background image

11

Manufactured for and on behalf of the Environmental and Combustion Controls Division of 

Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its 

Authorised Representative Honeywell International Inc.

TROUBLESHOOTING THE CM707

Symptom

Remedy

Blank Display (Power Loss).

Check batteries are installed by removing the 

battery cover.

Check batteries have been installed in the 

correct orientation.

Replace the batteries.

Display shows flashing 

 

symbol.

The batteries in the thermostat are low on 

power - Replace the batteries.

Display shows 

 symbol.

A fault has occurred in your heating system. 

Remove and re-insert the batteries.

If the 

 symbol does not clear after a few 

minutes contact your installer.

Display shows the word 

SERVICE

Your  installer  has  set  a  scheduled 

maintenance  alert  period  on  your  CM707  as 

a  recommendation  that  your  heating  system 

should receive a routine inspection.

Call  your  installer  to  arrange  a  maintenance 

visit.

Note: 

The CM707 and heating system will 

continue to operate as normal.

Troubleshooting Guide

Содержание CM707

Страница 1: ...CM707 Programmable Room Thermostat with Optimum Start Optimum Stop and Delayed Start User Guide ...

Страница 2: ...sen and then leave it alone to do its job The best way to do this is to set low temperatures first say 18 C and then turn them up by one degree each day until you are comfortable with the temperatures You won t have to adjust the thermostat further Any adjustments above these settings will waste energy and cost you more money If your heating system is a boiler with radiators there will usually be ...

Страница 3: ... Batteries 4 STEP 2 Setting the Date and Time 5 STEP 3 Running the Built in Heating Program 5 PROGRAMMING THE CM707 The Built in Heating Program 6 Reviewing the Heating Program 6 Modifying the Heating Program 6 Disabling Enabling Time Periods 7 OPERATING THE CM707 Operating Modes 8 Temperature Enquiry Adjustment 8 Time Adjusting 8 Holiday Function 9 Special Features 9 TROUBLESHOOTING THE CM707 Tro...

Страница 4: ...move the battery cover by pressing down and sliding out c Insert the 2 x AA LR6 Alkaline Batteries supplied with the thermostat ensuring the correct orientation see Controls Layout above SETTING UP THE CM707 Controls Layout COPY DAY DATE DAY 1 4 AUTO OPT 1 2 3 4 5 6 7 AUTO MAN OFF PROGRAM CM707 LCD Screen Battery Low Indicator Time Display Burner On Indicator Day Indicator Temperature Display Temp...

Страница 5: ...rrent year e g yr 13 2013 then press the green button to confirm The date is now stored and the Day Indicator will be displayed under the current day of the week e g 1 Monday 2 Tuesday etc d Use the or buttons to set the correct time then press the green button to confirm Each press of the buttons will change the time by one minute and holding them down will change the time slowly at first and get...

Страница 6: ... pushed forward 1 2 3 4 5 6 7 4 3 2 1 The Built in Heating Program The built in heating program has 4 temperature level changes per day that can be set between 3 00am and 2 50am the following day allowing you to maintain the evening temperature after midnight Each temperature level can be set between 5 C and 35 C and adjusted in 0 5 C increments The factory default program for heating is as follow...

Страница 7: ...es the day that is copied if the COPY DAY button is pressed again OR ii Press the DATE DAY button to move the day indicator to Tuesday Day 2 The program for that day can then be adjusted by following steps b to e Programs for the remaining days can be set in the same way using the DATE DAY button to move to the next day To exit the programming mode select the desired operating mode by pressing the...

Страница 8: ...e thermostat to control to a minimum temperature setting of 5 C default that acts as a frost protection measure for your home Temperature Enquiry Adjustment Temperature Enquiry In AUTO MAN and OFF operating modes the thermostat will display the current room temperature To review the programmed target temperature the temperature which the thermostat is trying to maintain press the button This targe...

Страница 9: ...umber of days that your home is vacant At midnight the holiday counter will be reduced by one until the selected number of days have passed The thermostat will then return to normal operation as set by the MAN or AUTO mode To cancel the HOLIDAY function or to exit the function at any time press the button a second time OPERATING THE CM707 Special Features Display Backlight The CM707 has a backlit ...

Страница 10: ...ed Start tick if enabled If you program your heating to come on early to allow it to heat up Delayed Start will save energy by delaying the start of the boiler a little depending on the difference between the programmed temperature and the actual room temperature When the two temperatures are close to one another the delay will be longer than when the they are further apart and in both cases will ...

Страница 11: ...Replace the batteries Display shows flashing symbol The batteries in the thermostat are low on power Replace the batteries Display shows symbol A fault has occurred in your heating system Remove and re insert the batteries If the symbol does not clear after a few minutes contact your installer Display shows the word SERVICE Your installer has set a scheduled maintenance alert period on your CM707 ...

Страница 12: ...42010938 017 AA 2013 Honeywell International Inc Honeywell Control Systems Ltd Skimped Hill Lane Bracknell Berkshire RG12 1EB Technical Help Desk 08457 678999 www honeywelluk com ...