HVAC System Support
Comfort Window supports most standard
HVAC systems on the market. The following
is a list of system types that Comfort Window
supports:
•
Standard 4-wire
Compressor/Furnace/Fan system
•
Standard 4-wire Compressor/Electric
Heat/Fan system
•
Single transformer, 2-stage Heat,
Compressor/Furnace/Fan system
•
Single transformer, 3-stage Heat,
Compressor/Furnace/Fan system
•
Double transformer (1 for Compressor,
1 for Heater), standard
Compressor/Furnace/Fan system
•
Double transformer (1 for Compressor,
1 for Heater), standard
Compressor/Furnace/Fan system, with
2-stage Heat
•
Double transformer (1 for Compressor,
1 for both Heating Units),
Compressor/Furnace/Fan system, with
2 separate Heating Units
•
Double transformer (1 for Compressor
and first Heating Unit, 1 for second
Heating Unit),
Compressor/Furnace/Fan system, with
2 separate Heating Units
•
Triple transformer (1 for Compressor, 1
for first Heating Unit, and 1 for second
Heating Unit),
Compressor/Furnace/Fan system, with
2 separate Heating Units
•
Heat Pump with Single Transformer
•
Heat Pump with Single Transformer,
with 2 Stages for the Compressor Cycle
(either for Heating or Cooling)
•
Heat Pump with Double transformer (1
for Heat Pump and 1 for secondary
Heating Unit), with 2 separate Heating
Units
•
Heat Pump with Double transformer (1
for Heat Pump and 1 for secondary
Heating Unit), with 2 separate Heating
Units, with 2-stages
*For a complete description of how to wire
each type of system supported by Comfort
Window, please refer to
Section V: Wiring
Guide
.
Equipment Controls
Comfort Window supports different settings
relating to Gas and Electric heaters, along with
settings for different actions for Heat Pump
change-over (B/O signal).
Gas heaters typically drive the system fan
during heating time periods, while Electric
Heaters or Heat Pumps typically expect the
thermostat to control the system fan during
heating. Comfort Window provides an option
to stop driving the system fan during heating
time periods to allow the Gas Heater to drive
the fan*. Alternatively, Comfort Window can
also be set up to drive the system fan during
heating time periods for Electric Heaters.
Comfort Window provides a setting to control
the change-over control signal (B/O) used in
Heat Pump systems. In certain heat pump
systems, the B/O signal energizes during
cooling while other systems expect that the
B/O signal will energize during heating.
Comfort Window is compatible with either type
of system. Simply navigate through the
settings icon to the Equipment Controls
settings page. Select the appropriate option in
each of the selections available.
17 of 24
*
*
*Caution!
Please note that it is very important to set up
your system properly – especially if you have an Electric
your system properly – especially if you have an Electric
Heater or if your Gas Heater does not drive the system fan
automatically. If Comfort Window is not set up to drive the
system fan and your system is of this type, it is possible that
your heater will overheat because no air is moving through it.