PROGRAM THE NIGHT SETBACK AND
MORNING RECOVERY TIMES
Night Setback:
Press the up (+) and down (-) keys to select
the desired night setback time.

The display flashes the NIGHT setback time.
The display shows the time in 10-minute
increments (eg, 10:10, 10:20, etc).

Press and release the PROG key to enter  
the time.

Morning Recovery:
Press the up (+) and down (-) keys to select
the desired morning recovery time.

The display flashes the morning
 recovery (warm-up) time.

Press and release the PROG key to enter  
the time.

PROGRAM THE DAY SETBACK AND
AFTERNOON RECOVERY TIMES
Day Setback:
Press the up (+) and down (-) keys to select
the desired day setback time.

The display flashes the DAY setback time.

Afternoon Recovery:
Press the up (+) and down (-) keys to select
the desired afternoon recovery time.

The display flashes the afternoon recovery
(warm-up) time.

Press and release the PROG key to enter  
the time.

SELECT PERMANENT HOME (NORMAL)
OR SEASONAL RESIDENCE (COTTAGE)
OPERATION
Press and release the AUTO key to switch
between the NORMAL and COTTAGE
modes of operation.

Using the COTTAGE program overrides the
NORMAL program.

Set Normal (5-2) Programs:
Press the up (+) and down (-) keys to
select the day setback for weekdays
or each day of the week.

The display flashes nor5. In the NORMAL
program, the setpoint can be set back each
day of the week (nor7), weekdays only (nor5),
or zero days (nor0). If the setpoint is nor0,
night setback is the only active program.

Содержание Chronotherm T4600

Страница 1: ...d status Attractive contemporary styling Temperature range selectable between 45 F to 80 F 7 C to 27 C Simple pushbutton programming Weekday weekend 5 2 programming for permanent home normal operation Optional unoccupied low limit setting for seasonal residence cottage operation Temporary temperature override Program override for seasonal temperature setback Permanent override for seasonal shutdow...

Страница 2: ...itions are changed TRADELINE Models TRADELINE models are selected and packaged to provide ease of stocking ease of handling and maximum replacement value TRADELINE Models Available T4600A Chronotherm Electronic Programmable Line Voltage Thermostat with spst switching makes heating circuit on temperature fall Features TRADELINE pack Temperature Ratings Operating Range 22 to 104 F 30 to 40 C Control...

Страница 3: ... AS REQUIRED SPECIAL SERVICE CO ALR SOLDERLESS CONNECTORS MUST BE USED WHEN CONNECTING ALUMINUM CONDUCTORS OTHERWISE A FIRE HAZARD CAN RESULT THERMOSTAT BREAKS HEATING CIRCUIT ON TEMPERATURE RISE THERMOSTAT IS DESIGNED TO BE USED WITH APPLIANCES EQUIPPED WITH A LIMIT CONTROL T4600A ELECTRONIC LINE VOLTAGE THERMOSTAT ELECTRIC HEATER BLACK BLACK M4788 Fig 2 T4600A Typical wiring connections PROG AUT...

Страница 4: ...ad per thermostat must not exceed 2500W 8 ft of baseboard heater 2 Disconnect power to the thermostat to prevent electrical shock or equipment damage All wiring must comply with local electrical codes and ordinances 3 Remove the T4600 cover at the top or bottom edge with a slotted screwdriver 4 Remove the old thermostat from the wall taking care not to damage the wiring insulation 5 Check the old ...

Страница 5: ...ramming by holding down the PROG key for four seconds or until the display shows the room temperature IMPORTANT The T4600 uses the time and day that was last in its memory as the basis for control Unexpected thermostat operation can occur when the clock is not set properly ACTIVITY RESULT DISPLAY SET THE TIME AND DAY Hours Press and release the PROG key The hour display flashes in the 12 hour AM P...

Страница 6: ...ease the PROG key to enter the time PROGRAM THE DAY SETBACK AND AFTERNOON RECOVERY TIMES Day Setback Press the up and down keys to select the desired day setback time The display flashes the DAY setback time Afternoon Recovery Press the up and down keys to select the desired afternoon recovery time The display flashes the afternoon recovery warm up time Press and release the PROG key to enter the ...

Страница 7: ... 20 C Let the system operate for at least one hour and adjust the setting as necessary M4657 AUTO MAN TEMPOR NIGHT DAY Su Mo Tu We Th Fr Sa AM PM ACTIVITY RESULT DISPLAY Set Cottage Programs CAUTION Before using the COTTAGE program make sure there are no water pipes along outside walls sealed in cabinets or installed in a manner that can cause them to freeze when the room temperature falls to 45 F...

Страница 8: ...rdon Baker Road North York Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome 68 0168 3 J S Rev 2 99 The electrical power industry of the U...

Отзывы: