Installation Guide
9
4.5 Installer Parameters Table
4.5.1 Category 1 - Room Thermostat Settings
Note
1) Remember to always press the green button to confirm that you want to store your new Installer Set-
Up setting. To exit the Installer Mode press the
AUTO
or
MAN
button.
Parameter
Parameter
No.
Factory Default Setting
Optional Setting
Category 1 Parameters – Room Thermostat Settings
Display Description
Display Description
AM-PM / 24hr
Display
1:CL
12
12 hr – AM/PM clock
display format
24
24 hr clock display format
Reset Time/ Temp
Program
2:rP
1
Time / Temp profile
set to factory default
Changes to 0 when
one of the time/temp
profiles are changed
0
Time / Temperature are as
programmed
To restore the factory profile set to 1
Auto Summer/
Winter Time
Change
3:tC
1
Auto Summer/Winter
Time Change
Enabled
0
Auto Summer/Winter Time Change
Disabled
LCD Backlighting
5:bL
1
Backlighting Enable
0
Backlighting Disabled
Upper Temp Limit
6:uL
35
35°C Upper Temp.
Limit
21 to
34
21°C to 34°C adjustment in 1°C
steps
Lower Temp Limit
7:LL
5
5°C Lower Temp.
Limit
5 to 21
6°C to 21°C adjustment in 1°C steps
Optimisation
8:OP
0
Optimisation
Disabled
1
Optimisation Enabled
Temperature
Offset
12:tO
0
No temperature
offset
-3 to
+3
-3°C to +3°C adjustment in 0.1°C
steps
Proportional Band
Width
13:Pb
1.5
Proportional band of
1.5 degrees
1.6 to
3.0
1.6°C to 3.0°C adjustment in 0.1°C
steps
Scheduled
Maintenance Alert
Period (months)
19:SP
0
Scheduled
Maintenance Alert
Period disabled
0 to 48
0 to 48 months adjustment in 1
month steps
Reset Parameters
to Factory
Defaults
20:FS
1
All settings at factory
defaults
Changes to 0 when
one of the parameter
is changed
0
Settings are as modified above