Honeywell Chronotherm T4600 Скачать руководство пользователя страница 7

T4600 Chronotherm

 

®

 ELECTRONIC PROGRAMMABLE LINE VOLTAGE THERMOSTAT

68-0168—3

7

M4659

AUTO   MAN   TEMPOR   NIGHT   DAY

M4658

AUTO   MAN   TEMPOR   NIGHT   DAY

Su     Mo     Tu     We     Th     Fr     Sa

M4662

AUTO   MAN   TEMPOR 

M4653

AUTO   MAN  

AUTO

M4663

After programming the T4600, there is no need for further
adjustment during the heating season. During the summer,
use the AUTO and down (-) keys to lower and hold the
setpoint or turn off the power.

NOTE:

The battery life is shortened if the T4600 is
unpowered (with circuit breaker turned off) for long
periods of time.

Additional Questions? Call Honeywell Consumer Services:
1-800-468-1502, Monday-Friday, 7:00 a.m. to 5:30 p.m.,
Central Time.

CHECKOUT

When the thermostat is first powered or if the battery is
drained, the display shows all segments briefly:

Then it shows 00E for 15 seconds followed by a flashing
12:00 AM (midnight) to indicate that the thermostat needs to
be programmed. If the time of day program is not entered, the
thermostat controls to the default setpoint, 60

°

F (16

°

C). If the

ambient temperature is below freezing, the display does not
operate until the power supply warms up the thermostat to
the operating temperature. There will be a clicking from the
relay, indicating the thermostat is working even though the
display is not restored.

Check out the thermostat operation by simulating normal
operation as follows:

1. Press and hold the up (+) key to raise the setpoint

above the ambient room temperature, calling for heat.
The temperature degree symbol flashes and the
electric heater warms up.

2. Press and hold the down (-) key to lower the setpoint

below the ambient room temperature. The temperature
degree symbol stops flashing and the electric heater
starts to cool down.

3. To determine the appropriate setpoint, set the

temperature at 68

°

F (20

°

C). Let the system operate for

at least one hour and adjust the setting as necessary.

M4657

AUTO   MAN   TEMPOR   NIGHT   DAY

Su     Mo     Tu     We     Th     Fr     Sa

AM
PM

ACTIVITY

RESULT

DISPLAY

Set Cottage Programs:
CAUTION:
Before using the COTTAGE program, make
sure there are no water pipes along outside
walls, sealed in cabinets or installed in a
manner that can cause them to freeze when
the room temperature falls to 45°F (7°C).  

In the COTTAGE program, the thermostat sets
back to 45°F (7°C), which is preprogrammed
and not adjustable. The DAY setback program
does not operate in the cot0 mode. The
temperature is controlled at 45°F (7°C) from
the NIGHT setback time on Sunday to the
morning recovery time on the following
Saturday.

Press the up (+) and down (-) keys to select
the desired COTTAGE program.  

  

The display flashes cot0, indicating that the
day setback program will not operate.

Press the up (+) and down (-) keys to select
the desired COTTAGE program.

In the cot3 mode, the DAY setback program
operates on Friday, Saturday and Sunday. The
temperature is controlled at 45°F (7°C) from
the NIGHT setback time on Sunday to the
afternoon recovery time on the following
Friday.

After selecting the NORMAL or COTTAGE
program, press and release the PROG key to
enter the program.

The thermostat enters the programmed mode,
displays the room temperature and AUTO.  
The up arrow indicates the comfort period; the
down arrow indicates the economy period.

TEMPORARILY OVERRIDE THE
PROGRAM 
 
Press the up (+) and down (-) keys to
temporarily change the temperature setpoint.

The current setpoint is displayed on the first
press of the up or down key. The setpoint can
be changed by pressing the up or down keys
again. The display also flashes TEMPOR
(temporary). This temporary program override
changes back to AUTO operation when the
next program change occurs.  

PERMANENTLY OVERRIDE THE
PROGRAM 
 
Press and release the AUTO key.

MAN (manual) is displayed. The program
change remains in effect until the PROG or
AUTO key is pressed.

Содержание Chronotherm T4600

Страница 1: ...d status Attractive contemporary styling Temperature range selectable between 45 F to 80 F 7 C to 27 C Simple pushbutton programming Weekday weekend 5 2 programming for permanent home normal operation Optional unoccupied low limit setting for seasonal residence cottage operation Temporary temperature override Program override for seasonal temperature setback Permanent override for seasonal shutdow...

Страница 2: ...itions are changed TRADELINE Models TRADELINE models are selected and packaged to provide ease of stocking ease of handling and maximum replacement value TRADELINE Models Available T4600A Chronotherm Electronic Programmable Line Voltage Thermostat with spst switching makes heating circuit on temperature fall Features TRADELINE pack Temperature Ratings Operating Range 22 to 104 F 30 to 40 C Control...

Страница 3: ... AS REQUIRED SPECIAL SERVICE CO ALR SOLDERLESS CONNECTORS MUST BE USED WHEN CONNECTING ALUMINUM CONDUCTORS OTHERWISE A FIRE HAZARD CAN RESULT THERMOSTAT BREAKS HEATING CIRCUIT ON TEMPERATURE RISE THERMOSTAT IS DESIGNED TO BE USED WITH APPLIANCES EQUIPPED WITH A LIMIT CONTROL T4600A ELECTRONIC LINE VOLTAGE THERMOSTAT ELECTRIC HEATER BLACK BLACK M4788 Fig 2 T4600A Typical wiring connections PROG AUT...

Страница 4: ...ad per thermostat must not exceed 2500W 8 ft of baseboard heater 2 Disconnect power to the thermostat to prevent electrical shock or equipment damage All wiring must comply with local electrical codes and ordinances 3 Remove the T4600 cover at the top or bottom edge with a slotted screwdriver 4 Remove the old thermostat from the wall taking care not to damage the wiring insulation 5 Check the old ...

Страница 5: ...ramming by holding down the PROG key for four seconds or until the display shows the room temperature IMPORTANT The T4600 uses the time and day that was last in its memory as the basis for control Unexpected thermostat operation can occur when the clock is not set properly ACTIVITY RESULT DISPLAY SET THE TIME AND DAY Hours Press and release the PROG key The hour display flashes in the 12 hour AM P...

Страница 6: ...ease the PROG key to enter the time PROGRAM THE DAY SETBACK AND AFTERNOON RECOVERY TIMES Day Setback Press the up and down keys to select the desired day setback time The display flashes the DAY setback time Afternoon Recovery Press the up and down keys to select the desired afternoon recovery time The display flashes the afternoon recovery warm up time Press and release the PROG key to enter the ...

Страница 7: ... 20 C Let the system operate for at least one hour and adjust the setting as necessary M4657 AUTO MAN TEMPOR NIGHT DAY Su Mo Tu We Th Fr Sa AM PM ACTIVITY RESULT DISPLAY Set Cottage Programs CAUTION Before using the COTTAGE program make sure there are no water pipes along outside walls sealed in cabinets or installed in a manner that can cause them to freeze when the room temperature falls to 45 F...

Страница 8: ...rdon Baker Road North York Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome 68 0168 3 J S Rev 2 99 The electrical power industry of the U...