Installation Guide

5

2.2.3 Locating the Room Thermostat

While still in the Test Mode, as described in section 

2.2.2

, the room thermostat should be located taking 

the following into consideration and reviewing the illustrations below:

1.

  Find a suitable location where the signal transmission is reliable. Reliable transmission is indicated when 

the relay box is flashing the green LED every 6 seconds. 

NOTE: 

The relay box relay will be off.

2. 

Install the room thermostat on the wall using the wall bracket as shown in the diagram below. 

3.

  Exit the Test Mode by pressing the 

AUTO

 or 

OFF

 button.

2.3 System Check

Now a simple test can be completed to check the full system has been installed correctly:

1.

  Press the 

OFF

 button.

2.

  Check the boiler supply is on and check that the green LED on the relay box is off.

3.

  Press the 

MAN

 button.

4.

  Adjust the setpoint up to the maximum (35°C) by pressing the     button. The boiler should come on 

(green LED 

ON

 on relay box) after a few seconds and the   symbol appears on the room thermostat 

LCD display.

5. 

Press the 

OFF

 button. The boiler will go off (green LED 

OFF

 on relay box) after a few seconds and the 

 symbol disappears.

6.

  Check the system operation by alternately pressing the 

MAN

 and 

OFF

 buttons several times, bearing 

in mind the switching delay referred to above.

Now, you should have completed the installation successfully - to begin operating at the default factory 

settings press the 

AUTO

 button or press 

PROG

 to modify the built-in heating program accordingly.

Wall bracket

• The room thermostat should be installed in an open space for best performance as it is a radio frequency device.

• Leave  at  least  30cm  distance  from  any  metal  objects  including  wall  boxes  and  at  least  1  metre  from  any  other 

electrical equipment eg. radio, TV, PC etc.

• Do not mount onto metal wall boxes.   •  It is recommended that the relay box is fully installed.

1.2m

Содержание CM721

Страница 1: ...roducts from individual system packs are separated or mixed with other pre configured system packs during installations please refer to section 5 1 Binding Rebinding Procedure to bind the desired units together and allow them to communicate with each other Table of Contents Section Page 1 Installation Information 2 2 Installing the CM700 Wireless System 3 2 1 Installing the Relay box 3 2 2 Install...

Страница 2: ... strength of the RF signal reaching the relay box depends on the number of walls and ceilings separating it from the room thermostat as well as the building construction the diagram below illustrates an example of typical signal strength reduction Walls and ceilings reinforced with steel or plasterboard walls lined with metal foil reduce the RF signal significantly more Once a position is selected...

Страница 3: ...iance considerations Keep AC mains supply load cables separate from signal wiring Refer to Code of Practice standards EN61000 5 1 and 2 for guidance NOTE The Relay Box contains no user serviceable parts It should be opened and installed by qualified installer only WARNING Electrostatic sensi tive device Do not touch the circuit board NOTE All wiring must be in accordance with IEE regulations CAUTI...

Страница 4: ...the green button to confirm c Press the or buttons to set the current year e g yr 07 2007 then press the green button to confirm The date is now stored d Use the or buttons to set the correct time then press the green button to confirm Each press of the buttons will change the time by one minute and holding them down will change the time slowly at first and get progressively quicker Note If this m...

Страница 5: ...djust the setpoint up to the maximum 35 C by pressing the button The boiler should come on green LED ON on relay box after a few seconds and the symbol appears on the room thermostat LCD display 5 Press the OFF button The boiler will go off green LED OFF on relay box after a few seconds and the symbol disappears 6 Check the system operation by alternately pressing the MAN and OFF buttons several t...

Страница 6: ...iod of 1 hour the red LED will illuminate to indicate that no RF messages have been received during the last hour The relay box will also enter the failsafe mode as selected in Installer Mode see section 4 2 BDR91 Relay box Fail Safe Mode Setup To allow manual control of the relay box output manual override is available in fail safe mode When RF communication is restored the relay box will automat...

Страница 7: ...o indicate the selected fail safe mode IMPORTANT To enable the frost protection when RF communication is lost select the fail safe mode 1 For systems with separate frost protection thermostat or where frost protection is not required select fail safe mode 0 1 Press the OFF button 2 Press and hold the button and the two PROGRAM and buttons together 3 The unit will display the first parameter of ins...

Страница 8: ...e preset period expires the CM721 CM727 will display the SERVICE icon Set parameter 19 SP to the required value to enable maintenance alert Value set to zero disables the function Summer Winter Auto time change This feature moves time automatically on the last Sunday of March and the last Sunday of October The feature is factory enabled To enable Set parameter 3 tC category 1 to 1 Temperature Offs...

Страница 9: ...1 Auto Summer Winter Time Change Enabled 0 Auto Summer Winter Time Change Disabled LCD Backlighting 5 bL 1 Backlighting Enable 0 Backlighting Disabled Upper Temp Limit 6 uL 35 35 C Upper Temp Limit 21 to 34 21 C to 34 C adjustment in 1 C steps Lower Temp Limit 7 LL 5 5 C Lower Temp Limit 5 to 21 6 C to 21 C adjustment in 1 C steps Optimisation 8 OP 0 Optimisation Disabled 1 Optimisation Enabled Te...

Страница 10: ...tton on the room thermostat Then press the and buttons together along with the button The unit will display InSt and CONTROL BINDING 5 Press the green button to send the binding signal out to the relay box The red LED is switched off to confirm successful binding operation If the red LED still flashes push the button again until binding is successful 6 Now go to Section 2 Installing the CM700 Wire...

Страница 11: ...correct or incomplete binding procedure Incorrect position of the room thermostat during binding Repeat the binding procedure Repeat the binding procedure keeping approx 1 m distance between the relay box and the room thermostat The red LED on the relay box is illuminated Communication loss The relay box receives no RF messages from the room thermostat RF signal is blocked due to wrong location of...

Страница 12: ...and by its Authorised Representative Honeywell International Inc Honeywell Control Systems Ltd Arlington Business Park Bracknell Berkshire RG12 1EB Technical Help Desk 08457 678999 www honeywelluk com Hereby Honeywell declares that this CM727 CM721 room thermostat and BDR91 Relay Box are in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC 2006 95 EC a...

Отзывы: