WWW.COMBISAFE.COM
9
1
- Reposition the guardrails to close
any side exits. Check that the M24
screws are tight in place. Attach the
crane hooks to the 2 lifting rings.
Detach the anchors.
2
- Move the Escalib. Pivot the Escalib
according to the height of the level
which needs to be accessed with 90°
rotations; Install 8 cm away from the
wall.
REQUIREMENTS:
> Fit new anchorages as new
modules are added.
> The dismantle must be done in
the reverse order of assembly.
3
- Positioning on the ground and
leveling the Escalib.
4
- Anchor the Escalib
before removing the
slings from the crane.
5
- At the access levels, the
guardrails are positioned so as to
privilege access by the main face A
(face names shown on the sticker).
6
- Check that the stair tower has
been anchored before unhooking
the slings. Guardrails must be
swung out of the way to allow
access to the required level.
30°
max.
LIFTING AND MOVING
(No more than 8 modules stacked)
WARNING:
Check that the ground on which the staircase Escalib is to be erected is able to withstand the load.
WARNING:
Comply with the general rules for handling and stability.
7
- Fill the Pre-Use Inspection Report