T8611G CHRONOTHERM

®

 IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

69-1406—1

4

Temperature Settings

Refer to Table 2 for the default program. If the daytime 
energy savings period is not used, press the period key 
(Leave or Return) until the time is blank. The fan setting 
feature is available on select thermostat models. See 
Owner’s Guide, form number 69-0940, for complete 
instructions on changing the program.

Table 2. Default Program Settings.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings will not need to be changed. Review 
the factory settings in Table 2 and if no changes 
are necessary, go to the Installer System Test 
section.

The Installer Setup is used to customize the thermostat 
to specific systems. Some of the options include 
temperature display, changeover and outdoor 
temperature display. Installer Setup numbers are listed in 
Table 3. The table includes all the configuration options 
and the factory-settings for the T8611. 

A combination of key presses is required to use the 
Installer Setup feature:
— To enter the installer setup, press and hold the 

information   

i

   key with the increase 

 and   

decrease 

 keys until the first number is displayed. 

All display segments appear for approximately three 
seconds before the number is displayed. See Fig. 9 
and 10.

— To advance to the next Installer Setup, press the  

Time 

 key.

— To change a setting, use the increase 

 or decrease

 

▼ 

key.

— To scroll the Installer Setup numbers backward, press 

the Time 

 key.

— To exit the Installer Setup, press Run Program.

Fig. 9. Display of all LCD segments.

Fig. 10. Display of Installer Setup 

number and setting.

IMPORTANT

Only configurable numbers are shown on the 
device. Example: If thermostat does not have a 
system key, Installer Setup Number 12 will not 
be displayed. Review Table 3 factory-settings 
and mark any desired changes in the Actual 
Setting column. When Installer Setup is com-
plete, review the settings to confirm that they 
match the system.

Period

Time

Heat 

Setpoint

Cool 

Setpoint

Fan 

Setting

Wake

6:45 AM

20°C 
(68°F)

25°C 
(77°F)

Auto

Leave

8:45 AM

4.5°C 
(40°F)

37°C 
(99°F)

Auto

Return 5:00 PM

20°C 
(68°F)

25°C 
(77°F)

Auto

Sleep

10:00 PM 4.5°C 

(40°F)

37°C 
(99°F)

Auto

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

FFan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht

M14618

INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)

FACTORY SETTING OR OTHER 
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)

Table 3. Thermostat Installer Setup Options.

Select

Installer Setup 

Number (Press 

Time 

 key to 

change)

Factory Setting

Other Choices

(Press 

 or 

 key to change)

Actual 

Setting

Display

Description

Display

Description

Not Used.

1 thru 4

Heating cycle 
rate.

5

6

Stage 2

1, 6 or 9

1—1 cph
6—6 cph used for last stage 

of heat pump systems

9—9 cph used for electric 

heat

6 (Not used)

7

6

Emergency heat

3, 6 or 9

Not Used.

8 thru 11

System setting 
adjustment

12

1

Manual 

changeover

0 or 2

0—Auto changeover
2—Fixed auto changeover

Содержание Chronotherm IV T8611G

Страница 1: ...out the product operation Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outsid...

Страница 2: ...kup of T8611G in a heat pump system Fig 4 Correct wiring technique Mounting Thermostat 1 Engage tabs at the top of the thermostat and wall plate See Fig 5 2 Press lower edge of case to close and latch NOTE To remove the thermostat from the wall first pull out at the bottom of the thermostat remove top last Fig 5 Mounting thermostat on wallplate 5 FEET 1 5 METERS YES NO NO NO M10106 WIRES THROUGH W...

Страница 3: ...stem fan On Fan operates continuously Auto Fan operates with equipment LED Indication Two LED indicators are located in the upper right of the thermostat They indicate when a Check or Fail signal is sent to the thermostat from the system See Fig 8 Fig 6 T8611G key locations and descriptions Fig 7 Thermostat System and Fan key locations Fig 8 LEDs location M14624 Time Set Program System Fan Run Pro...

Страница 4: ...e Installer Setup numbers backward press the Time key To exit the Installer Setup press Run Program Fig 9 Display of all LCD segments Fig 10 Display of Installer Setup number and setting IMPORTANT Only configurable numbers are shown on the device Example If thermostat does not have a system key Installer Setup Number 12 will not be displayed Review Table 3 factory settings and mark any desired cha...

Страница 5: ...al energized for reversing valve in heating Deadband 30 3 Heating and cooling setpoints can be set no closer than 3 F 1 5 C 4 thru 10 Heating and cooling setpoints can be set no closer than the chosen value 4 4 F 2 C 5 5 F 2 5 C 6 6 F 3 C 7 7 F 3 5 C 8 8 F 4 C 9 9 F 4 5 C 10 10 F 5 C Not Used 31 and 32 Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 M...

Страница 6: ... adjusts to 3 F higher than actual room temperature 1 Display adjusts to 1 F lower than actual room temperature 2 Display adjusts to 2 F lower than actual room temperature 3 Display adjusts to 3 F lower than actual room temperature Furnace Air Filter Timer 43 0 Off 1 2 3 4 1 10 days 2 30 days 3 60 days 4 120 days Times counted when heat cool or fan is running Humidifier Pad Monitor 44 0 Off 1 2 3 ...

Страница 7: ...test and Time to go back to the previous test Press Run Program to exit the system test M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Day Time Mon PM M14620 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Day Heat Cool Setting...

Страница 8: ...fan is also energized 12 Stage two heat comes on Stage one heat and system fan remain on 11 Stage two heat turns off 10 Stage one heat and system fan turn off Emergency Heating Equipment System Test Time 20 Change from heating to emergency heating equipment System Test 21 Emergency heat come on 20 Emergency heat turn off Cooling Equipment System Test Time 30 Change from heating or emergency heatin...

Страница 9: ...soft ware identification code Example 02 software ID code 2 4 Press the increase key again to display the soft ware revision number Example 001 Revision number 1 5 Press the increase key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the system test The system test times out after four minutes without any key presses CHECKOUT Outdoor T...

Страница 10: ...ot come on No power to the thermostat Check for 24 Vac between R and C terminals If missing 24 Vac check if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten an...

Страница 11: ...self test Outdoor tempera ture not displayeda Option not activated Enter Installer Setup number 24 and set to 1 Thermostat must have OT terminals and a C7089B1000 installed Outdoor temperature display is incorrecta Outdoor sensor is connected incorrectly Refer to C7089B1000 Installation Instructions and check wiring between the thermostat and sensor Wrong sensor Replace sensor with C7089B1000 Sens...

Страница 12: ...yourhome T8611G CHRONOTHERM IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z ...

Отзывы: