Honeywell Chronotherm IV T8611G Скачать руководство пользователя страница 7

T8611G CHRONOTHERM

®

 IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

7

69-1406—1

Setting Current Day and Time

1.

Press Set Current Day/Time.

NOTE: On initial powerup or after an extended power 

loss, 1:00 pm flashes on the display until a key 
is pressed.

2.

Press Day until the current day is displayed.

NOTE: Sun=Sunday, Mon=Monday, 

Tue=Tuesday, Wed=Wednesday, 
Thu=Thursday, Fri=Friday, Sat=Saturday

.  

3.

Press Time 

 or Time 

 until the current time is  

displayed.

NOTE: Tapping the Set Current Day/Time changes the 

time in one-hour increments.

.

NOTE: If the current time is Daylight Savings Time, 

press Daylight Time until DST is displayed.

.

4.

Press Run Program.

INSTALLER SYSTEM-TEST

Use the Installer System Test to check the thermostat 
operation. Refer to Table 4 for a list of the available 
system-tests. 

CAUTION

Equipment Damage Hazard.  
Minimum compressor off-time is bypassed 
during INstaller System Test.

Avoid cycling compressor quickly.

To start the sytem-test:
Press and hold the increase 

 and decrease 

 keys at 

the same time until 10 appears. All segments of the 
display will be displayed before the 10 appears. See Fig. 
11 and 12.

Table 4. Tests Available In Installer System Test.

 

Fig. 11. Display of all LCD segments.

.

Fig. 12. Display of test number

Refer to Table 5 for the directions and results of the 
specific tests.

NOTE: Press Time 

 to advance to the next test and 

Time 

 to go back to the previous test. Press 

Run Program to exit the system test

M14619

Time

Set

 

Program

System

Fan

Run

Program

Hold

 

Temp

Set

 

Current

Day/Time

Set

 

Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Set

 

Day/Time

Mon

PM

M14620

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Day

Heat/Cool

Settings

Daylight

Time

Copy

Set Day/Time

PM

Tue

M14621

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Time

Heat/Cool

Settings

Daylight

Time

Copy

Set Day/Time

AM

Tue

M14622

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Daylight

Time

Copy

Set Day/Time

AM

DST

Tue

M14623

Time

Set Program

System

Fan

Run

Program

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Wake

Room

System

Fan

Heat

Auto

AM

DST

Tue

Test Number

System Test Description

10-19

Heating equipment can be turned 
on and off.

30-39

Cooling equipment can be turned on 
and off.

40-49

Fan equipment can be turned on 
and off.

60  0 to 60  19

Keyboard keys test.

70-79

Thermostat information including 
date code and software versions are 
displayed.

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

FFan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht

M14612

Содержание Chronotherm IV T8611G

Страница 1: ...out the product operation Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outsid...

Страница 2: ...kup of T8611G in a heat pump system Fig 4 Correct wiring technique Mounting Thermostat 1 Engage tabs at the top of the thermostat and wall plate See Fig 5 2 Press lower edge of case to close and latch NOTE To remove the thermostat from the wall first pull out at the bottom of the thermostat remove top last Fig 5 Mounting thermostat on wallplate 5 FEET 1 5 METERS YES NO NO NO M10106 WIRES THROUGH W...

Страница 3: ...stem fan On Fan operates continuously Auto Fan operates with equipment LED Indication Two LED indicators are located in the upper right of the thermostat They indicate when a Check or Fail signal is sent to the thermostat from the system See Fig 8 Fig 6 T8611G key locations and descriptions Fig 7 Thermostat System and Fan key locations Fig 8 LEDs location M14624 Time Set Program System Fan Run Pro...

Страница 4: ...e Installer Setup numbers backward press the Time key To exit the Installer Setup press Run Program Fig 9 Display of all LCD segments Fig 10 Display of Installer Setup number and setting IMPORTANT Only configurable numbers are shown on the device Example If thermostat does not have a system key Installer Setup Number 12 will not be displayed Review Table 3 factory settings and mark any desired cha...

Страница 5: ...al energized for reversing valve in heating Deadband 30 3 Heating and cooling setpoints can be set no closer than 3 F 1 5 C 4 thru 10 Heating and cooling setpoints can be set no closer than the chosen value 4 4 F 2 C 5 5 F 2 5 C 6 6 F 3 C 7 7 F 3 5 C 8 8 F 4 C 9 9 F 4 5 C 10 10 F 5 C Not Used 31 and 32 Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 M...

Страница 6: ... adjusts to 3 F higher than actual room temperature 1 Display adjusts to 1 F lower than actual room temperature 2 Display adjusts to 2 F lower than actual room temperature 3 Display adjusts to 3 F lower than actual room temperature Furnace Air Filter Timer 43 0 Off 1 2 3 4 1 10 days 2 30 days 3 60 days 4 120 days Times counted when heat cool or fan is running Humidifier Pad Monitor 44 0 Off 1 2 3 ...

Страница 7: ...test and Time to go back to the previous test Press Run Program to exit the system test M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Day Time Mon PM M14620 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Day Heat Cool Setting...

Страница 8: ...fan is also energized 12 Stage two heat comes on Stage one heat and system fan remain on 11 Stage two heat turns off 10 Stage one heat and system fan turn off Emergency Heating Equipment System Test Time 20 Change from heating to emergency heating equipment System Test 21 Emergency heat come on 20 Emergency heat turn off Cooling Equipment System Test Time 30 Change from heating or emergency heatin...

Страница 9: ...soft ware identification code Example 02 software ID code 2 4 Press the increase key again to display the soft ware revision number Example 001 Revision number 1 5 Press the increase key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the system test The system test times out after four minutes without any key presses CHECKOUT Outdoor T...

Страница 10: ...ot come on No power to the thermostat Check for 24 Vac between R and C terminals If missing 24 Vac check if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten an...

Страница 11: ...self test Outdoor tempera ture not displayeda Option not activated Enter Installer Setup number 24 and set to 1 Thermostat must have OT terminals and a C7089B1000 installed Outdoor temperature display is incorrecta Outdoor sensor is connected incorrectly Refer to C7089B1000 Installation Instructions and check wiring between the thermostat and sensor Wrong sensor Replace sensor with C7089B1000 Sens...

Страница 12: ...yourhome T8611G CHRONOTHERM IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z ...