T8602A,B,C,D AND TS8602A,C Chronotherm

 

®

 III FUEL SAVER THERMOSTATS

CAUTION

Disconnect power supply to prevent electrical
shock or equipment damage.

Location

Install thermostat and wallplate about 5 ft (1.5m) above the
floor in an area with good air circulation at room
temperature.

Do not install the thermostat where it can be affected by:

drafts or dead spots behind doors, in corners, or
under cabinets.

hot or cold air from ducts.

radiant heat from sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall,
behind the thermostat.

If Replacing An Existing Thermostat

Turn off power to the thermostat at the furnace or boiler. A
two-transformer system can require turning off two
switches or disconnects. Remove any existing wallplate or
subbase from the wall. Write down the letter or number on
each wiring terminal, as the wire is removed, to avoid
miswiring later.

If New Installation

Run cable to the hole in the selected wall location, and pull
about 3 in. (76 mm) of wire through the opening. Color-
coded, 18 gauge thermostat cable with at least one
conductor for each wiring terminal is recommended.

Push excess wire back into the hole, and plug the hole
with nonhardening caulk, putty or insulation to prevent
drafts from affecting the thermostat operation.

Mounting Wallplate

Remove thermostat from wallplate. See Fig. 1.

The wallplate does not require leveling for operation, but
for appearance only. The wallplate mounts directly onto
the wall with the screws included. Using the wallplate as a
template, with a pencil, mark two (of three) mounting
screw positions on the wallplate that fit the application. See
Fig. 2. Use a 3/16 in. bit to drill holes for the anchors.
Gently tap anchors into the holes until flush with the wall
surface. Thread wires through the center opening of the
wallplate. Mount the wallplate using the two screws
provided. Gently tighten the screws, level the top surface
of the wallplate, and then securely tighten the screws.

WIRES THROUGH
WALL OPENING

WALL 

WALL
ANCHORS
(2)

WALLPLATE

MOUNTING
HOLES (3)

MOUNTING
SCREWS (2)

USE TWO MOUNTING HOLES THAT
BEST FIT APPLICATION.

1

1

M2917

M2918

Fig. 1. Removing thermostat from wallplate.

Fig. 2. Mounting wallplate on wall.

Wiring

CAUTION

The TS8602A,C can only be used on 750 mV
heating applications. The TS8602A,C will not
function properly on 250 mV, 500 mV or 24 Vac
heating applications.

All wiring must comply with local electrical codes and
ordinances.

Disconnect power before wiring to prevent electrical shock
or equipment damage.

The shape of the terminal barrier permits insertion of
straight or conventional wraparound wiring connections.
Either method is acceptable.

Refer to Fig. 4 through 15 for typical wallplate and
thermostat hookups.

NOTE:

Keep all wiring restricted to the ribbed area
surrounding the terminals (Fig. 3) to assure
thermostat/wallplate contact.

For single transformer applications, jumper
terminals R and RC for proper operation.

Содержание Chronotherm III T8602A

Страница 1: ...ocal waste management authority for instructions regarding recycling and the proper disposal of your old control If you have any questions call Honeywell Inc at 1 800 468 1502 INSTALLATION When Installing This Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given on the product to make sure the product ...

Страница 2: ...late does not require leveling for operation but for appearance only The wallplate mounts directly onto the wall with the screws included Using the wallplate as a template with a pencil mark two of three mounting screw positions on the wallplate that fit the application See Fig 2 Use a 3 16 in bit to drill holes for the anchors Gently tap anchors into the holes until flush with the wall surface Th...

Страница 3: ...in an oil system L1 HOT L2 1 W R HEATING ONLY WALLPLATE 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED M2923 RESISTANCE HEATER SWITCH HEATER BLACK BLUE RED RED WHITE R841C BIMETAL SWITCH Fig 8 T8602A B heating only circuit in an electric baseboard or ceiling cable system Fig 3 Keep wiring restricted to the ribbed area surrounding terminals W MILLIVOLT HEATING ONLY WALL...

Страница 4: ...ION AIR BLOWER MOTOR COMBUSTION AIR BLOWER RELAY AIR PROVING SWITCH W R Fig 9 T8602A B heating only circuit in a Honeywell Intermittent Pilot Gas Burner Ignition System L1 HOT L2 1 C W Y R G W R W R W R W R ZONE 1 HEATING ONLY WALLPLATE ZONE 2 HEATING ONLY WALLPLATE ZONE 3 HEATING ONLY WALLPLATE ZONE 4 HEATING ONLY WALLPLATE 2 3 3 3 3 R8239A1052 R8222B1067 R8222B1067 R8222B1067 1 POWER SUPPLY PROV...

Страница 5: ... PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED PRIMARY CONTROL SUCH AS GAS VALVE OR ELECTRONIC IGNITION MODULE CURRENT DRAW FOR W OR Y PLUS G MUST BE LESS THAN 1 6A M2924 W G HEATING COOLING WALLPLATE R RC Y COOLING CONTACTOR FAN RELAY HEATING PRIMARY CONTROL L1 HOT L2 1 L1 HOT L2 1 1 2 3 3 2 3 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED PRIMARY CONTROL...

Страница 6: ...CTORY SETTING IN IN TIME TEMP DISPLAY 2A 2B 24 HR IN 12 HR o o C F OUT 1 2 TO 1 TURN OUT 1 2 TO 1 TURN IN RECOVERY SELECTION ADAPTIVE INTELLIGENT CONVENTIONAL 3A IN FACTORY SETTING OUT 1 2 TO 1 TURN M2082C 1 SCREWS 2A 2B AVAILABLE ON SOME MODELS ONLY 2 SWITCH 4A FOR FAN OPERATION SELECTION AVAILABLE ON SOME MODELS ONLY 1 3A 1A 1B 2A 2B 4A 2 Fig 16 Cycle rate adjustment SETTINGAND ADJUSTMENTS Adjus...

Страница 7: ...mostat from the wall and install three new AA alkaline batteries We recommend Energizer batteries Change batteries within approximately 30 seconds from the time the batteries are removed to prevent program loss and the necessity to reprogram IMPORTANT The low battery warning will be displayed about two months before the batteries are dead When the batteries are dead the system will shut down After...

Страница 8: ...system switch to COOL and the fan switch to AUTO Press COOLER key until the setting is about 10 F 6 C below room temperature The cooling equipment and fan should start Press the WARMER key until the setting is about 10 F 6 C above room temperature The cooling equipment and fan should stop NOTE On an AUTO changeover thermostat T8602D the heating temperature must be set at least 3 F 2 C below the co...

Страница 9: ...e fan switch is in AUTO A HEAT displayed when system switch is in HEAT COOL when in COOL HEAT and COOL when in AUTO neither when in OFF Also a four digit code is displayed with each digit explained as follows m 1 m A This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations CRC c 1374 First Digit Cycle Rate Setting cph At 50 On Time 0 or 1 1 2 or 3 3...

Страница 10: ...69 0309 9 10 T8602A B C D AND TS8602A C Chronotherm III FUEL SAVER THERMOSTATS ...

Страница 11: ...69 0309 9 11 T8602A B C D AND TS8602A C Chronotherm III FUEL SAVER THERMOSTATS ...

Страница 12: ... and Building Control Honeywell Limited Honeywell Limitée 740 Ellesmere Road Scarborough Ontario M1P 2V9 Helping You Control Your World 69 0309 9 J H Rev 7 95 Printed in Taiwan R O C QUALITY IS KEY Home and Building Control Honeywell Inc 1985 Douglas Drive North Golden Valley MN 55422 ...

Отзывы: