSL513/XSL514 terminal block as shown in 
Fig. 2 - Type A Safety Latch. If the XSL512 Manual 
Terminal Disconnect Module is installed, it is recom-
mended that you use a screwdriver or similar for 
locking as shown in Fig 3 - Type B Safety Latch.

Fig. 2. Type-A safety latch

Fig. 3. Type-B safety latch

5.

Insert the XF8xx/XFR8xx I/O module on the XFL5 
Hardware Migration Adapter.

6.

Make sure that the T-shape of the XF8xx/XFR8xx 
I/O module is aligned with T-slot of the XFL5 Hard-
ware Migration Adapter. This confirms that the 
XF8xx/XFR8xx I/O module has connected firmly 
with the XFL5 Hardware Migration Adapter.

XFL5 Hardware 
Migration Adapter

XSL513/XSL514 
Terminal Block

locking procedure

locked latch

locking procedure

locked latch

XF8xx/XFR8xx 
I/O module

Top Surface of T-Shape
on XF8xx/XFR8xx 
I/O module

Top Surface of T-Slot
on XFL5 Hardware 
Migration Adapter

Содержание ComfortPoint Open XFL5

Страница 1: ...egamenti a 230VCA devono essere eseguiti da personale qualificato S Denna instruktion skall förvaras tillsammans med regler eller anläggningsdokumentationen Elektrisk anslutning med 230 VAC får endast utföras av behörig personal DK Opbevar denne vejledning sammen med regler eller med anlægsdokumentationen Elektrisk tilslutning for 230 VAC bør kun foretages af autoriserede personer N Denne veiledni...

Страница 2: ...ve all safety latches present at the top of the terminal blocks in the following sequence a Rotate the safety latch in anti clockwise direction as shown in step a and b b c Remove the safety latch INSTALLATION WARNING Electrical Shock Hazard Can cause severe injury death or property damage Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage Mo...

Страница 3: ...ht and width increases by 29mm and 15mm respec tively ALL DIMENSIONS ARE IN MM 1 Refer to the notes See step 6 of the Removing XFL5xx I O Modules from XSL513 XSL514 terminal blocks section on page 2 for the module address of the XFL5xx I O module and adjust the rotary dial on the XFL5 Hardware Migration Adapter to set the address 2 Install the new safety latches between each terminal block as show...

Страница 4: ... shown in Fig 2 Type A Safety Latch If the XSL512 Manual Terminal Disconnect Module is installed it is recom mended that you use a screwdriver or similar for locking as shown in Fig 3 Type B Safety Latch Fig 2 Type A safety latch Fig 3 Type B safety latch 5 Insert the XF8xx XFR8xx I O module on the XFL5 Hardware Migration Adapter 6 Make sure that the T shape of the XF8xx XFR8xx I O module is align...

Отзывы: