Honeywell ComfortPoint Open XFL5 Скачать руководство пользователя страница 3

XFL5 HARDWARE MIGRATION ADAPTER

3

MU1B-0074 IE10 R0518

INSTALLING THE XFL5 HARDWARE MIGRATION ADAPTER

IMPORTANT NOTES

• Before starting the migration, refer to the notes (See step 3 of the “Removing XFL5xx I/O Modules from 

XSL513/XSL514 terminal blocks” section on page 2) that indicate the location of each type of XFL5xx I/O module. 
Select the precise XFL5 Hardware Migration Adapter and XF8xx/XFR8xx I/O module as described in Fig.1 and 
Table 1. 

Fig. 1. 

Table 1. 

• Migrating the XFL5xx LON I/O modules require additional space as after installing the XFL5 Hardware Migration 

Adapter and XF8xx/XFR8xx Panel Bus I/O module, the height and width increases by 29mm and 15mm respec-
tively. 

ALL DIMENSIONS ARE IN MM

1.

Refer to the notes (See step 6 of the “Removing 
XFL5xx I/O Modules from XSL513/XSL514 terminal 
blocks” section on page 2) for the module address of 
the XFL5xx I/O module and adjust the rotary dial on 
the XFL5 Hardware Migration Adapter to set the 
address. 

2.

Install the new safety latches between each terminal 
block as shown in the following figure.

B

A

Sl.

No.

XFL5xx 

I/O 

module 

type

ComfortPoint 

Open XFL5 

Hardware 

Migration Adapter 

Model Name (A)

XF8xx/XFR8xx 

I/O Module (B)

1

XFL521A

XFL521B

CPO-XFL521M

XF821A

2

XFL522A

XFL522B

CPO-XFL522M

XF822A/XFR822A

3

XFL523A

XFL523B

CPO-XFL523M

XF823A

4

XFL524A

XFL524B

CPO-XFL524M

XF824A/XFR824A

Before Migration 

After Migration 

B+15

B

A

(114.5)

(99.5)

(89)

A+29
(118)

Rotary dial

XFL5 Hardware Migration 
Adapter

Содержание ComfortPoint Open XFL5

Страница 1: ...egamenti a 230VCA devono essere eseguiti da personale qualificato S Denna instruktion skall förvaras tillsammans med regler eller anläggningsdokumentationen Elektrisk anslutning med 230 VAC får endast utföras av behörig personal DK Opbevar denne vejledning sammen med regler eller med anlægsdokumentationen Elektrisk tilslutning for 230 VAC bør kun foretages af autoriserede personer N Denne veiledni...

Страница 2: ...ve all safety latches present at the top of the terminal blocks in the following sequence a Rotate the safety latch in anti clockwise direction as shown in step a and b b c Remove the safety latch INSTALLATION WARNING Electrical Shock Hazard Can cause severe injury death or property damage Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage Mo...

Страница 3: ...ht and width increases by 29mm and 15mm respec tively ALL DIMENSIONS ARE IN MM 1 Refer to the notes See step 6 of the Removing XFL5xx I O Modules from XSL513 XSL514 terminal blocks section on page 2 for the module address of the XFL5xx I O module and adjust the rotary dial on the XFL5 Hardware Migration Adapter to set the address 2 Install the new safety latches between each terminal block as show...

Страница 4: ... shown in Fig 2 Type A Safety Latch If the XSL512 Manual Terminal Disconnect Module is installed it is recom mended that you use a screwdriver or similar for locking as shown in Fig 3 Type B Safety Latch Fig 2 Type A safety latch Fig 3 Type B safety latch 5 Insert the XF8xx XFR8xx I O module on the XFL5 Hardware Migration Adapter 6 Make sure that the T shape of the XF8xx XFR8xx I O module is align...

Отзывы: